Membrane Filters Compared for Isolation of Campylobacter

By LabMedica International staff writers
Posted on 18 Jul 2013
Image: Filter Electron Microscopy of Campylobacter jejuni (Photo courtesy of Louise Salt).
Image: Filter Electron Microscopy of Campylobacter jejuni (Photo courtesy of Louise Salt).
Several isolation methodologies have been developed for Campylobacter spp., and in order to have an effective isolation of C. jejuni and C. coli from feces, the culture media must be selective.

Some species of Campylobacter, like C. concisus, as well as Arcobacter spp. may be susceptible to the antibiotics in the modified Charcoal Cefoperazone Deoxycholate Agar (mCCDA) media, and the diagnosis may consequently be missed if a passive filtration technique is not performed.

Microbiologists at the Aalborg University Hospital (Denmark) evaluated the filtration technique by comparing two different filters, a polycarbonate (PC) membrane filter and a cellulose acetate (CA) membrane filter for isolation of Campylobacter spp., especially C. concisus. The study was conducted from February 2012 until June 2012, and 1,791 diarrheic stool samples from 1,377 patients were cultivated for enteric pathogenic bacteria.

Fecal samples were applied to two filters, a PC filter with a diameter of 47 mm and a 0.60-μm pore size (Nuclepore, Whatman; Maidstone, Kent, UK), and a CA filter with a diameter of 50 mm and a 0.65 μm pore size (Sartorius AG; Gottingen, Germany). Each filter was placed on the surface of a 5% yeast-enriched blood agar plates (SSI [Statens Serum Institut] Diagnostica; Hillerød, Denmark). After filtration, the filters were carefully removed with sterile forceps and discarded and the culture plates were incubated at 37 °C.

C. jejuni and C. coli were the only species of bacteria that grew on the mCCDA medium. The scientists found a significantly higher prevalence of 114 C. concisus with use of the PC filter compared to 79 with the CA filter, even though the PC filter had a smaller diameter as well as a smaller pore size. The authors concluded that the filtration technique should not be used as a replacement for the mCCDA, but that their results imply that the filtration technique works well for the isolation for all Campylobacter spp. They found that the filter technique easy to handle in the routine laboratory and recommend the use of the PC filter instead of the commonly used CA filter when culture for Campylobacter is performed. The study was published on June 3, 2013, in the journal Diagnostic Microbiology and Infectious Disease.

Related Links:

Aalborg University Hospital
Whatman
Sartorius AG



Gold Member
Blood Gas Analyzer
Stat Profile pHOx
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Homocysteine Quality Control
Liquichek Homocysteine Control
6 Part Hematology Analyzer with RET + IPF
Mispa HX 88

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more