Blood Gases Analyses Reevaluated for Cord Blood

By LabMedica International staff writers
Posted on 25 Oct 2010
Cord blood arterial and venous reference ranges for acidity or alkalinity (pH), partial pressure of oxygen (pO2), and partial pressure of carbon dioxide (pCO2) in newborns has been reevaluated.

The blood gases and pH were measured in the cord blood of newborns, who were delivered either by spontaneous vaginal delivery (SVD) or by cesarean section (CS).

Cord blood samples were analyzed for standard blood gas and pH, using the analytical device Rapid Lab 845 and Rapid Lab 865 (Siemens Medical Diagnostics; Bayer, Tarrytown, NY, USA).

In a study carried out at the Charles University (Prague, Czech Republic), two groups of newborns, group I consisted of 303 delivered with SVD and group II consisted of 189 infants delivered by cesarean section.

The results of cord blood from SVD newborns: arterial cord blood: pH = 7.01-7.39; pCO2 = 4.12 kPa - 11.45 kPa; pO2 = 1.49 kPa - 5.06 kPa; venous cord blood: pH = 7.06-7.44; pCO2 = 3.33 kPa - 9.85 kPa; pO2=1.80 kPa - 6.29 kPa. Reference values for cord blood in newborns delivered by CS were: arterial cord blood: pH = 7.05-7.39; pCO2 = 5.01 kPa - 10.60 kPa; pO2 = 1.17 kPa - 5.94 kPa; venous cord blood: pH =7.10–7.42; pCO2 = 3.88 kPa - 9.36 kPa; pO2 = 1.98 kPa - 7.23 kPa.

The authors stated that pH values lower than 7.0 are considered with high-risk incidence of complications. The association between umbilical arterial acidosis and adverse neurological events in infants is characterized with arterial pH <7.20. Neonatal death was much more likely when the pH <7.05 and when unexplained events became more likely, the pH was <7.00. It was recommended that the value for defining pathological acidemia is pH <7.00. It was found that hypoxic–ischemic encephalopathy occurred in 12% of infants with pH <7.00, 33 % with pH <6.9, 60% with pH <6.8, and 80 % with pH <6.7.

In mothers ventilated with 100% O2 during CS, the upper 95% confidence level for umbilical arterial pO2 was 4.9 kPa. These data indicated that cord arterial samples with pO2 greater than 5.0 kPa are likely to have been affected by the presence of an air bubble contamination in the specimen. Because CO2 content of air is very low, this can be accompanied by lowering the pCO2 followed by a large rise in pH, with consequent risk of misinterpretation. Maternal hyperventilation lowers fetal pO2.

The study was published on September 20, 2010 in the Journal of Clinical Laboratory Analysis.

Related Links:

Siemens Medical Diagnostics
Charles University




Gold Member
Immunochromatographic Assay
CRYPTO Cassette
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Pipette
Accumax Smart Series
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more