Toxoplasmic Encephalitis in HIV Patients Detected in Urine
By LabMedica International staff writers Posted on 25 Mar 2021 |

Image: The EASY-nLC 1200 HPLC, high-throughput capacity in a nano-flow UHPLC (Photo courtesy of Thermo Fisher Scientific)
Toxoplasma encephalitis (TE) is the most commonly reported neurological opportunistic infection in human immunodeficiency virus (HIV)-infected patients since the introduction of combination ART (cART). Diagnosis of TE is challenging under the best clinical circumstances.
The poor clinical sensitivity of quantitative polymerase chain reaction (qPCR) for Toxoplasma gondii in blood and cerebrospinal fluid (CSF) and the limited availability of molecular diagnostics and imaging technology leaves clinicians in resource-limited settings with few options other than empiric treatment.
An international team of scientists led by the University of Illinois Chicago (Chicago, IL, USA) recruited in a study 164 HIV positive patients from Peru and Bolivia and 51 ambulatory HIV/T. gondii positive patients for controls. Blood and urine specimens were taken at enrollment, which for most hospitalized patients was shortly after admission; remnant CSF was collected if the subject underwent lumbar puncture as part of their medical care. CD4 and CD8 cell counts and viral loads were abstracted from participants’ charts.
The investigators have described a proof of concept for novel urine diagnostics for TE using Poly-N-isoproplyacrylamide nanoparticles dyed with Reactive Blue-221 to concentrate antigens, substantially increasing the limit of detection. After nanoparticle-concentration, a standard western blotting technique with a monoclonal antibody was used for antigen detection. Toxoplasma gondii IgG serological status was determined with an in-house enzyme linked immunosorbent assay (ELISA). For qPCR, target sequences were amplified using a Light Cycler (Applied Biosciences, Foster City, CA, USA). Digested samples were analyzed by parallel-reaction-monitoring (PRM) on an Orbitrap Fusion mass spectrometer with a nanospray EASY-nLC 1200 HPLC (Thermo Fisher Scientific, Waltham, MA, USA).
The team reported that the limit of detection (LoD) of T. gondii antigens GRA1 and SAG1 was 7.8pg/mL and 31.3pg/mL, respectively. To characterize this diagnostic approach, 164 hospitalized HIV-infected patients with neurological symptoms compatible with TE were tested for 1) T. gondii serology (121/147, positive samples/total samples tested), 2) qPCR in cerebrospinal fluid (11/41), 3) qPCR in blood (10/112), and 4) urinary GRA1 (30/164) and SAG1 (12/164). GRA1 appears to be superior to SAG1 for detection of TE antigens in urine. Fifty-one HIV-infected, T. gondii seropositive but asymptomatic persons all tested negative by nanoparticle western blot and blood qPCR, suggesting the test has good specificity for TE for both GRA1 and SAG1. In a subgroup of 44 patients, urine samples were assayed with mass spectrometry PRM for the presence of T. gondii antigens. PRM identified antigens in eight samples, six of which were concordant with the urine diagnostic.
The authors concluded that their results demonstrate nanoparticle technology’s potential for a noninvasive diagnostic test for TE and that GRA1 is a promising target for antigen based diagnostics for TE. The study was published on March 2, 2021 in the journal PLOS Neglected Tropical Diseases.
Related Links:
University of Illinois Chicago
Applied Biosciences
Thermo Fisher Scientific
The poor clinical sensitivity of quantitative polymerase chain reaction (qPCR) for Toxoplasma gondii in blood and cerebrospinal fluid (CSF) and the limited availability of molecular diagnostics and imaging technology leaves clinicians in resource-limited settings with few options other than empiric treatment.
An international team of scientists led by the University of Illinois Chicago (Chicago, IL, USA) recruited in a study 164 HIV positive patients from Peru and Bolivia and 51 ambulatory HIV/T. gondii positive patients for controls. Blood and urine specimens were taken at enrollment, which for most hospitalized patients was shortly after admission; remnant CSF was collected if the subject underwent lumbar puncture as part of their medical care. CD4 and CD8 cell counts and viral loads were abstracted from participants’ charts.
The investigators have described a proof of concept for novel urine diagnostics for TE using Poly-N-isoproplyacrylamide nanoparticles dyed with Reactive Blue-221 to concentrate antigens, substantially increasing the limit of detection. After nanoparticle-concentration, a standard western blotting technique with a monoclonal antibody was used for antigen detection. Toxoplasma gondii IgG serological status was determined with an in-house enzyme linked immunosorbent assay (ELISA). For qPCR, target sequences were amplified using a Light Cycler (Applied Biosciences, Foster City, CA, USA). Digested samples were analyzed by parallel-reaction-monitoring (PRM) on an Orbitrap Fusion mass spectrometer with a nanospray EASY-nLC 1200 HPLC (Thermo Fisher Scientific, Waltham, MA, USA).
The team reported that the limit of detection (LoD) of T. gondii antigens GRA1 and SAG1 was 7.8pg/mL and 31.3pg/mL, respectively. To characterize this diagnostic approach, 164 hospitalized HIV-infected patients with neurological symptoms compatible with TE were tested for 1) T. gondii serology (121/147, positive samples/total samples tested), 2) qPCR in cerebrospinal fluid (11/41), 3) qPCR in blood (10/112), and 4) urinary GRA1 (30/164) and SAG1 (12/164). GRA1 appears to be superior to SAG1 for detection of TE antigens in urine. Fifty-one HIV-infected, T. gondii seropositive but asymptomatic persons all tested negative by nanoparticle western blot and blood qPCR, suggesting the test has good specificity for TE for both GRA1 and SAG1. In a subgroup of 44 patients, urine samples were assayed with mass spectrometry PRM for the presence of T. gondii antigens. PRM identified antigens in eight samples, six of which were concordant with the urine diagnostic.
The authors concluded that their results demonstrate nanoparticle technology’s potential for a noninvasive diagnostic test for TE and that GRA1 is a promising target for antigen based diagnostics for TE. The study was published on March 2, 2021 in the journal PLOS Neglected Tropical Diseases.
Related Links:
University of Illinois Chicago
Applied Biosciences
Thermo Fisher Scientific
Latest Immunology News
- Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
- Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
- Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions
- Cerebrospinal Fluid Test Predicts Dangerous Side Effect of Cancer Treatment
- New Test Measures Preterm Infant Immunity Using Only Two Drops of Blood
- Simple Blood Test Could Help Choose Better Treatments for Patients with Recurrent Endometrial Cancer
- Novel Analytical Method Tracks Progression of Autoimmune Diseases
- 3D Bioprinted Gastric Cancer Model Uses Patient-Derived Tissue Fragments to Predict Drug Response
- Blood Test for Fungal Infections Could End Invasive Tissue Biopsies
- Cutting-Edge Microscopy Technology Enables Tailored Rheumatology Therapies
- New Discovery in Blood Immune Cells Paves Way for Parkinson's Disease Diagnostic Test
- AI Tool Uses Routine Blood Tests to Predict Immunotherapy Response for Various Cancers
- Blood Test Can Predict How Long Vaccine Immunity Will Last
- Microfluidic Chip-Based Device to Measure Viral Immunity
Channels
Clinical Chemistry
view channel
Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse
Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more
‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection
Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more
Low-Cost Portable Screening Test to Transform Kidney Disease Detection
Millions of individuals suffer from kidney disease, which often remains undiagnosed until it has reached a critical stage. This silent epidemic not only diminishes the quality of life for those affected... Read more
New Method Uses Pulsed Infrared Light to Find Cancer's 'Fingerprints' In Blood Plasma
Cancer diagnoses have traditionally relied on invasive or time-consuming procedures like tissue biopsies. Now, new research published in ACS Central Science introduces a method that utilizes pulsed infrared... Read moreMolecular Diagnostics
view channel
Genetic-Based Tool Predicts Survival Outcomes of Pancreatic Cancer Patients
A tumor marker is a substance found in the body that may signal the presence of cancer. These substances, which can include proteins, genes, molecules, or other biological compounds, are either produced... Read more
Urine Test Diagnoses Early-Stage Prostate Cancer
Prostate cancer is one of the leading causes of death among men worldwide. A major challenge in diagnosing the disease is the absence of reliable biomarkers that can detect early-stage tumors.... Read moreHematology
view channel
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read more
Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
In the United States, approximately 15% of pregnant individuals are RhD-negative. However, in about 40% of these cases, the fetus is also RhD-negative, making the administration of RhoGAM unnecessary.... Read moreImmunology
view channel
Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more
Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
Chimeric antigen receptor (CAR) T-cell therapy has emerged as one of the most promising recent developments in the treatment of blood cancers. However, over half of non-Hodgkin lymphoma (NHL) patients... Read morePathology
view channel
AI-Based Model Predicts Kidney Cancer Therapy Response
Each year, nearly 435,000 individuals are diagnosed with clear cell renal cell carcinoma (ccRCC), making it the most prevalent subtype of kidney cancer. When the disease spreads, anti-angiogenic therapies... Read more
Sensitive and Specific DUB Enzyme Assay Kits Require Minimal Setup Without Substrate Preparation
Ubiquitination and deubiquitination are two important physiological processes in the ubiquitin-proteasome system, responsible for protein degradation in cells. Deubiquitinating (DUB) enzymes contain around... Read moreTechnology
view channel
Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses
Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more
Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples
As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more
Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more
Innovative, Label-Free Ratiometric Fluorosensor Enables More Sensitive Viral RNA Detection
Viruses present a major global health risk, as demonstrated by recent pandemics, making early detection and identification essential for preventing new outbreaks. While traditional detection methods are... Read moreIndustry
view channel
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more