Urinary Hydration Markers Tested for Storage Condition Validity

By LabMedica International staff writers
Posted on 27 Aug 2019
Image: The 3320 osmometer used to assess urine osmolality, a measure of urine concentration and hydration (Photo courtesy of Advanced Instruments).
Image: The 3320 osmometer used to assess urine osmolality, a measure of urine concentration and hydration (Photo courtesy of Advanced Instruments).
Fluid balance is an aspect of the homeostasis of organisms in which the amount of water in the organism needs to be controlled, via osmoregulation and behavior, such that the concentrations of electrolytes in the various body fluids are kept within healthy ranges.

The human kidneys will normally adjust to varying levels of water intake. The kidneys will require time to adjust to the new water intake level. This can cause someone who drinks a lot of water to become dehydrated more easily than someone who routinely drinks less. Analysis of urine specimens is widely utilized to determine day-to-day hydration status in individuals as well as for other markers of health.

Scientists at the University of North Carolina at Greensboro (Greensboro, NC, USA) enrolled eight males and 13 females (mean ± SD; age, 24 ± 5 years; body mass, 68.9 ± 24.2 kg; height, 160.2 ± 32.1 cm) without a history of renal disease or currently taking any medications or supplements known to affect the accuracy of urinary hydration markers. Participants provided a 24 hour urine sample in a clean container with each urine sample being separate into four separate containers, two in each of the following temperatures: 7 °C and 22 °C. One specimen container at each temperature was either sealed using the manufacturers cap (single sealed, SS) or the manufacturers cap plus laboratory wrapping film (double sealed, DS).

Each sample was analyzed after 1, 2, 3, 7 and 10 days. Urine samples were assessed for urine osmolality (UOSMO), urine specific gravity (USG), and urine color (UCOL). UOSMO was stable at 7 °C for two days and three days for single sealed and double sealed containers, respectively. UOSMO was determined via freezing point depression with a 3320 osmometer. USG was measured using an optical refractometer that was accurate to ±0.001 AU and had a resolution of 0.0001. UCOL was measured by comparing each urine sample to an 8-point urine color chart where the sample was held against a white background in a well-lit room.

The team reported that USG measures were stable for singled sealed and double sealed for up to ten days when stored at 22 °C. UCOL measures were maintained for up to three days in all storage methods. For refrigerated samples, UOSMO measures for samples stored in SS containers became significantly elevated three days following baseline measures, whereas UOSMO measures for samples stored in DS containers became significantly elevated seven days following baseline measures. Conversely to UOSMO, USG measures were significantly elevated in SS and DS samples stored at 7 °C beginning one day following baseline measures, compared to SS and DS samples stored at 20 °C.

The authors concluded that to achieve optimal results, it is recommended that 24-hour urine samples are assessed immediately for the respective hydration markers being analyzed. If immediate analysis is unavailable, such as in the case of field based or longitudinal research, it is recommended that 24-hour urine samples are stored in a refrigerated environment and hydration markers (UOSMO and UCOL) be assessed within 48 hours. The study was published on August 5, 2019, in the journal PLOS ONE.

Related Links:
University of North Carolina at Greensboro

Gold Member
Collection and Transport System
PurSafe Plus®
POC Helicobacter Pylori Test Kit
Hepy Urease Test
CBM Analyzer
Complete Blood Morphology (CBM) Analyzer
Gold Member
Hematology Analyzer
Medonic M32B

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more