Hematology Analyzer Evaluated for Cerebrospinal Fluid Testing
|
By LabMedica International staff writers Posted on 04 Apr 2012 |
One of newest generation hybrid hematology analyzer is equipped with an improved body fluid analysis mode that is suitable for cerebrospinal fluid (CSF) analysis.
The cellular components of CSF have conventionally been enumerated microscopically by using a hemocytometer-counting chamber, but this is labor intensive and time consuming, and maybe replaced by a hematology autoanalyzer.
Laboratory scientists at the Medical University of Vienna (Austria) analyzed a total of 425 consecutive CSF samples sent to the Department of Laboratory Medicine for routine testing. Microscopic cell counts were performed by biomedical technicians using a Fuchs-Rosenthal counting chamber after samples were stained with methyl violet acetic acid.
CSF samples were measured for white blood cells (WBCs) using the body fluid mode of the XE-5000 Hematology Analyzer. By combining fluorescent dye binding and semiconductor laser technology, the XE-5000 (Sysmex Corporation; Kobe, Japan) differentiates between WBCs that are mononuclear cells (MN), including lymphocytes and monocytes and those that are polymorphonuclear cells (PMN), including all types of granulocytes.
For total WBC counts, the proportions of samples correctly classified by the XE-5000 from different groups were: 88% for 0 to 5 WBC/µL in 330 samples; 47% for 6 to10 WBC/µL in 36 samples; 72% for 11 to 50 WBC/µL in 39 samples; 93% for 51 to 200 WBC/µL in15 samples; and 100% for cell counts above 200 WBC/µL. After the two lowest count categories were combined into one range of 0 to10 WBC/µL, matches increased to 95%. For PMN counts in the 0% to 25% group, 37% of samples were misclassified by the XE-5000. Conversely, for samples with microscopic PMN counts of more than 25%, there was a trend toward underestimation by the XE-5000. Mismatches were most pronounced in samples with fewer than 10 WBC/µL.
The authors concluded that based on the results of their study, they felt confident in recommending the XE-5000 as a reliable WBC counter for CSF, even for samples with low WBC counts, which comprise most laboratory admissions. It was previously recommended that all samples with cell counts of less than 5 and more than 20 WBC/µL on the XE-5000 be manually recounted, but the authors propose selecting samples for microscopic rework based on their DIFF channel scattergrams rather than predefined WBC count results. However, it cannot be recommended as a suitable alternative for manual differential cytological workup. The study was published in the February 2012 edition of the journal Archives of Pathology & Laboratory Medicine.
Related Links:
Medical University of Vienna
Sysmex Corporation
The cellular components of CSF have conventionally been enumerated microscopically by using a hemocytometer-counting chamber, but this is labor intensive and time consuming, and maybe replaced by a hematology autoanalyzer.
Laboratory scientists at the Medical University of Vienna (Austria) analyzed a total of 425 consecutive CSF samples sent to the Department of Laboratory Medicine for routine testing. Microscopic cell counts were performed by biomedical technicians using a Fuchs-Rosenthal counting chamber after samples were stained with methyl violet acetic acid.
CSF samples were measured for white blood cells (WBCs) using the body fluid mode of the XE-5000 Hematology Analyzer. By combining fluorescent dye binding and semiconductor laser technology, the XE-5000 (Sysmex Corporation; Kobe, Japan) differentiates between WBCs that are mononuclear cells (MN), including lymphocytes and monocytes and those that are polymorphonuclear cells (PMN), including all types of granulocytes.
For total WBC counts, the proportions of samples correctly classified by the XE-5000 from different groups were: 88% for 0 to 5 WBC/µL in 330 samples; 47% for 6 to10 WBC/µL in 36 samples; 72% for 11 to 50 WBC/µL in 39 samples; 93% for 51 to 200 WBC/µL in15 samples; and 100% for cell counts above 200 WBC/µL. After the two lowest count categories were combined into one range of 0 to10 WBC/µL, matches increased to 95%. For PMN counts in the 0% to 25% group, 37% of samples were misclassified by the XE-5000. Conversely, for samples with microscopic PMN counts of more than 25%, there was a trend toward underestimation by the XE-5000. Mismatches were most pronounced in samples with fewer than 10 WBC/µL.
The authors concluded that based on the results of their study, they felt confident in recommending the XE-5000 as a reliable WBC counter for CSF, even for samples with low WBC counts, which comprise most laboratory admissions. It was previously recommended that all samples with cell counts of less than 5 and more than 20 WBC/µL on the XE-5000 be manually recounted, but the authors propose selecting samples for microscopic rework based on their DIFF channel scattergrams rather than predefined WBC count results. However, it cannot be recommended as a suitable alternative for manual differential cytological workup. The study was published in the February 2012 edition of the journal Archives of Pathology & Laboratory Medicine.
Related Links:
Medical University of Vienna
Sysmex Corporation
Latest Pathology News
- Uncertainty-Aware AI Platform Supports Automated HER2 Assessment in Breast Cancer
- AI Tool Speeds Brain Tumor Classification from Routine Histology Slides
- IHC Companion Diagnostic Standardizes Mismatch Repair Testing for Cancer Immunotherapy
- AI Pathology Tool Predicts Meningioma Recurrence from Routine Slides
- 3D Spatial Multi-Omics Maps Intra-Tumor Diversity in Colorectal Cancer
- Blood-Based Method Tracks Gene Activity in the Living Brain
- FDA Approval Expands Automated PD-L1 Testing Across Solid Tumors
- AI-Powered Atlas Maps Immune Structures Linked to Cancer Outcomes
- AI Tool Extracts Immune Signals from Biopsy to Inform Myeloma Therapy
- Rapid AI Tool Predicts Cancer Spatial Gene Expression from Pathology Images
- AI Pathology Test Receives FDA Breakthrough for Bladder Cancer Risk Stratification
- FDA Clears AI Digital Pathology Tool for Breast Cancer Risk Stratification
- New AI Tool Reveals Hidden Genetic Signals in Routine H&E Slides
- AI System Analyzes Routine Pathology Slides to Predict Cancer Outcomes
- New Tissue Mapping Approach Identifies High-Risk Form of Diabetic Kidney Disease
- Multimodal AI Tool Predicts Genetic Alterations to Guide Breast Cancer Treatment
Channels
Molecular Diagnostics
view channel
Ultrasensitive HPV Blood Test Predicts Early Recurrence in Head and Neck Cancer
Human papillomavirus (HPV)-associated head and neck cancers are frequently treated with surgery, but some patients experience recurrence due to residual microscopic disease. Postoperative decisions about... Read more
New Library Normalization and Amplification Tools Support Oncology Sequencing
High-throughput next-generation sequencing (NGS) laboratories continue to grapple with uneven library pooling and amplification artifacts that can degrade variant calling accuracy and increase reruns.... Read moreHematology
view channel
Next-Generation Hematology Platform Streamlines High-Complexity Lab Workflows
Sysmex America (Chicago, IL, USA) has introduced the next generation XR-Series, centered on the XR-10 Automated Hematology Module for high-complexity laboratories. The platform builds on the widely used... Read more
Blood Eosinophil Count May Predict Cancer Immunotherapy Response and Toxicity
Immune checkpoint inhibitors have improved outcomes across many cancers, yet only a subset of patients derive durable benefit and biomarkers to guide treatment remain limited. Eosinophils, best known for... Read moreImmunology
view channelAptamer-Based Biosensor Enables Mutation-Resilient SARS-CoV-2 Detection
Rapid evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can undermine existing molecular diagnostics, especially when assays target small viral components. Double-antibody sandwich... Read more
Study Points to Autoimmune Pathway Behind Long COVID Symptoms
Long COVID leaves many SARS-CoV-2 survivors with persistent fatigue, cognitive issues, palpitations, and musculoskeletal pain for months or years. Estimates cited in new research suggest 4%–20% of infected... Read more
Metabolic Biomarker Distinguishes Latent from Active Tuberculosis and Tracks Treatment Response
Tuberculosis (TB) remains the world’s leading infectious killer, with 10.8 million cases and 1.25 million deaths recorded globally in 2023. Yet many infected individuals never develop active disease, underscoring... Read moreMicrobiology
view channel
TORCH Infection Trends Point to Need for Tailored Screening in Pregnancy
Congenital TORCH infections can be asymptomatic during pregnancy yet cause stillbirth, birth defects, and lifelong disability in infants. Many regions still lack robust surveillance to guide testing and... Read more
New Culture Medium Speeds C. difficile Resistance Detection and Reduces Costs
Clostridioides difficile infections remain a persistent threat in hospitals and communities, affecting about 500,000 people in the United States each year. Severe cases can be fatal within 30 days of diagnosis,... Read morePathology
view channel
Uncertainty-Aware AI Platform Supports Automated HER2 Assessment in Breast Cancer
Accurate assessment of human epidermal growth factor receptor 2 (HER2) is critical for breast cancer diagnosis and treatment selection, yet scoring variability and infrastructure requirements can complicate... Read more
AI Tool Speeds Brain Tumor Classification from Routine Histology Slides
Accurate classification of brain and spinal cord tumors increasingly depends on molecular profiling alongside histology, but access to such testing remains limited and results can take about two weeks.... Read more
IHC Companion Diagnostic Standardizes Mismatch Repair Testing for Cancer Immunotherapy
Deficient DNA mismatch repair is an established predictive biomarker for response to immune checkpoint inhibitors, yet access to standardized assessment has varied across tumor types. Cancer remains the... Read moreTechnology
view channel
AI Platform Links Biomarker Results to Cancer Clinical Trials and Guidelines
Oncology teams must manage growing volumes of genomic data, rapidly evolving clinical trial options, and frequently updated care guidelines, all within tight clinic schedules. Translating complex tumor... Read more
Agentic AI Platform Supports Genomic Decision-Making in Oncology
Oncology care teams increasingly face the challenge of managing complex molecular diagnostics, evolving treatment options, and extensive electronic health record documentation. Translating multimodal data... Read moreIndustry
view channel
Open-Source Consortium Aims to Standardize Digital Pathology Workflows
Digital pathology is expanding rapidly as laboratories adopt whole-slide imaging and computational tools to meet growing diagnostic and biomarker-testing demand. However, fragmented software infrastructure... Read more