Globotriaosylsphingosine Levels Measured in Fabry Disease Patients

By LabMedica International staff writers
Posted on 08 Sep 2021
Print article
Image: The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses (Photo courtesy of SCIEX)
Image: The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses (Photo courtesy of SCIEX)
Fabry disease (FD) is caused by an inborn error of glycosphingolipid metabolism, a genetic defect resulting in partial or complete deficiency of the lysosomal hydrolase alpha-galactosidase A (alpha-Gal A). This enzyme is responsible for breaking down glycolipids such as globotriaosylceramide and its deacylated derivative, globotriaosylsphingosine (LysoGb3).

In males, the classical Fabry phenotype generally arises in the pediatric age with acroparesthesia, hypo- or anhidrosis, angiokeratoma, corneal opacities (typically cornea verticillata) and microalbuminuria. Recently, LysoGb3 was found to be a useful biomarker in confirming FD diagnosis even in symptomatic females with normal or borderline leukocyte enzyme activity due to the effect of X-chromosome inactivation.

Clinical Scientists at the Meyer Children Hospital (Florence, Italy) and their colleagues carried out a prospective observational study enrolling 104 FD patients, 39 males and 65 females between the ages of 4 and 75 years from six clinical centers in Italy. Venous blood was collected. A portion was spotted onto filter paper (DBS) and another portion separated to obtain plasma.

The LysoGb3 concentrations in DBS and plasma were determined by highly sensitive electrospray ionization liquid chromatography tandem mass spectrometry. The data were obtained using an API 5500 QTRAP mass spectrometer (AB SCIEX, Concord, ON, Canada) equipped with Turbo Ion Spray source and operating in MRM positive ion mode. Chromatographic separation was achieved using an Agilent 1290 Infinity UHPLC capillary system (Agilent Technologies, Santa Clara, CA, USA).

The scientists reported that the method using DBS was validated by evaluating its precision, accuracy, matrix effect, recovery, and stability. Mean (±SEM) plasma and DBS levels of LysoGb3 in the 30 males with classical FD were 45.6 ± 9.2 and 40.6 ± 9.0 nmol/L, respectively, while in the nine males with late-onset FD, they were 9.2 ± 3.2 and 7.9 ± 2.4 nmol/L, respectively. Mean LysoGb3 levels in 54 females with a GLA variant associated with classical FD were 7.1 ± 0.6 (plasma) and 6.4 ± 0.5 nmol/L (DBS), while in the nine females with a GLA variant associated with late-onset FD LysoGb3 levels were 1.9 ± 0.7 (plasma) and 1.8 ± 0.5 nmol/L (DBS). There was a strong correlation between plasma and the corresponding DBS LysoGb3 concentrations, with few exceptions. Discrepancies were observed in anemic patients with typically low hematocrit levels compared to the normal range.

The authors concluded that the method proved to be efficient for the rapid analysis of LysoGb3. DBS provides a convenient, sensitive, and reproducible method for measuring LysoGb3 levels for diagnosis, initial phenotypic assignment, and therapeutic monitoring in patients with FD. The study was published on August 26, 2021 in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Meyer Children Hospital
AB SCIEX
Agilent Technologies


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more