LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Direct Oral Anticoagulants Determined by RDT in Urine Samples

By LabMedica International staff writers
Posted on 10 Feb 2020
Image: The DOAC dipstick is a diagnostic urine test strip, which is intended for qualitative detection of the absence or presence of direct oral anticoagulants (DOACs: Dabigatran, Apixaban, Edoxaban and Rivaroxaban) in human urine by visual identification of colors (Photo courtesy of DOASENSE GmbH).
Image: The DOAC dipstick is a diagnostic urine test strip, which is intended for qualitative detection of the absence or presence of direct oral anticoagulants (DOACs: Dabigatran, Apixaban, Edoxaban and Rivaroxaban) in human urine by visual identification of colors (Photo courtesy of DOASENSE GmbH).
The rapid determination of the presence of direct oral anticoagulants (DOACs) in a patient remains a major challenge in emergency medicine and for rapid medical treatment decisions. All DOACs are excreted into urine.

Emergency situations with a need for point-of-care testing for the presence or absence of DOACs include emergent or urgent major surgical interventions, clinically relevant bleeding, or thrombotic episodes with known or unknown anticoagulant therapy, as well as the evaluation of unconscious patients or those unable to inform clinicians about their anticoagulant therapy.

An international team of scientists led by the Ruprecht Karls University of Heidelberg (Heidelberg, Germany) carried out a prospective, open-label, controlled, nonrandomized, multicenter study in Germany on subjects treated with a DXI (apixaban, edoxaban, and rivaroxaban) or the DTI dabigatran were included. The subjects were recruited from 18 outpatient care units specialized in oral anticoagulation.

Urine samples (4 mL) were transferred into polyethylene terephthalate tubes (V-Monovette Urine Z 4mL, Sarstedt AG, Nümbrecht, Germany) using plastic syringes. The DOAC Dipstick test (DOASENSE GmbH, Heidelberg, Germany) was performed on the urine sample at the time of collection by site personnel. Next, barcodes were attached to the duplicate samples and recorded in the case report form. The samples were frozen immediately at –25 °C, transferred without interrupting the cold chain to a central laboratory for LC-MS/MS analysis. The chromatography system consisted of an ACQUITY H-Class UPLC System connected to an Autosampler, quaternary HPLC-Pump, Xevo TQ-S mass spectrometry detector, and a CSH C18 Column (Waters GmbH, Eschborn, Germany).

Nine hundred and fourteen subjects were included and 880 were evaluated per protocol (451 factor Xa inhibitors apixaban, edoxaban, and rivaroxaban, 429 thrombin inhibitor dabigatran) at 18 centers. The sensitivity, specificity, accuracy, and predictive values and agreement between methods for determination of factor Xa inhibitors were at least noninferior to 95% with a 0.5% margin and of thrombin inhibitor superior to 97.5%. These results were compared with LC-MS/MS results in the intention-to-analyze cohort. The receiver operating curve showed c-values of 0.989 (factor Xa inhibitors) and 0.995 (thrombin inhibitor). Visual evaluation of the factor Xa and thrombin inhibitor pads was not different between centers.

The authors concluded that the present study shows that DOAC Dipstick test sensitively and specifically determines the presence of both Xa and IIa inhibitors in urine samples, if compared with the gold standard of LC-MS/MS. The evaluation of the DOAC Dipstick test in emergency medicine and other patient groups is ongoing. The study was published in the January 2020 issue of the journal Thrombosis and Haemostasis.

Related Links:
Ruprecht Karls University of Heidelberg
Sarstedt AG
DOASENSE GmbH
Waters GmbH


Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gold Member
Immunochromatographic Assay
CRYPTO Cassette
HBV DNA Test
GENERIC HBV VIRAL LOAD VER 2.0

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more