We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Recombinant Antigens Assessed for Serological Diagnosis of Syphilis

By LabMedica International staff writers
Posted on 09 Aug 2022
Image: Photomicrograph of Treponema pallidum bacterial spirochetes, which exhibited their characteristic corkscrew shape using the dark field visualization technique (Photo courtesy of Louisa Lu, MD)
Image: Photomicrograph of Treponema pallidum bacterial spirochetes, which exhibited their characteristic corkscrew shape using the dark field visualization technique (Photo courtesy of Louisa Lu, MD)

Syphilis is a chronic multisystemic disease caused by infection with the spirochete Treponema pallidum and acquired usually via sexual exposure or via vertical mother–fetus transmission or by blood transfusions. An estimated 18 million cases worldwide and 5.6 million new cases occur annually.

Currently, diagnosis remains primarily dependent on serologic tests due to the inability to culture T. pallidum in vitro. The serological tests for the diagnosis of syphilis are divided into non-treponemal tests and treponemal tests. Some of these tests are expensive, labor-intensive, time-consuming, highly operator-dependent, and not suitable for high-volume screening.

Biomedical Scientists at the Hengyang Medical School (Hengyang, China) and their colleagues collected human serum samples from patients with clinically diagnosed primary (n = 21), secondary (n = 78), latent (n = 228), and tertiary (n = 13) syphilis, healthy controls (n = 60), and hepatitis B (n = 56), tuberculosis (n = 20), rheumatoid arthritis (RA) (n = 40), systemic lupus erythematosus (SLE) (n = 40), between March 2019 and August 2020.

Two recombinant T. pallidum proteins Tp0100 and Tp1016 were expressed, purified, and identified by Western Blotting. A total of 600 clinical serum samples were tested with the Tp0100-based ELISA, the Tp1016-based ELISA, and the commercial LICA Syphilis TP kit (CHIVD Chemclin Diagnostics Corporation, Beijing, China). The sensitivities were determined by testing 340 samples from individuals with clinically diagnosed primary, secondary, latent, and tertiary syphilis. The specificities were determined by screening 260 samples from healthy controls and individuals with potentially cross-reactive infections. The team also performed indirect IgG enzyme-linked immunosorbent assays and light-initiated chemiluminescent assays (LICA).

The scientists used clinical syphilis diagnosis as the gold standard, Tp0100 exhibited an overall sensitivity of 95.6% and specificity of 98.1% for testing IgG antibody while Tp1016 demonstrated only an overall sensitivity of 75.0% and specificity of 79.6%. In contrast, the LICA Syphilis TP test revealed an overall sensitivity of 97.6% and specificity of 96.2%. In addition, the overall percent agreement and corresponding κ values were 96.7% (95% CI 95.6%–97.8%) and 0.93% for the Tp0100-based ELISA, 77.0% (95% CI 74.3%–79.7%) and 0.54% for the Tp1016-based ELISA, and 97.0% (95% CI 96.0%–98.0%) and 0.94 for the LICA Syphilis TP test, respectively.

The authors concluded that the recombinant T. pallidum protein Tp0100 showed promise as a novel diagnostic antigen in the serological tests for syphilis. The study was published on July 31 2022 in the Journal of Clinical Laboratory Analysis.

Related Links:
Hengyang Medical School 
CHIVD Chemclin Diagnostics Corporation 

Gold Member
Immunochromatographic Assay
CRYPTO Cassette
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gel Cards
DG Gel Cards
Capillary Blood Collection Tube
IMPROMINI M3

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more