Immunoassay Evaluated for Quantitative Measurement of Fecal α1-Antitrypsin

By LabMedica International staff writers
Posted on 09 Aug 2016
Image: The SPECTRAmax PLUS plate reader (Photo courtesy of Molecular Devices).
Image: The SPECTRAmax PLUS plate reader (Photo courtesy of Molecular Devices).
The measurement of the protease α1-antitrypsin (A1A) in stool specimens can be used to detect the presence of serum proteins in the gastrointestinal tract a sign of protein-losing enteropathy (PLE).

The major causes of PLE can be divided into erosive and non-erosive gastrointestinal disorders, as well as increased central venous pressure or mesenteric lymphatic obstruction and among such disorders are enteritis, Crohn disease, ulcerative colitis, and celiac disease.

Scientists at the Associated Regional and University Pathologists (ARUP) Laboratories (Salt Lake City, UT, USA) used residual stool specimens sent to ARUP laboratories for fecal A1A testing, as well as paired sera and timed stool samples obtained from healthy volunteers. A1A in stool was measured with a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA). Assay imprecision, analytical sensitivity, linearity, accuracy, analyte stability, and reference intervals were determined.

Stool A1A was measured by using the Human α1-Antitrypsin ELISA (ImmuChrom, Heppenheim, Germany). This assay is a polyclonal immunometric method used for quantifying the A1A extracted from stool. Signals for ELISA plates were quantified with a SPECTRAmax PLUS plate reader (Molecular Devices LLC, Sunnyvale, CA, USA). Reference intervals for stool A1A and A1A clearance were established using timed stool samples and sera collected from 124 healthy volunteers (62 males, 62 females; ages 19–61 years).

The investigators found that the limit of quantification of the ELISA method used was 2.0 ng/mL, and the assay was linear to 85 ng/mL. The mean recovery of A1A added to samples was 108.2% and A1A was stable in stool for a minimum of two days, seven days, and three months at room temperature, 4 °C to 8 °C and −20 °C, respectively. The upper 95th percentile reference limits for A1A in stool and A1A clearance were 0.48 mg/g and 49 mL/day, respectively.

The authors concluded that the ImmuChrom human A1A ELISA demonstrates acceptable performance characteristics for quantifying A1A in stool extracts. Furthermore, this stool ELISA may be used in combination with the Tina-Quant A1A serum assay (Roche Diagnostics, Basel Switzerland) to assess A1A clearance for diagnosing and monitoring PLE. The study was published in the July 2016 issue of the Journal of Applied Laboratory Medicine.

Related Links:
Associated Regional and University Pathologists Laboratories
ImmuChrom
Molecular Devices
Roche Diagnostics
Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
ESR Analyzer
TEST1 2.0
8-Channel Pipette
SAPPHIRE 20–300 µL

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more