LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Pathogenic Antibodies Decline Over Time in VITT

By LabMedica International staff writers
Posted on 25 Sep 2021
Print article
Vaccine-induced immune thrombotic thrombocytopenia (VITT) has been described after vaccination with the adenoviral vector vaccines and can be confirmed by anti–PF4–heparin IgG enzyme-linked immunosorbent assay (Photo courtesy of Arne Müseler)
Vaccine-induced immune thrombotic thrombocytopenia (VITT) has been described after vaccination with the adenoviral vector vaccines and can be confirmed by anti–PF4–heparin IgG enzyme-linked immunosorbent assay (Photo courtesy of Arne Müseler)
Vaccine-induced immune thrombotic thrombocytopenia (VITT) has been described after vaccination with the adenoviral vector vaccines. A syndrome characterized by venous or arterial thrombosis, particularly at unusual sites including cerebral sinus venous thrombosis (CSVT)/splanchnic thrombosis, and mild to severe thrombocytopenia.

VITT is caused by platelet-activating anti–platelet factor 4 (PF4) IgG antibodies, the presence of which can be confirmed by anti–PF4–heparin IgG enzyme-linked immunosorbent assay (ELISA) in combination with PF4-enhanced washed-platelet–activation assays. Clinical and in vitro characteristics of acute VITT closely resemble (autoimmune) heparin-induced thrombocytopenia.

Medical Scientists at the Universitätsmedizin Greifswald (Greifswald, Germany) conducted a study involving 35 patients with serologically confirmed VITT (27 women and eight men; median age, 53 years [range, 18 to 77 years]). The patients’ clinical symptoms started between days five and 18 after vaccination. All the patients presented with thrombocytopenia, and 30 presented with thrombosis.

Anti-PF4 IgG antibodies were tested by PF4/heparin ELISA. The cut-off of the ELISA was defined as optical density (OD) 0.5; samples testing >0.5 - 1.0 were defined as positive, between >1.0 - 2.0 as strongly–positive; greater 2.0 OD were defined as very strongly positive. Platelet activation by the antibodies was tested in a PF4-dependent washed platelet assay. Negatively tested sera were repeated with a new panel of washed platelets on a different day. A positive result was defined as PF4-dependent activation of platelets (lag time, <30 min) of at least two of three different donors.

The scientists reported that results of the PF4-dependent platelet-activation assay became negative in 23 of 35 patients (66%). In 14 of the 15 patients (93%), with follow-up of more than 12 weeks the platelet-activation assay became negative within a median of 12 weeks. In addition, the median optical density on anti–PF4–heparin IgG ELISA declined by 53% between the first and last available blood samples (median optical density, 2.98 versus 1.39). However, full seroreversion to a negative ELISA result (i.e., an optical density of <0.5) was seen in only three patients. In one patient, PF4-dependent platelet-activating antibodies and ELISA optical density values of greater than 3.0 persisted for more than 12 weeks in association with recurrent episodes of thrombocytopenia.

The authors reported that to achieve full protection against coronavirus disease 2019 (Covid-19), a second vaccination is needed after a first dose of ChAdOx1 nCoV-19. On the basis of their small series of patients, subsequent vaccination with an mRNA vaccine appears to be safe after results of platelet-activation assays for VITT antibodies have become negative. When no platelet-activation assay is available, a substantial decline in the optical density on anti–PF4–heparin IgG ELISA may be used as a decision criterion. The study was published on September 8, 2021 in The New England Journal of Medicine.

Related Links:

Universitätsmedizin Greifswald

Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Immunofluorescence Analyzer
MPQuanti
New
Vaginitis Test
Allplex Vaginitis Screening Assay

Print article

Channels

Molecular Diagnostics

view channel
Image: The Mirvie RNA platform predicts pregnancy complications months before they occur using a simple blood test (Photo courtesy of Mirvie)

RNA-Based Blood Test Detects Preeclampsia Risk Months Before Symptoms

Preeclampsia remains a major cause of maternal morbidity and mortality, as well as preterm births. Despite current guidelines that aim to identify pregnant women at increased risk of preeclampsia using... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Deliver Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: Schematic illustration of the chip (Photo courtesy of Biosensors and Bioelectronics, DOI: https://doi.org/10.1016/j.bios.2025.117401)

Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples

Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.