Low-Volume Aldosterone Immunoassay Validated for Small Samples

By LabMedica International staff writers
Posted on 26 Sep 2017
Print article
Image: The infinite F50 absorbance reader (Photo courtesy of Tecan).
Image: The infinite F50 absorbance reader (Photo courtesy of Tecan).
Heart failure is a severe cardiovascular disease in adults and children and is characterized by structural or functional abnormalities of the heart. Heart failure leads to an inappropriate blood circulation and subsequently to an undersupply of metabolizing tissues with oxygen and nutrients.

The humoral parameter aldosterone is part of the renin-angiotensin-aldosterone system (RAAS), which plays a major role in the body's salt and water balance. In clinical settings, serum aldosterone is recommended as a screening and diagnosis parameter for primary aldosteronism in high-risk patients.

Scientists at the Heinrich-Heine-University Düsseldorf (Germany) developed and validated a bioanalytical assay for the determination of aldosterone concentrations in small sample volumes. An immunoassay was developed based on a commercially available aldosterone enzyme-linked immunosorbent assay (ELISA) kit. Serum samples were donated by healthy volunteers. The optical density was measured using the absorbance reader infinite F50.

The investigators reported that the assay with a range 31.3 pg/mL to 1,000 pg/mL (86.9 pmol/L to 2,775 pmol/L) was characterized by a between-run accuracy from − 3.8% to − 0.8% and a between-run imprecision ranging from 4.9% to 8.9% (coefficient of variation). For within-run accuracy, the relative error was between − 11.1% and + 9.0%, while within-run imprecision ranged from 1.2% to 11.8% (CV). For parallelism and dilutional linearity, the relative error of back-calculated concentrations varied from − 14.1% to + 8.4% and from − 7.4% to + 10.5%, respectively. No impact of hemolysis on accurate sample determinations was observed.

The authors concluded that their present immunoassay is compliant with current bioanalytical guidelines of the European Medicines Agency (EMA) and allows accurate and precise aldosterone determinations in 40 µL serum. As the assay runs with low-volume samples, it is especially valuable for pediatric investigations, but is not limited to this population. The study was published originally published online on July 27, 2017, in the journal Practical Laboratory Medicine.

Related Links:
Heinrich-Heine-University Düsseldorf


Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Biological Indicator Vials
BI-O.K.
New
Malaria Test
STANDARD Q Malaria P.f/Pan Ag

Print article

Channels

Clinical Chemistry

view channel
Image: The research team has developed the uCR-Chip device to enhance kidney function testing (Photo courtesy of University of Manitoba)

Low-Cost Portable Screening Test to Transform Kidney Disease Detection

Millions of individuals suffer from kidney disease, which often remains undiagnosed until it has reached a critical stage. This silent epidemic not only diminishes the quality of life for those affected... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Pathology

view channel
Image: The UV absorbance spectrometer being used to measure the absorbance spectra of cell culture samples (Photo courtesy of SMART CAMP)

Novel UV and Machine Learning-Aided Method Detects Microbial Contamination in Cell Cultures

Cell therapy holds great potential in treating diseases such as cancers, inflammatory conditions, and chronic degenerative disorders by manipulating or replacing cells to restore function or combat disease.... Read more

Technology

view channel
Image: Schematic illustration of the chip (Photo courtesy of Biosensors and Bioelectronics, DOI: https://doi.org/10.1016/j.bios.2025.117401)

Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples

Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.