LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Pathogenic Antibodies Decline Over Time in VITT

By LabMedica International staff writers
Posted on 25 Sep 2021
Vaccine-induced immune thrombotic thrombocytopenia (VITT) has been described after vaccination with the adenoviral vector vaccines and can be confirmed by anti–PF4–heparin IgG enzyme-linked immunosorbent assay (Photo courtesy of Arne Müseler)
Vaccine-induced immune thrombotic thrombocytopenia (VITT) has been described after vaccination with the adenoviral vector vaccines and can be confirmed by anti–PF4–heparin IgG enzyme-linked immunosorbent assay (Photo courtesy of Arne Müseler)
Vaccine-induced immune thrombotic thrombocytopenia (VITT) has been described after vaccination with the adenoviral vector vaccines. A syndrome characterized by venous or arterial thrombosis, particularly at unusual sites including cerebral sinus venous thrombosis (CSVT)/splanchnic thrombosis, and mild to severe thrombocytopenia.

VITT is caused by platelet-activating anti–platelet factor 4 (PF4) IgG antibodies, the presence of which can be confirmed by anti–PF4–heparin IgG enzyme-linked immunosorbent assay (ELISA) in combination with PF4-enhanced washed-platelet–activation assays. Clinical and in vitro characteristics of acute VITT closely resemble (autoimmune) heparin-induced thrombocytopenia.

Medical Scientists at the Universitätsmedizin Greifswald (Greifswald, Germany) conducted a study involving 35 patients with serologically confirmed VITT (27 women and eight men; median age, 53 years [range, 18 to 77 years]). The patients’ clinical symptoms started between days five and 18 after vaccination. All the patients presented with thrombocytopenia, and 30 presented with thrombosis.

Anti-PF4 IgG antibodies were tested by PF4/heparin ELISA. The cut-off of the ELISA was defined as optical density (OD) 0.5; samples testing >0.5 - 1.0 were defined as positive, between >1.0 - 2.0 as strongly–positive; greater 2.0 OD were defined as very strongly positive. Platelet activation by the antibodies was tested in a PF4-dependent washed platelet assay. Negatively tested sera were repeated with a new panel of washed platelets on a different day. A positive result was defined as PF4-dependent activation of platelets (lag time, <30 min) of at least two of three different donors.

The scientists reported that results of the PF4-dependent platelet-activation assay became negative in 23 of 35 patients (66%). In 14 of the 15 patients (93%), with follow-up of more than 12 weeks the platelet-activation assay became negative within a median of 12 weeks. In addition, the median optical density on anti–PF4–heparin IgG ELISA declined by 53% between the first and last available blood samples (median optical density, 2.98 versus 1.39). However, full seroreversion to a negative ELISA result (i.e., an optical density of <0.5) was seen in only three patients. In one patient, PF4-dependent platelet-activating antibodies and ELISA optical density values of greater than 3.0 persisted for more than 12 weeks in association with recurrent episodes of thrombocytopenia.

The authors reported that to achieve full protection against coronavirus disease 2019 (Covid-19), a second vaccination is needed after a first dose of ChAdOx1 nCoV-19. On the basis of their small series of patients, subsequent vaccination with an mRNA vaccine appears to be safe after results of platelet-activation assays for VITT antibodies have become negative. When no platelet-activation assay is available, a substantial decline in the optical density on anti–PF4–heparin IgG ELISA may be used as a decision criterion. The study was published on September 8, 2021 in The New England Journal of Medicine.

Related Links:

Universitätsmedizin Greifswald

Gold Member
Respiratory Syncytial Virus Test
OSOM® RSV Test
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Laboratory Software
ArtelWare
Capillary Blood Collection Tube
IMPROMINI M3

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more