LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Capillary and Venous Blood Sampling Compared for Coagulation Assays

By LabMedica International staff writers
Posted on 17 Mar 2022
Image: The ACL-TOP 750 LAS coagulation analyzer (Photo courtesy of Werfen)
Image: The ACL-TOP 750 LAS coagulation analyzer (Photo courtesy of Werfen)

Clinical laboratories offer a wide range of coagulation assays used in the diagnosis and management of patients with hemostatic disorders, preoperative screening, or anticoagulation therapy monitoring.

The request from clinicians for capillary blood collection for other routine coagulation test, such as International Normalized Ratio, prothrombin time, activated partial thromboplastin time, and thrombin time, remains significant in particular from those involved in pediatrics. Capillary sampling offers a less invasive method for blood collection than venipuncture, which makes it more suitable for neonates, young children as well as for adult patients with poor venous access or severe anxieties concerning blood sampling.

Diagnostic Laboratorians at the University Medical Center Utrecht (Utrecht, The Netherlands) performed a method comparison between capillary and venous blood sampling for routine coagulation assays. Both venous and capillary (finger stick) blood samples were collected from 188 healthy volunteers and patients. In citrate plasma, International Normalized Ratio (INR), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen, and D-dimer were measured according to routine protocols using the ACL-TOP 750 LAS (Werfen, Bedford, MA, USA) coagulation analyzer. Regression analysis was performed and the mean relative difference between capillary and venous sampling was reflected to the total allowable error.

The scientists reported that there was a strong correlations and acceptable variations, using the total allowable error (TEa) as decision limit, were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling, However, capillary sampling resulted in significant shorter APTT values when using the standard APTT-SP Liquid reagent with a mean bias of −10.4%.. The mean relative difference of TT and fibrinogen was −1.7% and −3.7%, respectively, but were considered acceptable variations using the TEa as a decision limit. D-dimer showed a mean relative difference of 1.2%], which fell within the range of acceptable variation.

The authors concluded that strong correlations and acceptable variations were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling. However, capillary sampling resulted in significantly shorter APTT values when using the standard APTT-SP Liquid reagent. Based on these results, capillary blood sampling proved to be an alternative blood withdrawal method for routine coagulation assays, with the exception of APTT, if a venipuncture is unavailable. The study was originally published online on February 3, 2022, in the journal Clinical Biochemistry.

Related Links:
University Medical Center Utrecht 
Werfen 

Gold Member
Blood Gas Analyzer
Stat Profile pHOx
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gold Member
Hematology Analyzer
Medonic M32B
Capillary Blood Collection Tube
IMPROMINI M3

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more