Automated Methods Evaluated for Von Willebrand Factor Activity

By LabMedica International staff writers
Posted on 12 Jun 2014
Image: The Sysmex CS2000i fully automated blood coagulation analyzer (Photo courtesy of Siemens).
Image: The Sysmex CS2000i fully automated blood coagulation analyzer (Photo courtesy of Siemens).
Von Willebrand factor (VWF) assays have an important role in the diagnostic evaluation, and treatment monitoring, of von Willebrand disease (VWD), which is one of the most common coagulopathies or bleeding disorders.

The laboratory evaluation for VWD requires an assessment of plasma VWF activity, which is commonly done using an aggregometer to assess VWF ristocetin cofactor activity which is a quantitative method that uses the antibiotic ristocetin to induce plasma VWF binding to the VWF receptor on target platelets and platelet agglutination.

Scientists at the McMaster University (Hamilton, ON, Canada) evaluated 262 samples from 217 patients that included 188 samples from 153 females and 73 samples from 63 males. There were 197 samples from adults (ages 18 to 84) and 64 from children (ages 0 to 17 years), and 67 samples were from 34 patients with previously diagnosed VWD. After validating that the assay could be performed on an instrument from a different manufacturer, they compared VWF activity assay (VWF:Ac) to VWF ristocetin cofactor activity (VWF:RCo) findings, including ratios of activity/antigen.

Plasma was tested by the VWF:Ac on an STA-R Evolution (Diagnostica Stago; Parsippany, NJ, USA) and using the Innovance assay on a Sysmex CS2000i instrument (Siemens; Erlangen, Germany). VWF:RCo was performed by aggregometry on a Helena AggRAM instrument (Helena Laboratories, Beaumont, TX, USA). There was excellent correlation between VWF:Ac results run at two different sites on two different instruments. VWF:Ac had greater precision and sensitivity to low levels of VWF than the VWF:RCo method.

Although there was good correlation between VWF:Ac and VWF:RCo results among healthy controls and patient subjects, VWF:Ac results were undetectable and/or significantly lower than VWF:RCo among patients who had types 2A, 2B, or 2M VWD. Additionally, a higher proportion of patient samples were classified as showing qualitative defects using the VWF:Ac compared with VWF:RCo method.

The authors concluded that the Innovance VWF:Ac method is an acceptable, automated alternative to the VWF:RCo method for assessment of VWF binding to the platelet receptor glycoprotein GPIbα that is sensitive to both quantitative and qualitative defects of VWF. Laboratories and clinicians need to be aware that some patients with VWD have much lower levels of VWF measured by the VWF:Ac assay than by VWF:RCo. The study was published on April 18, 2014, in the International Journal of Laboratory Hematology.

Related Links:

McMaster University 
Diagnostica Stago
Siemens Healthcare



Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gold Member
Hybrid Pipette
SWITCH
Gold Member
Hematology Analyzer
Medonic M32B

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more