Quantitative Fetomaternal Hemorrhage Assessed with Lab Tests
By LabMedica International staff writers Posted on 06 Oct 2016 |

Image: The COULTER AcT diff2 hematology analyzer (Photo courtesy of Beckman Coulter).
Fetomaternal hemorrhage (FMH) assessment is usually used to determine anti-D immunoglobulin dose in postpartum prophylaxis of the hemolytic disease of the fetus and newborn (HDFN).
In maternal blood, fetal red blood cells (RBCs) can be identified due to the differences between them and adult RBCs and these are fetal hemoglobin (HbF) presence, lack of the carbonic anhydrase (CA), and the presence of particular group antigen.
Scientists at the Centre of Postgraduate Medical Education (Warsaw, Poland) collected blood samples on EDTA as follows: 20 RhD-negative blood donors samples to evaluate test specificity, 18 RhD-negative blood donors and 18 RhD-positive cord blood samples to prepare mixtures imitating FMH from 0.1% to 5%, and 14 weak D blood donors samples to evaluate test specificity with anti-D antibodies and to perform 20 suspensions with the RBCs of 10 RhD-positive blood donors. Blood samples from 98 women were tested: 74 from women just before labor and in 1 to 2 hours after it, 10 only before childbirth, including five before 40 weeks of pregnancy, due to fetal anemia, and 14 only after labor.
The amount and parameters of RBCs were measured with the COULTER AcT diff/diff2 Hematology Analyzer (Beckman Coulter, Brea, CA, USA) to prepare RBCs mixtures with the known percentage of fetal cells. The team used three flow cytometry methods including Antigen D staining, Hemoglobin F (HbF) staining and HbF and carbonic anhydrase (CA) staining. The flow cytometer was calibrated correctly and in all samples, 50,000 RBCs were analyzed using FACSCanto II and FACSDiva software (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). The scientists also carried out Kleihauer–Betke test (KBT), which is based on HbF resistance to acid elution while HbA is removed from cells.
The hematologists found that in all artificial mixtures with known concentrations, FCTs and KBT with counting 10,000 RBCs had similar satisfying sensitivity and specificity. KBT with counting 2000 RBCs had to be disqualified because of significant discrepancies between expected and measured values of FMH. The test procedure with anti-D was easier and shorter than the remaining tests, but it can be only used for FMH assessment in RhD-negative mothers with RhD-positive newborns. In one clinical sample, it was impossible to distinguish fetal RBCs from maternal F cells in KBT and FC with anti-HbF but other tests were useful.
The authors concluded that the methods that use flow cytometry and anti-HbF, anti-D, and anti-HbF + anti-CA antibodies, as well as microscopic Kleihauer–Betke test detecting HbF-positive blood cells, with counting 10 000 of RBCs, have similar satisfying sensitivity and specificity. In the four tests, correlation between expected and obtained results was appropriate. Each test had some advantage and limitation in any clinical situation. Therefore, it is best to have opportunity to perform two or three assays in the laboratory. The study was published in the August 2016 issue of the International Journal of Laboratory Hematology.
Related Links:
Centre of Postgraduate Medical Education
Beckman Coulter
BD
In maternal blood, fetal red blood cells (RBCs) can be identified due to the differences between them and adult RBCs and these are fetal hemoglobin (HbF) presence, lack of the carbonic anhydrase (CA), and the presence of particular group antigen.
Scientists at the Centre of Postgraduate Medical Education (Warsaw, Poland) collected blood samples on EDTA as follows: 20 RhD-negative blood donors samples to evaluate test specificity, 18 RhD-negative blood donors and 18 RhD-positive cord blood samples to prepare mixtures imitating FMH from 0.1% to 5%, and 14 weak D blood donors samples to evaluate test specificity with anti-D antibodies and to perform 20 suspensions with the RBCs of 10 RhD-positive blood donors. Blood samples from 98 women were tested: 74 from women just before labor and in 1 to 2 hours after it, 10 only before childbirth, including five before 40 weeks of pregnancy, due to fetal anemia, and 14 only after labor.
The amount and parameters of RBCs were measured with the COULTER AcT diff/diff2 Hematology Analyzer (Beckman Coulter, Brea, CA, USA) to prepare RBCs mixtures with the known percentage of fetal cells. The team used three flow cytometry methods including Antigen D staining, Hemoglobin F (HbF) staining and HbF and carbonic anhydrase (CA) staining. The flow cytometer was calibrated correctly and in all samples, 50,000 RBCs were analyzed using FACSCanto II and FACSDiva software (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). The scientists also carried out Kleihauer–Betke test (KBT), which is based on HbF resistance to acid elution while HbA is removed from cells.
The hematologists found that in all artificial mixtures with known concentrations, FCTs and KBT with counting 10,000 RBCs had similar satisfying sensitivity and specificity. KBT with counting 2000 RBCs had to be disqualified because of significant discrepancies between expected and measured values of FMH. The test procedure with anti-D was easier and shorter than the remaining tests, but it can be only used for FMH assessment in RhD-negative mothers with RhD-positive newborns. In one clinical sample, it was impossible to distinguish fetal RBCs from maternal F cells in KBT and FC with anti-HbF but other tests were useful.
The authors concluded that the methods that use flow cytometry and anti-HbF, anti-D, and anti-HbF + anti-CA antibodies, as well as microscopic Kleihauer–Betke test detecting HbF-positive blood cells, with counting 10 000 of RBCs, have similar satisfying sensitivity and specificity. In the four tests, correlation between expected and obtained results was appropriate. Each test had some advantage and limitation in any clinical situation. Therefore, it is best to have opportunity to perform two or three assays in the laboratory. The study was published in the August 2016 issue of the International Journal of Laboratory Hematology.
Related Links:
Centre of Postgraduate Medical Education
Beckman Coulter
BD
Latest Hematology News
- New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
- Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
- WBC Count Could Predict Severity of COVID-19 Symptoms
- New Platelet Counting Technology to Help Labs Prevent Diagnosis Errors
- Streamlined Approach to Testing for Heparin-Induced Thrombocytopenia Improves Diagnostic Accuracy
- POC Hemostasis System Could Help Prevent Maternal Deaths
- New Test Assesses Oxygen Delivering Ability of Red Blood Cells by Measuring Their Shape
- Personalized CBC Testing Could Help Diagnose Early-Stage Diseases in Healthy Individuals
- Non-Invasive Test Solution Determines Fetal RhD Status from Maternal Plasma
- First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC
- Next Gen CBC and Sepsis Diagnostic System Targets Faster, Earlier, Easier Results
- Newly Discovered Blood Group System to Help Identify and Treat Rare Patients
- Blood Platelet Score Detects Previously Unmeasured Risk of Heart Attack and Stroke
- Automated Benchtop System to Bring Blood Testing To Anyone, Anywhere
- New Hematology Analyzers Deliver Combined ESR and CBC/DIFF Results in 60 Seconds
- Next Generation Instrument Screens for Hemoglobin Disorders in Newborns
Channels
Clinical Chemistry
view channel
Carbon Nanotubes Help Build Highly Accurate Sensors for Continuous Health Monitoring
Current sensors can measure various health indicators, such as blood glucose levels, in the body. However, there is a need to develop more accurate and sensitive sensor materials that can detect lower... Read more
Paper-Based Device Boosts HIV Test Accuracy from Dried Blood Samples
In regions where access to clinics for routine blood tests presents financial and logistical obstacles, HIV patients are increasingly able to collect and send a drop of blood using paper-based devices... Read moreMolecular Diagnostics
view channel
D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism
Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more
New Biomarkers to Improve Early Detection and Monitoring of Kidney Injury
Drug-induced kidney injury, also known as nephrotoxicity, is a prevalent issue in clinical practice, occurring when specific medications at certain doses cause damage to the kidneys. Nephrotoxicity can... Read moreImmunology
view channel
Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions
In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read moreCerebrospinal Fluid Test Predicts Dangerous Side Effect of Cancer Treatment
In recent years, cancer immunotherapy has emerged as a promising approach where the patient's immune system is harnessed to fight cancer. One form of immunotherapy, called CAR-T-cell therapy, involves... Read more
New Test Measures Preterm Infant Immunity Using Only Two Drops of Blood
Preterm infants are particularly vulnerable due to their organs still undergoing development, which can lead to difficulties in breathing, eating, and regulating body temperature. This is especially true... Read more
Simple Blood Test Could Help Choose Better Treatments for Patients with Recurrent Endometrial Cancer
Endometrial cancer, which develops in the lining of the uterus, is the most prevalent gynecologic cancer in the United States, affecting over 66,000 women annually. Projections indicate that in 2025, around... Read moreMicrobiology
view channel
Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours
Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read moreInnovative ID/AST System to Help Diagnose Infectious Diseases and Combat AMR
Each year, 11 million people across the world die of sepsis out of which 1.3 million deaths are due to antibiotic-resistant bacteria. The burden of antimicrobial resistance (AMR) continues to weigh heavily,... Read more
Gastrointestinal Panel Delivers Rapid Detection of Five Common Bacterial Pathogens for Outpatient Use
Acute infectious gastroenteritis results in approximately 179 million cases each year in the United States, leading to a significant number of outpatient visits and hospitalizations. To address this, a... Read morePathology
view channel
AI Model Predicts Patient Response to Bladder Cancer Treatment
Each year in the United States, around 81,000 new cases of bladder cancer are diagnosed, leading to approximately 17,000 deaths annually. Muscle-invasive bladder cancer (MIBC) is a severe form of bladder... Read more
New Laser-Based Method to Accelerate Cancer Diagnosis
Researchers have developed a method to improve cancer diagnostics and other diseases. Collagen, a key structural protein, plays various roles in cell activity. A novel multidisciplinary study published... Read more
New AI Model Predicts Gene Variants’ Effects on Specific Diseases
In recent years, artificial intelligence (AI) has greatly enhanced our ability to identify a vast number of genetic variants in increasingly larger populations. However, up to half of these variants are... Read more
Powerful AI Tool Diagnoses Coeliac Disease from Biopsy Images with Over 97% Accuracy
Coeliac disease is an autoimmune disorder triggered by the consumption of gluten, causing symptoms such as stomach cramps, diarrhea, skin rashes, weight loss, fatigue, and anemia. Due to the wide variation... Read moreTechnology
view channel
Smartphones Could Diagnose Diseases Using Infrared Scans
Rapid advancements in technology may soon make it possible for individuals to bypass invasive medical procedures by simply uploading a screenshot of their lab results from their phone directly to their doctor.... Read more
Novel Sensor Technology to Enable Early Diagnoses of Metabolic and Cardiovascular Disorders
Metabolites are critical compounds that fuel life's essential functions, playing a key role in producing energy, regulating cellular activities, and maintaining the balance of bodily systems.... Read more
3D Printing Breakthrough Enables Large Scale Development of Tiny Microfluidic Devices
Microfluidic devices are diagnostic systems capable of analyzing small volumes of materials with precision and speed. These devices are used in a variety of applications, including cancer cell analysis,... Read moreIndustry
view channel
Tecan Acquires ELISA Immunoassay Assets from Revvity's Cisbio Bioassays
Tecan Group (Männedorf, Switzerland) has entered into an agreement to acquire certain assets relating to key ELISA immunoassay products from Cisbio Bioassays SAS (Codolet, France), a subsidiary of the... Read more