LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Sweat Chloride Quantified Using Capillary Electrophoresis

By LabMedica International staff writers
Posted on 18 Feb 2019
Image: The Wyn-CE Adaptive Capillary Electrophoresis system and ER815 C4D Detector (Photo courtesy of WynSep).
Image: The Wyn-CE Adaptive Capillary Electrophoresis system and ER815 C4D Detector (Photo courtesy of WynSep).
Cystic fibrosis (CF) is the less rare and severe genetic disease among the European population. Biochemical diagnosis of CF is based on the demonstration of increased chloride concentration in sweat samples, obtained during the sweat test (ST).

Capillary electrophoresis (CE) is able to directly measure chloride. CE is already known as a high performance separation technique, quick and a low-sample volume consumer/user, for and with different matrixes. This method has been shown as a useful tool for analysis of sweat chloride.

Scientists at the Hôpital Purpan (Toulouse, France) and their colleagues carried out a study on subjects referred to our laboratory for a ST between May and August 2017. During this period, a total of 65 sweat samples were processed for the diagnosis or for the initiation or follow-up of a new treatment. The mean age of all 48 subjects was 9.8 ± 10.7 years; median 5 (ranging from 0.1 to 58) years. The sweat induction was carried out by pilocarpine iontophoresis, the gold standard, with Webster Sweat Inducer. Then sweat was collected during 25 minutes with Macroduct collector.

The team used the ELITech Wescor ChloroChek Chloridometer test system, model 3400, to measure the chloride in human sweat using the principle of coulometric titration. This assay required at least 10 µL of sweat and provided a digital readout in mmol/L. A comparison test was performed with a capillary electrophoresis with contactless conductivity detection system (CE-C4D). This assay required only 2 µL.

The investigators reported that the concentration of sweat chloride, determined by coulometry, allowed them to distinguish three groups of patients, according to the new consensus guideline: (i) control group of 44 with chloride less than 30 mmol/L; three subjects as borderline group with chloride between 30 and 59 mmol/L; and a CF group of 18 with chloride equal to or greater than 60 mmol/L. The method validation showed comparable analytical performances for both methods; no false positive or false negative was recorded. The two methods showed a high correlation and a close agreement was demonstrated by two different statistical tests.

The authors concluded that WynSep CE is an accurate, fast, easy-to-use method and an appropriate technique for CF diagnosis. The WynSep CE device also offers a strong financial advantage, and as it is not dedicated to only sweat chloride assay and can be used for measurement of a variety of analytes. The study was published in the January 2019 issue of the journal Practical Laboratory Medicine.

Related Links:
Hôpital Purpan


Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Human Estradiol Assay
Human Estradiol CLIA Kit
6 Part Hematology Analyzer with RET + IPF
Mispa HX 88

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more