LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Immunochromatographic Test Rapidly Diagnoses Parasitic Infection

By LabMedica International staff writers
Posted on 15 Aug 2018
Image: Positive and negative results detected by the lateral flow immunochromatographic assay AcQuickDx test for Angiostrongylus cantonensis (Photo courtesy of Faculty of Medicine Siriraj Hospital).
Image: Positive and negative results detected by the lateral flow immunochromatographic assay AcQuickDx test for Angiostrongylus cantonensis (Photo courtesy of Faculty of Medicine Siriraj Hospital).
The rat lungworm Angiostrongylus cantonensis is a food-borne zoonotic parasite that causes eosinophilic meningitis in humans. Suspected cases of A. cantonensis infection can only be confirmed by finding the nematodes in cerebral spinal fluid (CSF) of the patients.

The serological diagnosis of human infection with Angiostrongylus cantonensis remains problematic because there are no commercially available validated tests. Most laboratories use domestically prepared tests such as the enzyme-linked immunosorbent assay (ELISA) or immunoblotting.

Scientists working with those at the Mahidol University (Bangkok, Thailand) assessed 97 serum samples: 19 samples from clinically diagnosed patients with detectable A. cantonensis-specific antibody in immunoblotting; 43 samples from patients with other parasitic diseases, such as gnathostomiasis, toxocariasis, trichinellosis, hookworm infection, filariasis, cysticercosis, paragonimiasis, opisthorchiasis, and malaria; and 35 samples from normal healthy subjects.

The test device was assembled with purified 31-kDa glycoprotein as diagnostic antigen and with gold-labeled anti-human immunoglobulin-G as the detector reagent. The team assessed the rapid lateral flow immunochromatographic assay designated AcQuickDx Test to detect anti-A. cantonensis antibodies in human sera. The appearance of a red band at the T line and a red band at the C line within 15 min indicates a positive reaction, whereas the absence of a red band at the T line and appearance of a red band at the C line indicates a negative reaction.

The team found that the sensitivity, specificity, positive predictive value and negative predictive value of AcQuickDx test to detect anti-A. cantonensis specific antibodies in serologically confirmed angiostrongyliasis cases were 100%, 98.72%, 95% and 100%, respectively. Positive AcQuickDx was observed in 1/4 cases with hookworm infections. No positive AcQuickDx was observed in cases with other parasitic diseases, and the individual healthy subjects.

The authors concluded that the AcQuickDx test is rapid, highly sensitive and specific, and easy to perform without additional equipment or ancillary supplies. It yields results that are interpreted visually, and possesses a long shelf life at room temperature. Thus, it can be applied as an additional test for clinical diagnostic support of angiostrongyliasis either in conventional laboratories or for remote areas where laboratory infrastructure is not available. The study was published in the August 2018 issue of the International Journal of Infectious Diseases.

Related Links:
Mahidol University

Gold Member
Immunochromatographic Assay
CRYPTO Cassette
POC Helicobacter Pylori Test Kit
Hepy Urease Test
6 Part Hematology Analyzer with RET + IPF
Mispa HX 88
Sample Transportation System
Tempus1800 Necto

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more