LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Enzyme Assay on Impregnated Filter Paper Detects Krabbe Disease

By LabMedica International staff writers
Posted on 26 Jan 2015
Image: The SpectraMax M2 spectrofluorometer (Photo courtesy of Molecular Devices).
Image: The SpectraMax M2 spectrofluorometer (Photo courtesy of Molecular Devices).
Image: The Misonix Sonicator XL2020 (Photo courtesy of Qsonica).
Image: The Misonix Sonicator XL2020 (Photo courtesy of Qsonica).
Krabbe disease (KD) is an inherited lysosomal storage disease (LSD) caused by the deficiency of galactocerebrosidase (GALC) and is characterized by a severe and progressive leukodystrophy with death frequently before one year of life.

Dried-blood filter paper (DBFP) samples have been increasingly used for lysosomal enzyme assay and some lysosomal enzymes could not be tested in DBFP samples using fluorometric assays, including GALC, heparan-sulfamidase and a few others.

Medical Geneticists at the Hospital de Clínicas de Porto Alegre (Brazil) obtained leucocytes from healthy individuals and confirmed KD patients. Dried-leukocytes filter paper (DLFP) samples were prepared by diluting a pellet of leukocytes in distilled water and the solution was mixed, sonicated on ice bath in a Misonix Sonicator XL2020 (Qsonica; Newtown, CT, USA). After incubation with suitable substrates supernatants were measured on SpectraMax M2 spectrofluorometer (Molecular Devices; Sunnyvale, CA, USA).

When GALC activities in DLFP and their corresponding leukocyte samples were compared, it is possible to see a close correlation in the respective KD groups. The healthy control group showed higher values of activities in DLFP, possibly due to some degree of protein retention in the filter paper in the dilution process. The investigators did not visualize this effect in the KD samples, probably because the fluorescence of these samples is very low. Nevertheless, the assay in DLFP allowed the correct identification of KD patients in all cases.

The authors concluded that the assay of GALC on DLFP is a reliable and useful method for the identification of KD. As sample preparation is feasible in standard biochemical laboratories and as transportation is very simple, it could enable patients living in remote areas to be investigated and diagnosed. The study was published on January 1, 2015, in the journal Clinica Chimica Acta.

Related Links:

Hospital de Clínicas de Porto Alegre
Qsonica
Molecular Devices


Gold Member
Immunochromatographic Assay
CRYPTO Cassette
POC Helicobacter Pylori Test Kit
Hepy Urease Test
8-Channel Pipette
SAPPHIRE 20–300 µL
Gold Member
Hybrid Pipette
SWITCH

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more