POC Testing Compared to Automated Blood Glucose Analysis

By LabMedica International staff writers
Posted on 13 Sep 2016
Image: The OneTouch UltraVue POC blood glucose monitor (Photo courtesy of Johnson & Johnson).
Image: The OneTouch UltraVue POC blood glucose monitor (Photo courtesy of Johnson & Johnson).
Diabetes mellitus is a metabolic disease that is characterized by hyperglycemia and blood glucose (BG) levels are helpful for the diagnosis and treatment of diabetes and an important part of the management of diabetes.

Point-of-care testing (POCT) is generally used by patients themselves or medical personnel to monitor BG. As it is simple to use and supplies rapid results, it might accelerate clinical decision-making and improve patients' prognosis.

Scientists at the Guangxi Medical University (Nanning, China) carried out a retrospective study comprising 162 volunteers (97 males and 65 females; median age, 47 years; range, 14 to 67 years). Blood samples were collected with anticoagulation tubes for which hematocrit values ranged between 34.5% and 54% and the range of glucose concentrations were 1.60–21.30 mmol/L. Each sample was divided into two parts; one was separated by centrifugation and measured by the central laboratory system, and the other was measured by the POCT system in whole blood.

The team tested three types of BG meter: They were the ACCU-CHEK Performa and the ACCU-CHEK Active (Roche Diagnostics, Basel, Switzerland), and the OneTouch UltraVue (Johnson & Johnson Medical Ltd, Shanghai, China). The clinical laboratory measurement system used the Glucose GOD-PAP method with a Hitachi 7600-120 analyzer (Hitachi Corporation, Tokyo, Japan) as a reference system.

The investigators showed that BG concentrations measured by venous whole blood was comparable with the reference method. Although the POCT can provide rapid measurement results, the type of specimen, interference factors, environmental conditions, and hematocrit may affect the results. The measurement accuracy of the POCT systems, being 94.9%, 92.6%, and 96.7% for ACCU-CHEK Performa, ACCU-CHEK Active, and OneTouch UltraVue, respectively, did not all meet the requirements. The same result was found for BG concentrations equal to or greater than 5.55 mmol/L (100 mg/dL). With BG concentrations of less than 5.55 mmol/l (100 mg/dL), the accuracy of all POCT systems meet the criteria.

The authors concluded that their study indicated that the POCT system could only be used as a screening test for continuous, qualitative, or semi-quantitative detection as a complement emergency measure to the central laboratory, instead of being used as a standard result in clinical diagnosis. If the POCT system is used in testing too low or too high BG concentrations in clinical diagnosis, it may mislead the diagnosis and treatment. The study was published on August 25, 2016, in the Journal of Clinical Laboratory Analysis.

Related Links:
Guangxi Medical University
Roche Diagnostics
Johnson & Johnson Medical
Hitachi Corporation
Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gold Member
Hematology Analyzer
Medonic M32B
Gel Cards
DG Gel Cards

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more