Simple Colorimetric Assay Determines Human Mercaptalbumin Concentration
By LabMedica International staff writers Posted on 30 Jun 2022 |

Image: VICTOR Nivo Multimode Microplate Reader (Photo courtesy of PerkinElmer)
Human serum albumin (HAS) can take on two forms, mercaptalbumin (HMA) or non-mercaptalbumin (HNA), depending on the redox status of its Cys34. The ratio of HMA and HNA is considered to be a novel biomarker of oxidative stress.
The majority of studies on the redox state of HSA utilize high performance liquid chromatography (HPLC). Several recent studies have also employed mass spectrometry, which yields a higher resolution, thus allowing for finer distinctions between molecular structures. A handful of studies have explored alternative approaches using simple dye-based assays.Clinical Laboratorians at The University of Tokyo Hospital (Tokyo, Japan) collaborated with colleagues at Nitto Boseki Co. Ltd., (Kawasaki, Japan) measured the concentrations of HMA in serum samples from 36 healthy subjects based on absorption changes of Michler's Hydrol. Michler's Hydrol (4,4′-Bis(dimethylamino)benzhydrol) is a blue dye with a maximum absorption at 612 nm, and its absorption decreases when it reacts with a thiol group.
After processing the samples, the solution was incubated further at room temperature for 20 minutes and absorbance at 612 nm (A612) was measured by a 96-well plate Nivo 3F microplate reader (PerkinElmer, Waltham, MA, USA). To evaluate the performance of the assays, the correlation was determined by a linear regression between the HMA concentrations obtained by Michler's Hydrol assay and corresponding reference concentrations obtained by HPLC and Bromocresol purple (BCP) assays.
The scientists reported that HMA concentrations obtained by Michler's Hydrol assay were highly correlated (r2 = 0.97) with reference values obtained by HPLC (HMA %) and BCP assay (total albumin). The HNA% obtained by Michler's Hydrol and BCP assays combined also gave a good correlation (r2 = 0.96) and a small deviation (average 2.4%) with respect to HPLC as a reference method. The use of the HMA/HNA ratio, which is a function of oxidation of Cys34, is considered a potential biomarker to assess the severity of chronic diseases for which oxidative stress is a significant etiological manifestation.
The authors concluded that the concentrations of HMA in human serum can be measured by Michler's Hydrol assay, which is based on an approximation of HMA concentrations with Michler's Hydrol's colorimetric changes mainly due to thiols. The assay accuracy was significantly improved by pre-incubation of a subset of the samples with an alkylating agent (iodoacetamide) and subtracting their absorption from the absorption of corresponding samples without alkylation. Proportions of HMA and HNA were also obtained by combining Michler's Hydrol assay and the BCP assay (for total albumin concentration). The results correlated well with HPLC, which has been established as a standard method for HMA/HNA measurement. The study was published on June 8, 2022 in the journal Practical Laboratory Medicine.
Related Links:
The University of Tokyo Hospital
Nitto Boseki Co. Ltd
PerkinElmer
Latest Technology News
- Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
- Innovative, Label-Free Ratiometric Fluorosensor Enables More Sensitive Viral RNA Detection
- Smartphones Could Diagnose Diseases Using Infrared Scans
- Novel Sensor Technology to Enable Early Diagnoses of Metabolic and Cardiovascular Disorders
- 3D Printing Breakthrough Enables Large Scale Development of Tiny Microfluidic Devices
- POC Paper-Based Sensor Platform to Transform Cardiac Diagnostics
- Study Explores Impact of POC Testing on Future of Diagnostics
- Low-Cost, Fast Response Sensor Enables Early and Accurate Detection of Lung Cancer
- Nanotechnology For Cervical Cancer Diagnosis Could Replace Invasive Pap Smears
- Lab-On-Chip Platform to Expedite Cancer Diagnoses
- Biosensing Platform Simultaneously Detects Vitamin C and SARS-CoV-2
- New Lens Method Analyzes Tears for Early Disease Detection
- FET-Based Sensors Pave Way for Portable Diagnostic Devices Capable of Detecting Multiple Diseases
- Paper-Based Biosensor System to Detect Glucose Using Sweat Could Revolutionize Diabetes Management
- First AI-Powered Blood Test Identifies Patients in Earliest Stage of Breast Cancer
- Optical Biosensor Rapidly Detects Monkeypox Virus at Point of Care
Channels
Clinical Chemistry
view channel
Carbon Nanotubes Help Build Highly Accurate Sensors for Continuous Health Monitoring
Current sensors can measure various health indicators, such as blood glucose levels, in the body. However, there is a need to develop more accurate and sensitive sensor materials that can detect lower... Read more
Paper-Based Device Boosts HIV Test Accuracy from Dried Blood Samples
In regions where access to clinics for routine blood tests presents financial and logistical obstacles, HIV patients are increasingly able to collect and send a drop of blood using paper-based devices... Read moreMolecular Diagnostics
view channel
RNA-Based Blood Test Detects Preeclampsia Risk Months Before Symptoms
Preeclampsia remains a major cause of maternal morbidity and mortality, as well as preterm births. Despite current guidelines that aim to identify pregnant women at increased risk of preeclampsia using... Read more
First Of Its Kind Test Uses microRNAs to Predict Toxicity from Cancer Therapy
Many men with early-stage prostate cancer receive stereotactic body radiotherapy (SBRT), a highly precise form of radiation treatment that is completed in just five sessions. Compared to traditional radiation,... Read more
Novel Cell-Based Assay Provides Sensitive and Specific Autoantibody Detection in Demyelination
Anti-myelin-associated glycoprotein (MAG) antibodies serve as markers for an autoimmune demyelinating disorder that affects the peripheral nervous system, leading to sensory impairment. Anti-MAG-IgM antibodies... Read moreHematology
view channel
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read more
Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
In the United States, approximately 15% of pregnant individuals are RhD-negative. However, in about 40% of these cases, the fetus is also RhD-negative, making the administration of RhoGAM unnecessary.... Read moreImmunology
view channel
Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more
Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
Chimeric antigen receptor (CAR) T-cell therapy has emerged as one of the most promising recent developments in the treatment of blood cancers. However, over half of non-Hodgkin lymphoma (NHL) patients... Read moreMicrobiology
view channel
Handheld Device Deliver Low-Cost TB Results in Less Than One Hour
Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more
New AI-Based Method Improves Diagnosis of Drug-Resistant Infections
Drug-resistant infections, particularly those caused by deadly bacteria like tuberculosis and staphylococcus, are rapidly emerging as a global health emergency. These infections are more difficult to treat,... Read more
Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours
Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read morePathology
view channel
Advanced Imaging Reveals Mechanisms Causing Autoimmune Disease
Myasthenia gravis, an autoimmune disease, leads to muscle weakness that can affect a range of muscles, including those needed for basic actions like blinking, smiling, or moving. Researchers have long... Read more
AI Model Effectively Predicts Patient Outcomes in Common Lung Cancer Type
Lung adenocarcinoma, the most common form of non-small cell lung cancer (NSCLC), typically adopts one of six distinct growth patterns, often combining multiple patterns within a single tumor.... Read moreIndustry
view channel
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more