We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Point-of-Care Device Compared for Cardiac Troponin Assay

By LabMedica International staff writers
Posted on 02 Oct 2013
Print article
Image: The i-STAT portable clinical analyzer system (Photo courtesy of Abbot Laboratories).
Image: The i-STAT portable clinical analyzer system (Photo courtesy of Abbot Laboratories).
A fingerstick point-of-care (POC) testing for cardiac troponin I has been compared to conventional venipuncture POC testing.

Cardiac troponin assays commonly exceed one hour while point-of-care testing can be completed in minutes by basic life support personnel so when patients present complaining of chest pain, time can be critical to achieving positive outcomes.

Scientists at the Loyola University Medical Center (Maywood, IL, USA) collected fingerstick blood samples from consenting patients for whom standard-of-care venipuncture POC troponin (POCT) testing had been ordered as part of their workup. Cardiac troponin (cTnl) assays were performed using a commercial device from June to August 2011. Eighty-nine cTnI levels were measured by both fingerstick and standard venipuncture emergency department POC testing. Four resulted in cartridge error so only the remaining 85 were analyzed.

Cardiac troponin I (cTnI) assays were performed using an i-STAT 1 device (Abbott Point of Care; Princeton, NJ, USA). Fingerstick testing, compared with standard ED POCT, has a positive predictive value of 1.00 (0.48, 1.00), a negative predictive value of 0.96 (0.89, 0.99), a sensitivity of 0.625 (0.24, 0.91), and a specificity of 1.00 (0.95, 1.00). The relationship between methods appeared to be linear.

The authors concluded that fingerstick cTnI testing using the i-STAT device is not accurate enough to determine the exact troponin level without the application of a corrective term. Fingerstick testing is, however, accurate in qualifying troponin levels as negative, borderline, or positive and is, therefore, capable of providing clinical information that may guide diagnostic and therapeutic decision-making. The study was published in the August 2013 issue of the American Journal of Emergency Medicine.

Related Links:
Loyola University Medical Center
Abbott Point of Care


Gold Member
Flocked Fiber Swabs
Puritan® Patented HydraFlock®
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Lyme Disease Test
Lyme IgG/IgM Rapid Test Cassette
New
Myeloperoxidase Assay
IDK MPO ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Sekisui Diagnostics UK Ltd.