LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Different Assay Evaluated for Thyroglobulin and Thyroglobulin Antibodies

By LabMedica International staff writers
Posted on 07 Mar 2022
Image: B•R•A•H•M•S KRYPTOR compact PLUS bench top analyzer is designed for small size routine laboratories with a need of up to eight different immunoassays and a throughput of up to approximately 60 test per hour. (Photo courtesy of Multi Sarana Medika)
Image: B•R•A•H•M•S KRYPTOR compact PLUS bench top analyzer is designed for small size routine laboratories with a need of up to eight different immunoassays and a throughput of up to approximately 60 test per hour. (Photo courtesy of Multi Sarana Medika)

Measurement of serum thyroglobulin (Tg) has an essential role in follow-up monitoring of patients with differentiated thyroid cancer (DTC). Tg measurements in combination with a neck ultrasound have a high sensitivity for detecting persistent or recurrent disease in patients previously treated with thyroidectomy and radioactive iodine (RAI) ablation.

Currently, most laboratories have adopted an automated immunometric assay for measurement of Tg. In recent years the diagnostic sensitivity has been improved with the introduction of assays with functional sensitivities (FS) ≤0.1 μg/L, also referred to as high-sensitive Tg assays (hs-Tg). The measurement of Tg is complicated by multiple factors.

Internal Medicine Specialists at the Erasmus Medical Center (Rotterdam, The Netherlands) and their colleagues aimed to evaluate if different assays for Tg and Tg antibodies (TgAb) affect management guidance for differentiated thyroid cancer (DTC) patients. In 793 samples derived from 413 patients with DTC, Tg and TgAb were simultaneously measured with two immunometric assays.

Serum Tg was measured with two immunometric assays: Immulite 2000XPi (Siemens Healthcare Diagnostics Inc, Tarrytown, NY, USA) and Kryptor compact plus (B.R.A.H.M.S Thermo Fischer Scientific, Hennigsdorf, Germany). In addition, a qualitative measurement for TgAb interference (recovery test) was performed on the Kryptor compact plus platform. The extent to which different assays lead to different classifications of response to therapy was evaluated when applying the current cut-offs for Tg.

The scientists reported that the mean Tg concentrations were 37.4% lower with Kryptor (mean 39.5 μg/L) as compared with Immulite (mean 63.1 μg/L). Applying guideline based cut-off values for Tg, 33 (4.7%) samples had a Tg-on concentration ≥1.0 μg/L with Immulite and <1.0 μg/L with Kryptor. Of the samples tested as TgAb+ with at least one assay (n=125), 68 (54.4%) samples showed discrepancy in TgAb status. Differences between Immulite and Kryptor measurements resulted in a change in the response to therapy classification in 94 (12.0%) measurements derived from 67 (16.2%) individual patients.

The authors concluded that a substantial portion of DTC patients were classified differently dependent on which Tg and TgAb assays were used, when applying the cut-off values as defined in clinical guidelines. Such differences can significantly affect clinical management. In the context of large between-method variation, the recommended Tg cut-offs in guidelines should be used with wisdom rather than as fixed cut-offs. The study was originally published online on January 28, 2022 in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Erasmus Medical Center 
Siemens Healthcare Diagnostics
Thermo Fisher Scientific

Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Automatic CLIA Analyzer
Shine i9000
Gold Member
Immunochromatographic Assay
CRYPTO Cassette

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more