A Novel Lateral Flow Immunoassay System for Determination of Prostate Specific Antigen
By LabMedica International staff writers Posted on 10 Jan 2022 |

Image: Human prostate specific antigen (PSA) with bound substrate from complex with antibody (Photo courtesy of Wikimedia Commons)
A recent paper described the development of a highly portable quantitative screening test for prostate cancer.
Prostate cancer (PCa) is the second most diagnosed cancer among men. Prostate-specific antigen (PSA) is the most reliable and widely accepted tumor biomarker for screening and monitoring of PCa status. PSA is present in small quantities in the serum of men with healthy prostates, but is often elevated in the presence of prostate cancer or other prostate disorders. It is a 34,000 Dalton glycoprotein produced almost exclusively by the prostate gland. PSA is a serine protease enzyme, the gene of which is located on the 19th chromosome.
Since quantification of serum PSA requires access to centralized laboratories, which may not be available in developing countries, investigators at Cornell University (Ithaca, NY, USA) developed a rapid test system including a highly portable strip reader for off-site quantification of total PSA from a drop of serum within 20 minutes.
The system was based on the lateral flow immunoassay (LFIA) method. LFIA-based tests have been coupled with smartphones and battery powered portable readers for imaging the test strips at the point of care. Lateral flow test strips rely on capillary flow within a nitrocellulose membrane without need for external pump or moving components to control the flow. However, at present, [U.S.] FDA approved LFIA for PSA is not commercially available.
The most common nanoparticles used in commercial LFIAs are 40 nanometer gold nanospheres due to their optimal combination of high contrast color (absorption at about 523 nanometers) with distinct cherry red color for visual readouts and surface area suitable for targeting analytes of a wide range of sizes. In the current study, the investigators compared the performance of gold nanoshells with the widely used, industry standard 40 nanometer gold nanospheres.
The structure of gold nanoshells consists of 110 nanometer core silica spheres with a thin (12–18 nanometer) gold shell deposited over them. The silica core reduces the overall particle density relative to a solid gold nanosphere of same size, allowing for improved flow rates through a lateral flow membrane compared to a 150 nanometer solid gold sphere. Gold nanoshells produce a high contrast blue-grey line that is clearly visible.
The investigators first optimized and evaluated the performance of the assay with commercially available total PSA calibrators. On initial validation with a commercially available PSA calibrator, a detection range of 0.5–150 nanograms/milliLiter was achieved. They then compared the performance of the total PSA LFIA test with the Siemens-Healthineers (Erlangen, Germany) IMMULITE analyzer for quantification of total PSA in archived human serum samples.
Results revealed that the use of gold nanoshells as a label for the lateral flow assay increased the measured colorimetric signal intensity and achieved a five times lower detection limit when compared to the traditionally used 40 nanometer gold nanosphere labels. This increased sensitivity yielded results for archived serum samples that demonstrated greater than 0.95 correlation between the rapid LFIA test and the IMMULITE analyzer.
“We will be able to take a drop of blood in a community setting such as a barbershop and be able to deliver results in 10 to 15 minutes right there, which can indicate when somebody needs to come in for further tests,” said senior author Dr. Saurabh Mehta, professor of nutritional sciences at Cornell University. “It is creating that first point of contact that hopefully builds rapport and brings health care services to the people at the point of need,”
The rapid LFIA for measurement of PSA was described in the November 14, 2021, online edition of the journal Current Research in Biotechnology.
Related Links:
Cornell University
Siemens-Healthineers
Prostate cancer (PCa) is the second most diagnosed cancer among men. Prostate-specific antigen (PSA) is the most reliable and widely accepted tumor biomarker for screening and monitoring of PCa status. PSA is present in small quantities in the serum of men with healthy prostates, but is often elevated in the presence of prostate cancer or other prostate disorders. It is a 34,000 Dalton glycoprotein produced almost exclusively by the prostate gland. PSA is a serine protease enzyme, the gene of which is located on the 19th chromosome.
Since quantification of serum PSA requires access to centralized laboratories, which may not be available in developing countries, investigators at Cornell University (Ithaca, NY, USA) developed a rapid test system including a highly portable strip reader for off-site quantification of total PSA from a drop of serum within 20 minutes.
The system was based on the lateral flow immunoassay (LFIA) method. LFIA-based tests have been coupled with smartphones and battery powered portable readers for imaging the test strips at the point of care. Lateral flow test strips rely on capillary flow within a nitrocellulose membrane without need for external pump or moving components to control the flow. However, at present, [U.S.] FDA approved LFIA for PSA is not commercially available.
The most common nanoparticles used in commercial LFIAs are 40 nanometer gold nanospheres due to their optimal combination of high contrast color (absorption at about 523 nanometers) with distinct cherry red color for visual readouts and surface area suitable for targeting analytes of a wide range of sizes. In the current study, the investigators compared the performance of gold nanoshells with the widely used, industry standard 40 nanometer gold nanospheres.
The structure of gold nanoshells consists of 110 nanometer core silica spheres with a thin (12–18 nanometer) gold shell deposited over them. The silica core reduces the overall particle density relative to a solid gold nanosphere of same size, allowing for improved flow rates through a lateral flow membrane compared to a 150 nanometer solid gold sphere. Gold nanoshells produce a high contrast blue-grey line that is clearly visible.
The investigators first optimized and evaluated the performance of the assay with commercially available total PSA calibrators. On initial validation with a commercially available PSA calibrator, a detection range of 0.5–150 nanograms/milliLiter was achieved. They then compared the performance of the total PSA LFIA test with the Siemens-Healthineers (Erlangen, Germany) IMMULITE analyzer for quantification of total PSA in archived human serum samples.
Results revealed that the use of gold nanoshells as a label for the lateral flow assay increased the measured colorimetric signal intensity and achieved a five times lower detection limit when compared to the traditionally used 40 nanometer gold nanosphere labels. This increased sensitivity yielded results for archived serum samples that demonstrated greater than 0.95 correlation between the rapid LFIA test and the IMMULITE analyzer.
“We will be able to take a drop of blood in a community setting such as a barbershop and be able to deliver results in 10 to 15 minutes right there, which can indicate when somebody needs to come in for further tests,” said senior author Dr. Saurabh Mehta, professor of nutritional sciences at Cornell University. “It is creating that first point of contact that hopefully builds rapport and brings health care services to the people at the point of need,”
The rapid LFIA for measurement of PSA was described in the November 14, 2021, online edition of the journal Current Research in Biotechnology.
Related Links:
Cornell University
Siemens-Healthineers
Latest Molecular Diagnostics News
- D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism
- New Biomarkers to Improve Early Detection and Monitoring of Kidney Injury
- Chemiluminescence Immunoassays Support Diagnosis of Alzheimer’s Disease
- Blood Test Identifies Multiple Biomarkers for Rapid Diagnosis of Spinal Cord Injury
- Highly Accurate Blood Test Diagnoses Alzheimer’s and Measures Dementia Progression
- Simple DNA PCR-Based Lab Test to Enable Personalized Treatment of Bacterial Vaginosis
- Rapid Diagnostic Test to Halt Mother-To-Child Hepatitis B Transmission
- Simple Urine Test Could Help Patients Avoid Invasive Scans for Kidney Cancer
- New Bowel Cancer Blood Test to Improve Early Detection
- Refined Test Improves Parkinson’s Disease Diagnosis
- New Method Rapidly Diagnoses CVD Risk Via Molecular Blood Screening
- Blood Test Shows Promise for Early Detection of Dementia
- CRISPR-Based Diagnostic Test Detects Pathogens in Blood Without Amplification
- Portable Blood-Based Device Detects Colon Cancer
- New DNA Test Diagnoses Bacterial Infections Faster and More Accurately
- Innovative Bio-Detection Platform Improves Early Cancer Screening and Monitoring
Channels
Clinical Chemistry
view channel
Carbon Nanotubes Help Build Highly Accurate Sensors for Continuous Health Monitoring
Current sensors can measure various health indicators, such as blood glucose levels, in the body. However, there is a need to develop more accurate and sensitive sensor materials that can detect lower... Read more
Paper-Based Device Boosts HIV Test Accuracy from Dried Blood Samples
In regions where access to clinics for routine blood tests presents financial and logistical obstacles, HIV patients are increasingly able to collect and send a drop of blood using paper-based devices... Read moreHematology
view channel
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read more
Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
In the United States, approximately 15% of pregnant individuals are RhD-negative. However, in about 40% of these cases, the fetus is also RhD-negative, making the administration of RhoGAM unnecessary.... Read moreImmunology
view channel
Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions
In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read moreCerebrospinal Fluid Test Predicts Dangerous Side Effect of Cancer Treatment
In recent years, cancer immunotherapy has emerged as a promising approach where the patient's immune system is harnessed to fight cancer. One form of immunotherapy, called CAR-T-cell therapy, involves... Read more
New Test Measures Preterm Infant Immunity Using Only Two Drops of Blood
Preterm infants are particularly vulnerable due to their organs still undergoing development, which can lead to difficulties in breathing, eating, and regulating body temperature. This is especially true... Read more
Simple Blood Test Could Help Choose Better Treatments for Patients with Recurrent Endometrial Cancer
Endometrial cancer, which develops in the lining of the uterus, is the most prevalent gynecologic cancer in the United States, affecting over 66,000 women annually. Projections indicate that in 2025, around... Read moreMicrobiology
view channel
Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours
Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read moreInnovative ID/AST System to Help Diagnose Infectious Diseases and Combat AMR
Each year, 11 million people across the world die of sepsis out of which 1.3 million deaths are due to antibiotic-resistant bacteria. The burden of antimicrobial resistance (AMR) continues to weigh heavily,... Read more
Gastrointestinal Panel Delivers Rapid Detection of Five Common Bacterial Pathogens for Outpatient Use
Acute infectious gastroenteritis results in approximately 179 million cases each year in the United States, leading to a significant number of outpatient visits and hospitalizations. To address this, a... Read morePathology
view channel
AI Model Predicts Patient Response to Bladder Cancer Treatment
Each year in the United States, around 81,000 new cases of bladder cancer are diagnosed, leading to approximately 17,000 deaths annually. Muscle-invasive bladder cancer (MIBC) is a severe form of bladder... Read more
New Laser-Based Method to Accelerate Cancer Diagnosis
Researchers have developed a method to improve cancer diagnostics and other diseases. Collagen, a key structural protein, plays various roles in cell activity. A novel multidisciplinary study published... Read more
New AI Model Predicts Gene Variants’ Effects on Specific Diseases
In recent years, artificial intelligence (AI) has greatly enhanced our ability to identify a vast number of genetic variants in increasingly larger populations. However, up to half of these variants are... Read more
Powerful AI Tool Diagnoses Coeliac Disease from Biopsy Images with Over 97% Accuracy
Coeliac disease is an autoimmune disorder triggered by the consumption of gluten, causing symptoms such as stomach cramps, diarrhea, skin rashes, weight loss, fatigue, and anemia. Due to the wide variation... Read moreTechnology
view channel
Smartphones Could Diagnose Diseases Using Infrared Scans
Rapid advancements in technology may soon make it possible for individuals to bypass invasive medical procedures by simply uploading a screenshot of their lab results from their phone directly to their doctor.... Read more
Novel Sensor Technology to Enable Early Diagnoses of Metabolic and Cardiovascular Disorders
Metabolites are critical compounds that fuel life's essential functions, playing a key role in producing energy, regulating cellular activities, and maintaining the balance of bodily systems.... Read more
3D Printing Breakthrough Enables Large Scale Development of Tiny Microfluidic Devices
Microfluidic devices are diagnostic systems capable of analyzing small volumes of materials with precision and speed. These devices are used in a variety of applications, including cancer cell analysis,... Read moreIndustry
view channel
Tecan Acquires ELISA Immunoassay Assets from Revvity's Cisbio Bioassays
Tecan Group (Männedorf, Switzerland) has entered into an agreement to acquire certain assets relating to key ELISA immunoassay products from Cisbio Bioassays SAS (Codolet, France), a subsidiary of the... Read more