New Study Identifies Impact of Sample Processing on Sensitivity of Rapid Antigen Detection Tests for SARS-CoV-2

By LabMedica International staff writers
Posted on 07 Dec 2021
Illustration
Illustration

A new study aimed at identifying the impact of sample processing on the sensitivity of rapid antigen detection (RAD) tests for SARS-CoV-2 has shown that selecting the appropriate inactivation methods and viral transport media (VTM) solutions is necessary during reagent development, performance evaluation, and clinical application.

The study published by the Chinese Medical Association (Beijing, China) explored the effect of different inactivation methods, VTM solutions, and sample preservation on the sensitivity of four RAD kits based on two SARS-CoV-2 strains. According to the results, heat inactivation may not be a suitable inactivation method for SARS-CoV-2 testing, especially for clinical testing and performance evaluation. This finding was consistent with a previous study reporting that heat inactivation harmed the efficiency of RT-PCR assay for SARS-CoV-2. Heat inactivation could be one of the possible factors of false-negative results in the RT-PCR assay of SARS-CoV-2 detection. Heat inactivation destroys the structure of the RNA and protein of SARS-CoV-2. RT-PCR assay can detect the nucleotide of SARS-CoV-2, while the RAD test can detect the antigen of SARS-CoV-2. Thus, heat inactivation could substantially affect the sensitivity of RAD kits.

Chemical inactivators might contribute a lot in protecting the laboratory personnel in charge of detecting SARS-CoV-2, especially nucleic acid detection because chemical inactivation can inactivate clinical samples containing SARS-CoV-2. Similarly, there might be some chemicals existing in VTMs that can denature and inactivate protein, thus affecting the performance of RAD kits. The VTM solution's impact on the RAD kits might be mainly conferred by the detection antibodies used in the kits, which utilize different epitopes to recognize the antigens in other kits. During sample inactivation, the VTM solution might change the tertiary structure of the antigen in the sample and cause it to degrade. Thus, the recognition between antigen and detection antibodies in the following detection process might greatly vary. Therefore, the reaction of different reagents to the same VTM was different, indicating that choosing the appropriate VTM solutions for RAD testing is necessary.

Additionally, the results showed that, along with the extension of preservation time and the increase of freeze–thaw cycles, the detection value of RAD kits slightly decreased, but most of them were still in the range of detection. A previous study had shown that the copy number of the DNA target decreased after 10 freeze-thaw cycles, which affected the performance of the droplet digital PCR. Also, there was no access to HIV viral load testing when the whole blood was stored in EDTA tubes or plasma preparation tubes for more than 6 h at 25 °C. Therefore, reasonable storage temperature and preservation time of samples are essential measures to ensure the accuracy of test results.

Thus, the study revealed that different virus inactivation methods and VTM solutions significantly impact the sensitivity of RAD kits. Therefore, it is necessary to select the appropriate inactivation methods and VTM solutions. Furthermore, as most RAD kits remain stable under different storage conditions, it is not required to consider the samples' preservation conditions. According to the results, during reagent development, performance evaluation, and clinical application, samples should not be treated by heat inactivation or unqualified VTM solutions before evaluating the performance of clinical samples, such as the lowest detection limitation. Moreover, samples should not be treated by heat inactivation or unqualified VTM solutions in clinical trials. In addition, attention should also be given to the warnings of the approved reagents, such as sample collection and preservation. To sum up, selecting VTM solutions might be more convenient, as they can effectively crack and inactivate viruses without affecting antigen testing.

Related Links:
Chinese Medical Association 

Gold Member
SARS-CoV-2 Reactive & Non-Reactive Controls
Qnostics SARS-CoV-2 Typing
POC Helicobacter Pylori Test Kit
Hepy Urease Test
ESR Analyzer
TEST1 2.0
Laboratory Software
ArtelWare

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more