Globotriaosylsphingosine Levels Measured in Fabry Disease Patients

By LabMedica International staff writers
Posted on 08 Sep 2021
Image: The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses (Photo courtesy of SCIEX)
Image: The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses (Photo courtesy of SCIEX)
Fabry disease (FD) is caused by an inborn error of glycosphingolipid metabolism, a genetic defect resulting in partial or complete deficiency of the lysosomal hydrolase alpha-galactosidase A (alpha-Gal A). This enzyme is responsible for breaking down glycolipids such as globotriaosylceramide and its deacylated derivative, globotriaosylsphingosine (LysoGb3).

In males, the classical Fabry phenotype generally arises in the pediatric age with acroparesthesia, hypo- or anhidrosis, angiokeratoma, corneal opacities (typically cornea verticillata) and microalbuminuria. Recently, LysoGb3 was found to be a useful biomarker in confirming FD diagnosis even in symptomatic females with normal or borderline leukocyte enzyme activity due to the effect of X-chromosome inactivation.

Clinical Scientists at the Meyer Children Hospital (Florence, Italy) and their colleagues carried out a prospective observational study enrolling 104 FD patients, 39 males and 65 females between the ages of 4 and 75 years from six clinical centers in Italy. Venous blood was collected. A portion was spotted onto filter paper (DBS) and another portion separated to obtain plasma.

The LysoGb3 concentrations in DBS and plasma were determined by highly sensitive electrospray ionization liquid chromatography tandem mass spectrometry. The data were obtained using an API 5500 QTRAP mass spectrometer (AB SCIEX, Concord, ON, Canada) equipped with Turbo Ion Spray source and operating in MRM positive ion mode. Chromatographic separation was achieved using an Agilent 1290 Infinity UHPLC capillary system (Agilent Technologies, Santa Clara, CA, USA).

The scientists reported that the method using DBS was validated by evaluating its precision, accuracy, matrix effect, recovery, and stability. Mean (±SEM) plasma and DBS levels of LysoGb3 in the 30 males with classical FD were 45.6 ± 9.2 and 40.6 ± 9.0 nmol/L, respectively, while in the nine males with late-onset FD, they were 9.2 ± 3.2 and 7.9 ± 2.4 nmol/L, respectively. Mean LysoGb3 levels in 54 females with a GLA variant associated with classical FD were 7.1 ± 0.6 (plasma) and 6.4 ± 0.5 nmol/L (DBS), while in the nine females with a GLA variant associated with late-onset FD LysoGb3 levels were 1.9 ± 0.7 (plasma) and 1.8 ± 0.5 nmol/L (DBS). There was a strong correlation between plasma and the corresponding DBS LysoGb3 concentrations, with few exceptions. Discrepancies were observed in anemic patients with typically low hematocrit levels compared to the normal range.

The authors concluded that the method proved to be efficient for the rapid analysis of LysoGb3. DBS provides a convenient, sensitive, and reproducible method for measuring LysoGb3 levels for diagnosis, initial phenotypic assignment, and therapeutic monitoring in patients with FD. The study was published on August 26, 2021 in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Meyer Children Hospital
AB SCIEX
Agilent Technologies


Gold Member
Collection and Transport System
PurSafe Plus®
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gold Member
Hybrid Pipette
SWITCH
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more