Methods Discriminate Dengue Severity during Acute Infection

By LabMedica International staff writers
Posted on 03 Sep 2018
Image: The Panbio Dengue Duo Cassette can detect the high levels of IgG characteristic of secondary infections and IgM levels associated with primary dengue with high sensitivity and specificity (Photo courtesy of Alere).
Image: The Panbio Dengue Duo Cassette can detect the high levels of IgG characteristic of secondary infections and IgM levels associated with primary dengue with high sensitivity and specificity (Photo courtesy of Alere).
Dengue is the most widely distributed mosquito-borne human viral disease and represents a major public health burden globally. An estimated 390 million infections occur each year, of which around 100 million are symptomatic.

Although prior infection with another viral serotype, such as secondary dengue, is known to be an important factor influencing disease severity, current methods to determine primary versus secondary immune status during the acute illness do not consider the rapidly evolving immune response, and their accuracy has rarely been evaluated against an independent gold standard.

An international team led working at the Hospital for Tropical Diseases (Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam) enrolled 293 laboratory confirmed dengue patients aged 5 to 25 years who had registered in one of several clinical studies carried out at the Hospital for Tropical Diseases. Daily plasma samples obtained during the acute illness were assayed using the Panbio anti-dengue indirect immunoglobulin-G (IgG) enzyme-linked immunosorbent assay (ELISA), as well as in-house anti-dengue IgG and IgM capture ELISAs. Plaque reduction neutralization tests (PRNTs) were performed six months after the acute illness episode to define immune status.

The scientists reported that cut-offs derived for the various parameters demonstrated progressive change (positively or negatively) by day of illness. Using these time varying cut-offs it was possible to determine whether an infection was primary or secondary on single specimens, with acceptable performance. The model using Panbio Indirect IgG responses and including an interaction with illness day showed the best performance throughout, although with some decline in performance later in infection. Models based on in-house capture IgG levels, and the IgM/IgG ratio, also performed well, though conversely performance improved later in infection.

The authors concluded that for all assays, the best fitting models estimated a different cut-off value for different days of illness, confirming how rapidly the immune response changes during acute dengue. The optimal choice of assay will vary depending on circumstance. Although the Panbio Indirect IgG model performs best early on, the IgM/IgG capture ratio may be preferred later in the illness course. The study was published on August 7, 2018, in the journal BMC Infectious Diseases.

Related Links:
Hospital for Tropical Diseases

Gold Member
Quality Control Material
iPLEX Pro Exome QC Panel
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Homocysteine Quality Control
Liquichek Homocysteine Control
8-Channel Pipette
SAPPHIRE 20–300 µL

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more