Autosomal Dominant Disorder Confirmed by Biomarker Assay

By LabMedica International staff writers
Posted on 06 Feb 2012
The erythrocyte glucose-uptake assay has been used to confirm the diagnosis of glucose transporter type 1 deficiency syndrome (Glut1-DS).

The disease is diagnosed with cerebrospinal fluid (CSF) glucose values of less than 2.2 mmol/L, or lowered CSF/plasma glucose ratio of less than 0.4, and the erythrocyte 3-O-methyl-d-glucose uptake assay (3-OMG).

Scientists at Columbia University (New York, NY, USA) studied 109 suspected cases of Glut-1 DS, all who had a consistent clinical picture and a low CSF glucose concentration (hypoglycorrhachia). To confirm the diagnosis of Glut1 DS, blood samples from both patients and parents were analyzed using the erythrocyte 3-OMG uptake assay. The erythrocytes are radioactively labeled and measured on a scintillation counter.

Copy number analysis was performed via single nucleotide polymorphism (SNP) oligonucleotide microarray analysis (SOMA) using the Affymetrix Genome Wide Human SNP Array 6.0 (Santa Clara, CA, USA), which includes over 906,600 SNPs and more than 946,000 probes for the detection of copy number variation. A multiplex ligation-dependent probe amplification (MLPA) kit (MRC-Holland; Amsterdam, Netherlands) was used to screen eight patients with decreased 3-OMG uptake without identified sequence based mutations or deletions using SOMA. .

The uptake assay was decreased in 74 cases (group 1) and normal in 35 cases (group 2). The disease-causing mutations were identified in 70 group 1 patients (95%) and only one in group 2 patients (3%). The cut-off for an abnormally low uptake value was increased from 60% to 74% with a corresponding sensitivity of 99% and specificity of 100%. The correlation between the uptake values for the time-curve and the kinetic concentration curve were strongly positive. There was a significant correlation between the mean erythrocyte 3-OMG uptake and clinical severity.

The authors concluded that the erythrocyte glucose-uptake assay, when abnormal, essentially confirms the clinical suspicion of Glut1 DS. Furthermore, the degree of uptake abnormality correlates with glucose transport functional activity and has implications regarding clinical severity and prognosis. Glut1 deficiency syndrome is characterized classically by infantile onset seizures, delayed neurological development, disorders of movement, and acquired microcephaly. The study was published in December 2011, in the Annals of Neurology.

Related Links:

Columbia University
Affymetrix
MRC-Holland


Gold Member
Fibrinolysis Assay
HemosIL Fibrinolysis Assay Panel
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit
Hemodynamic System Monitor
OptoMonitor

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more