Toxoplasmosis Immune Status in Pregnancy Determined by Immunochromatography Assay
|
By LabMedica International staff writers Posted on 30 Mar 2021 |

Image: TOXOPLASMA ICT IgG-IgM is a unitary qualitative rapid test based on the immune chromatography technology (lateral flow), allowing the simultaneous detection of both IgG and IgM class anti-Toxoplasma antibodies in human sera (Photo courtesy of LDBIO DIAGNOSTICS)
Toxoplasmosis is a disease that results from infection with the Toxoplasma gondii parasite, one of the world's most common parasites. Infection usually occurs by eating undercooked contaminated meat, exposure from infected cat feces, or mother-to-child transmission during pregnancy.
Obstetrical toxoplasmosis involves the systematic serological screening for Toxoplasma‐specific IgG and IgM antibodies which is usually performed using enzyme-linked immunosorbent assay (ELISA) techniques. Screening tests used routinely are not sufficient and require additional techniques to determine the Toxoplasma immune status.
Medical Parasitologists at the Pasteur Institute of Tunis (Tunis, Tunisia) selected 39 sera collected during the period 2015 to 2018 in the setting of the routine Toxoplasma serological screening in pregnant women. Sera were selected according to their anti‐Toxoplasma IgM and IgG antibodies titers in “Platelia Toxo IgG, IgM” (Bio-Rad, Marnes-la-Coquette, France).
Western blot Toxo II IgG (LDBIO DIAGNOSTICS, Lyon, France) was performed for all the sera in order to precisely determine their exact Toxoplasma immune status. The LDBIO Toxoplasma ICT IgG‐IgM is a rapid, simple, qualitative test based on immunochromatography technology (ICT, lateral flow). A positive test reveals the presence of anti‐Toxoplasma antibodies, but does not distinguish between IgG and IgM classes.
The scientists reported that in the absence of IgM and presence of IgG equivocal titers in ELISA, Toxoplasma ICT IgG‐IgM and WB Toxo II results were 94.7% concordant. All positive samples in WB were also positive in ICT. The sensitivity in the detection either of low IgG titers in absence of IgM or of specific anti‐Toxoplasma IgM was 100%. Only one serum with equivocal IgG titer by ELISA and negative with Toxo II IgG test revealed positive in ICT. However, this serum showed a P30 band in WB analysis. On the other hand, three sera positive in ELISA IgM and negative in ELISA IgG revealed positive in ICT and negative in WB Toxo II IgG, the reference test.
The authors concluded that their results confirm the high sensitivity of Toxoplasma ICT IgG‐IgM in detecting both specific anti‐Toxoplasma IgG and IgM, and highlight the usefulness of this rapid test as a first or second‐line Toxoplasma serological test in pregnant women. The study was published on March 15, 2021 in the Journal of Clinical Laboratory Analysis.
Related Links:
Pasteur Institute of Tunis
Bio-Rad
LDBIO DIAGNOSTICS
Obstetrical toxoplasmosis involves the systematic serological screening for Toxoplasma‐specific IgG and IgM antibodies which is usually performed using enzyme-linked immunosorbent assay (ELISA) techniques. Screening tests used routinely are not sufficient and require additional techniques to determine the Toxoplasma immune status.
Medical Parasitologists at the Pasteur Institute of Tunis (Tunis, Tunisia) selected 39 sera collected during the period 2015 to 2018 in the setting of the routine Toxoplasma serological screening in pregnant women. Sera were selected according to their anti‐Toxoplasma IgM and IgG antibodies titers in “Platelia Toxo IgG, IgM” (Bio-Rad, Marnes-la-Coquette, France).
Western blot Toxo II IgG (LDBIO DIAGNOSTICS, Lyon, France) was performed for all the sera in order to precisely determine their exact Toxoplasma immune status. The LDBIO Toxoplasma ICT IgG‐IgM is a rapid, simple, qualitative test based on immunochromatography technology (ICT, lateral flow). A positive test reveals the presence of anti‐Toxoplasma antibodies, but does not distinguish between IgG and IgM classes.
The scientists reported that in the absence of IgM and presence of IgG equivocal titers in ELISA, Toxoplasma ICT IgG‐IgM and WB Toxo II results were 94.7% concordant. All positive samples in WB were also positive in ICT. The sensitivity in the detection either of low IgG titers in absence of IgM or of specific anti‐Toxoplasma IgM was 100%. Only one serum with equivocal IgG titer by ELISA and negative with Toxo II IgG test revealed positive in ICT. However, this serum showed a P30 band in WB analysis. On the other hand, three sera positive in ELISA IgM and negative in ELISA IgG revealed positive in ICT and negative in WB Toxo II IgG, the reference test.
The authors concluded that their results confirm the high sensitivity of Toxoplasma ICT IgG‐IgM in detecting both specific anti‐Toxoplasma IgG and IgM, and highlight the usefulness of this rapid test as a first or second‐line Toxoplasma serological test in pregnant women. The study was published on March 15, 2021 in the Journal of Clinical Laboratory Analysis.
Related Links:
Pasteur Institute of Tunis
Bio-Rad
LDBIO DIAGNOSTICS
Latest Microbiology News
- Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease
- AI-Powered Platform Enables Rapid Detection of Drug-Resistant C. Auris Pathogens
- New Test Measures How Effectively Antibiotics Kill Bacteria
- New Antimicrobial Stewardship Standards for TB Care to Optimize Diagnostics
- New UTI Diagnosis Method Delivers Antibiotic Resistance Results 24 Hours Earlier
- Breakthroughs in Microbial Analysis to Enhance Disease Prediction
- Blood-Based Diagnostic Method Could Identify Pediatric LRTIs
- Rapid Diagnostic Test Matches Gold Standard for Sepsis Detection
- Rapid POC Tuberculosis Test Provides Results Within 15 Minutes
- Rapid Assay Identifies Bloodstream Infection Pathogens Directly from Patient Samples
- Blood-Based Molecular Signatures to Enable Rapid EPTB Diagnosis
- 15-Minute Blood Test Diagnoses Life-Threatening Infections in Children
- High-Throughput Enteric Panels Detect Multiple GI Bacterial Infections from Single Stool Swab Sample
- Fast Noninvasive Bedside Test Uses Sugar Fingerprint to Detect Fungal Infections
- Rapid Sepsis Diagnostic Device to Enable Personalized Critical Care for ICU Patients
- Microfluidic Platform Assesses Neutrophil Function in Sepsis Patients
Channels
Clinical Chemistry
view channel
New PSA-Based Prognostic Model Improves Prostate Cancer Risk Assessment
Prostate cancer is the second-leading cause of cancer death among American men, and about one in eight will be diagnosed in their lifetime. Screening relies on blood levels of prostate-specific antigen... Read more
Extracellular Vesicles Linked to Heart Failure Risk in CKD Patients
Chronic kidney disease (CKD) affects more than 1 in 7 Americans and is strongly associated with cardiovascular complications, which account for more than half of deaths among people with CKD.... Read moreMolecular Diagnostics
view channel
Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test
Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more
Blood Test Detects Early-Stage Cancers by Measuring Epigenetic Instability
Early-stage cancers are notoriously difficult to detect because molecular changes are subtle and often missed by existing screening tools. Many liquid biopsies rely on measuring absolute DNA methylation... Read more
“Lab-On-A-Disc” Device Paves Way for More Automated Liquid Biopsies
Extracellular vesicles (EVs) are tiny particles released by cells into the bloodstream that carry molecular information about a cell’s condition, including whether it is cancerous. However, EVs are highly... Read more
Blood Test Identifies Inflammatory Breast Cancer Patients at Increased Risk of Brain Metastasis
Brain metastasis is a frequent and devastating complication in patients with inflammatory breast cancer, an aggressive subtype with limited treatment options. Despite its high incidence, the biological... Read moreHematology
view channel
New Guidelines Aim to Improve AL Amyloidosis Diagnosis
Light chain (AL) amyloidosis is a rare, life-threatening bone marrow disorder in which abnormal amyloid proteins accumulate in organs. Approximately 3,260 people in the United States are diagnosed... Read more
Fast and Easy Test Could Revolutionize Blood Transfusions
Blood transfusions are a cornerstone of modern medicine, yet red blood cells can deteriorate quietly while sitting in cold storage for weeks. Although blood units have a fixed expiration date, cells from... Read more
Automated Hemostasis System Helps Labs of All Sizes Optimize Workflow
High-volume hemostasis sections must sustain rapid turnaround while managing reruns and reflex testing. Manual tube handling and preanalytical checks can strain staff time and increase opportunities for error.... Read more
High-Sensitivity Blood Test Improves Assessment of Clotting Risk in Heart Disease Patients
Blood clotting is essential for preventing bleeding, but even small imbalances can lead to serious conditions such as thrombosis or dangerous hemorrhage. In cardiovascular disease, clinicians often struggle... Read moreMicrobiology
view channel
Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease
Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read moreAI-Powered Platform Enables Rapid Detection of Drug-Resistant C. Auris Pathogens
Infections caused by the pathogenic yeast Candida auris pose a significant threat to hospitalized patients, particularly those with weakened immune systems or those who have invasive medical devices.... Read morePathology
view channel
Engineered Yeast Cells Enable Rapid Testing of Cancer Immunotherapy
Developing new cancer immunotherapies is a slow, costly, and high-risk process, particularly for CAR T cell treatments that must precisely recognize cancer-specific antigens. Small differences in tumor... Read more
First-Of-Its-Kind Test Identifies Autism Risk at Birth
Autism spectrum disorder is treatable, and extensive research shows that early intervention can significantly improve cognitive, social, and behavioral outcomes. Yet in the United States, the average age... Read moreTechnology
view channel
Robotic Technology Unveiled for Automated Diagnostic Blood Draws
Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more
ADLM Launches First-of-Its-Kind Data Science Program for Laboratory Medicine Professionals
Clinical laboratories generate billions of test results each year, creating a treasure trove of data with the potential to support more personalized testing, improve operational efficiency, and enhance patient care.... Read moreAptamer Biosensor Technology to Transform Virus Detection
Rapid and reliable virus detection is essential for controlling outbreaks, from seasonal influenza to global pandemics such as COVID-19. Conventional diagnostic methods, including cell culture, antigen... Read more
AI Models Could Predict Pre-Eclampsia and Anemia Earlier Using Routine Blood Tests
Pre-eclampsia and anemia are major contributors to maternal and child mortality worldwide, together accounting for more than half a million deaths each year and leaving millions with long-term health complications.... Read moreIndustry
view channelNew Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing
Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more
AI-Powered Cervical Cancer Test Set for Major Rollout in Latin America
Noul Co., a Korean company specializing in AI-based blood and cancer diagnostics, announced it will supply its intelligence (AI)-based miLab CER cervical cancer diagnostic solution to Mexico under a multi‑year... Read more
Diasorin and Fisher Scientific Enter into US Distribution Agreement for Molecular POC Platform
Diasorin (Saluggia, Italy) has entered into an exclusive distribution agreement with Fisher Scientific, part of Thermo Fisher Scientific (Waltham, MA, USA), for the LIAISON NES molecular point-of-care... Read more






 Analyzer.jpg)
