LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Automated Fluorescent Microbial Cell Counter Detects Urinary Tract Infection

By LabMedica International staff writers
Posted on 15 Jul 2020
Image: The QUANTOM Tx Microbial Cell Counter is an image-based, automated cell counter that can identify and count individual bacterial cells in minutes (Photo courtesy of Logos Biosystems).
Image: The QUANTOM Tx Microbial Cell Counter is an image-based, automated cell counter that can identify and count individual bacterial cells in minutes (Photo courtesy of Logos Biosystems).
Urinary tract infections (UTI) accounted for around 400,000 hospitalizations, resulting in an estimated cost burden of approximately USD 2.8 billion in the USA. Between 50% and 60% of adult women will have at least one UTI in their life, and close to 10% of postmenopausal women indicate that they had a UTI in the previous year.

A rapid urinalysis is usually conducted upon presentation with UTI‐related symptoms in patients. A rapid urinalysis screens the urine for ketones, proteins, reducing substances, red blood cells (RBC), white blood cells (WBC), nitrites, and pH levels outside the normal range (4.5 to 8.0). The most common pathogen associated with UTI globally is Escherichia coli.

Gastroenterologists and their associates at the Sinai Hospital (Baltimore, MD, USA) obtained clean‐catch urine samples from 10 healthy control subjects with a negative urinalysis result and 11 subjects with suspected UTI with a positive urinalysis and culture result for E. coli. Urine samples that received a positive result were plated onto blood agar and MacConkey medium for growth analysis. Urine samples were analyzed using the QUANTOM Tx Microbial Cell Counter (Logos Biosystems, Annandale, VA, USA) upon reception from the microbiology laboratory.

The scientists reported that the mean cellular concentration for the 11 E. coli‐positive samples was 1.01 × 108 cells/mL (range = 2.5 × 107–3.29 × 108 ± SD = 8.9 × 107). The average cellular concentration for the 10 control samples was 2.35 × 106 cells/mL (range = 9.42 × 105–5.93 × 106 ± SD = 1.56 × 106). The difference in cellular concentration between the E. coli‐positive and control groups was found to be statistically significant.

The authors concluded that the automated microbial cell counter represents a significant step toward high throughput, reproducible microbial cell observation, and quantification. A significant difference in cellular concentration was observed between E. coli‐positive UTI samples and controls measured with an automated microbial cell counter. Thus, automated microbial cell counters may serve important roles as preliminary screening tools in clinical diagnostic settings. The study was published on July 4, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Sinai Hospital
Logos Biosystems


Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Silver Member
PCR Plates
Diamond Shell PCR Plates
HBV DNA Test
GENERIC HBV VIRAL LOAD VER 2.0

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more