Accuracy of Self-Sampling for HPV Screening Evaluated

By LabMedica International staff writers
Posted on 13 Feb 2019
Image: An Evalyn Brush used for patient self-sampling of the cervico-vaginal area (Photo courtesy of Rovers Medical Devices).
Image: An Evalyn Brush used for patient self-sampling of the cervico-vaginal area (Photo courtesy of Rovers Medical Devices).
Molecular testing for human papillomavirus (HPV) using patient-collected cervico-vaginal samples has shown similar levels of accuracy to testing done on clinician-collected samples and could boost participation in overall HPV screening.

Detecting cancer lesions in women who periodically attend clinics can be more difficult than detecting them in underscreened women who have rarely or never been screened, or have refused to attend clinics following an invitation from a screening organization.

Scientists at the Vrije Universiteit (Amsterdam, the Netherlands) examined 7,643 women aged 29 to 61 years in a self-sampling group and 6,282 in a clinician-collected sampling group. The primary endpoints of the study were detection of cervical intraepithelial neoplasia of grade 2 and worse or grade 3 and worse (CIN2+ or CIN3+). The women were requested to collect their own cervicovaginal sample using an Evalyn Brush; or a clinician-based sampling group, in which samples were collected by a general practitioner with a Cervex-Brush also from Rovers Medical Devices BV.

All samples were tested for HPV using the clinically validated GP5+/6+ PCR enzyme immunoassay. HPV-positive women in both groups were retested with the other collection method and triaged by cytology and repeat cytology in accordance with current Dutch screening guidelines. Of the self-collecting patients, 569, or 7.4%, tested positive for HPV, while in the physician-collected group, 451, or 7.2% tested positive. The CIN2+ sensitivity and specificity of HPV testing did not differ between the two groups, while CIN3+ relative sensitivity was 0.99 with essentially equivalent specificity.

The authors concluded that HPV testing done with a clinically validated PCR-based assay had similar accuracy on self-collected and clinician-collected samples in terms of the detection of CIN2+ or CIN3+ lesions. These findings suggest that HPV self-sampling could be used as a primary. Johannes Berkhof, PhD, a professor and a co-author of the study, said, “"Self-collection has potential to become a first screening test in many different countries. It creates a high participation rate, which is difficult to achieve. We have cleared the first hurdle, but now we need to see how we can implement this kind of screening.” The study was published on January 15, 2019, in the journal Lancet Oncology.

Related Links:
Vrije Universiteit

Gold Member
Collection and Transport System
PurSafe Plus®
POC Helicobacter Pylori Test Kit
Hepy Urease Test
New
Gold Member
Clinical Drug Testing Panel
DOA Urine MultiPlex
8-Channel Pipette
SAPPHIRE 20–300 µL

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more