Elevated Metal Ion Level Detects Defective Hip Arthroplasty Implants

By LabMedica International staff writers
Posted on 26 May 2020
Print article
Image: The Element 2 High Resolution, Sector-Field, Inductively Coupled Plasma Mass Spectrophotometer (HR-ICP-MS) (Photo courtesy of Thermo Fisher Scientific).
Image: The Element 2 High Resolution, Sector-Field, Inductively Coupled Plasma Mass Spectrophotometer (HR-ICP-MS) (Photo courtesy of Thermo Fisher Scientific).
Total hip replacement (THR) has proven to be a highly effective treatment of degenerative joint disease. Hip replacement implants can be made of different metallic alloys according to their specific properties and the related clinical need.

Metal ions from these alloys will be systematically released due to the bearing wear, taper junction wear/corrosion or passive surface corrosion. Performance of each implant can be assessed indirectly by measuring systemic ion levels in whole blood.

Medical Laboratory Scientists at the Maisonneuve-Rosemont Hospital (Montreal, QC, Canada) collected 71 whole blood samples were collected from 64 patients with unilateral ceramic-on-ceramic hip arthroplasty. For each patient, two whole blood samples were collected and analyzed in two different laboratories.

The investigators analyzed 71 pairs of whole blood samples from 64 patients. Patient’s mean age at time of surgery was 54 years old (range 33–73; ± 9.2), 26 men and 38 women. In one laboratory the concentrations of titanium (Ti), Chromium-cobalt (Cr and Co) ions in whole blood samples were measured with a single quadrupole ICP-MS Elan DRCII (PerkinElmer, Waltham, MA, USA). The detection limits were 0.1 μg/L for Cr and 0.035 μg/L for Co. In the other laboratory the concentrations of Ti, Cr and Co ions in the whole blood samples were measured in an Element 2 High Resolution, Sector-Field, Inductively Coupled Plasma Mass Spectrophotometer (HR-ICP-MS, Thermo Fisher Scientific GmBH, Bremen, Germany). The detection limits were 0.1 μg/L for Cr and 0.02 μg/L for Co.

The scientists reported that the for distributions of Ti concentrations from the two laboratories there was no distinction for the direction of the difference in Ti concentration (minus or positive) since 100% of results from laboratory 1 were higher than laboratory 2. The concentrations obtained from laboratory 1 are significantly different from those of laboratory 2. The average ratio between laboratories (#1 divided by #2) is 4.10 (range 1–20.76). In 69% of cases the difference was above 300%, and in 39% above 500%. The team found that 64/71 (90%) of paired samples had an absolute difference above the predetermined threshold of 1 μg/L. A mean variation ratio of 410% between the two laboratories was found.

The authors concluded that metal ions blood screening is a common way of detecting mal-functioning orthopedic implants. However, all laboratories do not use the same technologies or calibrations to do these measurements. Different laboratories leading to a significant risk of misinterpretation can measure clinically significant level difference. Therefore, clinical decision should not rely on a single measurement made by one laboratory. The study was published on May 8, 2020 in the journal Practical Laboratory Medicine.

Gold Member
Flocked Fiber Swabs
Puritan® Patented HydraFlock®
Verification Panels for Assay Development & QC
Seroconversion Panels
New
H.pylori Test
Humasis H.pylori Card
New
Dermatophytosis Rapid Diagnostic Kit
StrongStep Dermatophytosis Diagnostic Kit

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Sekisui Diagnostics UK Ltd.