LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Primary Screening Test for Diabetes Reevaluated

By LabMedica International staff writers
Posted on 04 Jan 2012
The blood test for glycosalated hemoglobin, Hb1Ac, has been recently recommended as the primary diagnostic test for diabetes.

The HbA1c blood test is the accepted standard for monitoring long-term glycemic control in patients with diabetes, however until recently, HbA1c was not recommended for diagnosing or screening for diabetes.

In a retrospective study carried out by DynaLIFEDx, Edmonton, AB, Canada) in conjunction with local medical practitioners, evaluated the positive predictive value (PPV) and negative predictive value (NPV) of HbA1c against the oral glucose tolerance test (OGTT) values using a 10% prevalence of diabetes in three locations. DynaLIFEDx is a major Canadian medical laboratory offering a complete range of diagnostic testing services. For a three-year period, 3,163 data pairs were collected including 1,537 males and 1,626 females with a mean age of 55.4 ± 14.7 years. The OGTT criteria for diabetes were found for 568 out of the 3,163 sets.

Blood glucose was measured on the ARCHITECT ci8200 (Abbott Laboratories; Mississauga, ON, Canada) using a hexokinase method and HbA1c was measured by high performance liquid chromatography (HPLC) on a VARIANT II analyzer (Bio-Rad laboratories, Montreal, QC, Canada). The recommended threshold HbA1c value of 6.5% did not give the optimal combination of NPV of 0.93 to 0.92 and PPV of 0.40 to 0.61 compared to a threshold HbA1c value of 7.0% that gave an NPV of 0.91 to 0.92, and PPV of 0.61 to 0.73.

The authors concluded that HbA1c is not satisfactory for use as a diagnostic test for diabetes using the threshold values recommended by the Consensus Committee and the International Expert panel due to low positive predictive values. About 12% of individuals with a normal OGTT test will be diagnosed with diabetes using a threshold HbA1c value of 7.0%. This would put considerable burden on health care resources. However, based on the high negative predictive value, HbA1c may be used as a test to rule-out diabetes. The study was published in the December 2011 issue of the journal Clinical Biochemistry.

Related Links:

DynaLIFEDx
Abbott Laboratories
Bio-Rad


Gold Member
Respiratory Syncytial Virus Test
OSOM® RSV Test
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Autoimmune Liver Diseases Assay
Microblot-Array Liver Profile Kit
Capillary Blood Collection Tube
IMPROMINI M3

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more