Blood Spots Compared with Plasma Sample for Chitotriosidase Assay

By LabMedica International staff writers
Posted on 07 Jan 2014
Image: FP-6200 Series Spectrofluorometer (Photo courtesy of Jasco).
Image: FP-6200 Series Spectrofluorometer (Photo courtesy of Jasco).
The chitotriosidase enzyme is markedly elevated in plasma of patients with Gaucher's disease, a relatively common lysosomal storage disorder (LSD).

Chitotriosidase activity in plasma is also established as a therapeutic monitor for enzyme replacement therapy in Gaucher's patients and is under consideration to monitor therapy in other diseases such as Fabry disease, nephropathic cystinosis, and sarcoidosis.

Clinical biochemists at Cairo University (Giza, Egypt) compared blood spot samples with the corresponding plasma levels in 199 children of whom 56 were with confirmed diagnoses of 10 different lysosomal storage disorders, 73 normal controls, and 70 pathological controls. Several performance criteria such as limit of detection, linearity, within-run and day-to-day precision and sample stability were also evaluated.

Chitotriosidase activity in plasma and blood spot samples was measured using the substrate 4-methylumbelliferyl-β-D-N,N′,N″-triacetylchitotrioside (4-MU-C3) (Sigma-Aldrich; St. Louis, MO, USA). Fluorescence activity was measured with a FP 6200 spectrofluorometer, (Jasco; Tokyo, Japan) with excitation at 365 nm, and emission at 448 nm. Enzyme activities were calculated based on a calibration curve of 4-methylumbelliferone (4-MU) for each assay.

The calculated values for limit of detection were very comparable between the two methods: 2.7 and 2.0 nmol/mL/h for the plasma and blood spot assays, respectively. Similarly, the determined limits of quantification were 3.6 nmol/mL/h for plasma and 3.5 nmol/mL/h for blood spots. Although the precision using blood spots was inferior to plasma, it was quite acceptable for a blood spot method as the calculated limit of detection for blood spots was acceptable, looking at the wide range of the analytical spectrum. The plasma cutoff limit of 1,000 nmol/mL/h offered 100% sensitivity and 99% specificity for Gaucher's patients, while a blood spot cutoff limit of 400 nmol/mL/h offered 100% sensitivity and 97% specificity.

The authors concluded that blood spot sampling offers many advantages over traditional venous sampling. The level of agreement between blood spot and plasma chitotriosidase using the 4-MU-C3 substrate was found to be acceptable. Blood spot chitotriosidase is a clinically valid test. The study was published in the January 2014 issue of the journal Clinical Biochemistry.

Related Links:

Cairo University
Sigma-Aldrich
Jasco


Gold Member
Immunochromatographic Assay
CRYPTO Cassette
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Rapid Molecular Testing Device
FlashDetect Flash10
Automatic Hematology Analyzer
DH-800 Series

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more