Lateral flow assays (LFAs) are popular point-of-care diagnostic tools because they are rapid and easy to use. However, LFAs often lack analytical sensitivity and quantitative output and may be difficult to multiplex, limiting their usefulness in biomarker measurement.
Scientists at SRI International (Menlo Park, CA, USA) designed a quantitative, multiplex LFA with readily available near-infrared (NIR) detection to improve analytical sensitivity. They constructed and optimized a multiplex LFA that simultaneously and accurately measured interleukin (IL)-6 and C- reactive protein (CRP) in 10% human plasma on one test strip.
Commercially available antibodies were conjugated with the fluorescent dye IRDye 800CW (Li-Cor; Lincoln, NE, USA). The investigators used singleplex, optimized NIR-LFAs to measure IL-6 from 0 to 200 pg/mL and developed duplex assays to simultaneously measure IL-6 from 0 to 100 pg/mL (0 to 4.5 pmol/L) and CRP from 50 to 2,500 ng/mL (0.4 to 20 nmol/L) on a single test strip. Assays were tested on 60 different spiked samples and compared to enzyme-linked immunosorbent assay (ELISA) results. The intensity ratios for unknown samples were compared to the calibration curve to determine analyte concentrations and samples were run in quadruplicate.
The choice of an inhibition-style assay rather than a sandwich-style assay avoided the complications due to a potential hook effect at high CRP concentrations. With this approach, free CRP present in the sample inhibited binding of the dye-conjugated antibody to CRP striped on the membrane. As the concentration of CRP in the sample increases, the signal directly decreases. The NIR-LFAs detected IL-6 in a 10% plasma matrix with a limit of detection of 4 pg/mL (182 fmol/L). The duplex NIR-LFAs quantitatively measured IL-6 and CRP concentrations simultaneously. The values strongly correlated to ELISA measurements, with linear regression R2 values of 0.9825 and 0.9711 for IL-6 and CRP, respectively.
The authors concluded that NIR-LFAs exhibit quantitative measurement at pg/mL concentrations owing to a high signal-to-background ratio and robust detection antibody clearance through the test strip. Moreover, NIR-LFAs are able to detect molecules present at vastly different concentrations in multiplex format and compare favorably to ELISAs. LFAs with direct NIR detection may be a valuable tool for biomarker evaluation in the point-of-care setting. The study was published on January 30, 2013, in the journal Clinical Chemistry.
Related Links:
SRI International
Li-Cor
Scientists at SRI International (Menlo Park, CA, USA) designed a quantitative, multiplex LFA with readily available near-infrared (NIR) detection to improve analytical sensitivity. They constructed and optimized a multiplex LFA that simultaneously and accurately measured interleukin (IL)-6 and C- reactive protein (CRP) in 10% human plasma on one test strip.
Commercially available antibodies were conjugated with the fluorescent dye IRDye 800CW (Li-Cor; Lincoln, NE, USA). The investigators used singleplex, optimized NIR-LFAs to measure IL-6 from 0 to 200 pg/mL and developed duplex assays to simultaneously measure IL-6 from 0 to 100 pg/mL (0 to 4.5 pmol/L) and CRP from 50 to 2,500 ng/mL (0.4 to 20 nmol/L) on a single test strip. Assays were tested on 60 different spiked samples and compared to enzyme-linked immunosorbent assay (ELISA) results. The intensity ratios for unknown samples were compared to the calibration curve to determine analyte concentrations and samples were run in quadruplicate.
The choice of an inhibition-style assay rather than a sandwich-style assay avoided the complications due to a potential hook effect at high CRP concentrations. With this approach, free CRP present in the sample inhibited binding of the dye-conjugated antibody to CRP striped on the membrane. As the concentration of CRP in the sample increases, the signal directly decreases. The NIR-LFAs detected IL-6 in a 10% plasma matrix with a limit of detection of 4 pg/mL (182 fmol/L). The duplex NIR-LFAs quantitatively measured IL-6 and CRP concentrations simultaneously. The values strongly correlated to ELISA measurements, with linear regression R2 values of 0.9825 and 0.9711 for IL-6 and CRP, respectively.
The authors concluded that NIR-LFAs exhibit quantitative measurement at pg/mL concentrations owing to a high signal-to-background ratio and robust detection antibody clearance through the test strip. Moreover, NIR-LFAs are able to detect molecules present at vastly different concentrations in multiplex format and compare favorably to ELISAs. LFAs with direct NIR detection may be a valuable tool for biomarker evaluation in the point-of-care setting. The study was published on January 30, 2013, in the journal Clinical Chemistry.
Related Links:
SRI International
Li-Cor
Latest Immunology News
- Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
- Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
- Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions
- Cerebrospinal Fluid Test Predicts Dangerous Side Effect of Cancer Treatment
- New Test Measures Preterm Infant Immunity Using Only Two Drops of Blood
- Simple Blood Test Could Help Choose Better Treatments for Patients with Recurrent Endometrial Cancer
- Novel Analytical Method Tracks Progression of Autoimmune Diseases
- 3D Bioprinted Gastric Cancer Model Uses Patient-Derived Tissue Fragments to Predict Drug Response
- Blood Test for Fungal Infections Could End Invasive Tissue Biopsies
- Cutting-Edge Microscopy Technology Enables Tailored Rheumatology Therapies
- New Discovery in Blood Immune Cells Paves Way for Parkinson's Disease Diagnostic Test
- AI Tool Uses Routine Blood Tests to Predict Immunotherapy Response for Various Cancers
- Blood Test Can Predict How Long Vaccine Immunity Will Last
- Microfluidic Chip-Based Device to Measure Viral Immunity
Channels
Clinical Chemistry
view channel
‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection
Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more
Low-Cost Portable Screening Test to Transform Kidney Disease Detection
Millions of individuals suffer from kidney disease, which often remains undiagnosed until it has reached a critical stage. This silent epidemic not only diminishes the quality of life for those affected... Read more
New Method Uses Pulsed Infrared Light to Find Cancer's 'Fingerprints' In Blood Plasma
Cancer diagnoses have traditionally relied on invasive or time-consuming procedures like tissue biopsies. Now, new research published in ACS Central Science introduces a method that utilizes pulsed infrared... Read moreMolecular Diagnostics
view channel
Blood Biomarker Test Could Detect Genetic Predisposition to Alzheimer’s
New medications for Alzheimer’s disease, the most common form of dementia, are now becoming available. These treatments, known as “amyloid antibodies,” work by promoting the removal of small deposits from... Read more
Novel Autoantibody Against DAGLA Discovered in Cerebellitis
Autoimmune cerebellar ataxias are strongly disabling disorders characterized by an impaired ability to coordinate muscle movement. Cerebellar autoantibodies serve as useful biomarkers to support rapid... Read more
Gene-Based Blood Test Accurately Predicts Tumor Recurrence of Advanced Skin Cancer
Melanoma, an aggressive form of skin cancer, becomes extremely difficult to treat once it spreads to other parts of the body. For patients with metastatic melanoma tumors that cannot be surgically removed... Read moreHematology
view channel
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read more
Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
In the United States, approximately 15% of pregnant individuals are RhD-negative. However, in about 40% of these cases, the fetus is also RhD-negative, making the administration of RhoGAM unnecessary.... Read moreMicrobiology
view channel
Handheld Device Delivers Low-Cost TB Results in Less Than One Hour
Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more
New AI-Based Method Improves Diagnosis of Drug-Resistant Infections
Drug-resistant infections, particularly those caused by deadly bacteria like tuberculosis and staphylococcus, are rapidly emerging as a global health emergency. These infections are more difficult to treat,... Read more
Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours
Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read morePathology
view channel
Novel UV and Machine Learning-Aided Method Detects Microbial Contamination in Cell Cultures
Cell therapy holds great potential in treating diseases such as cancers, inflammatory conditions, and chronic degenerative disorders by manipulating or replacing cells to restore function or combat disease.... Read more
New Error-Corrected Method to Help Detect Cancer from Blood Samples Alone
"Liquid biopsy" technology, which relies on blood tests for early cancer detection and monitoring cancer burden in patients, has the potential to transform cancer care. However, detecting the mutational... Read more
"Metal Detector" Algorithm Hunts Down Vulnerable Tumors
Scientists have developed an algorithm capable of functioning as a "metal detector" to identify vulnerable tumors, marking a significant advancement in personalized cancer treatment. This breakthrough... Read more
Novel Technique Uses ‘Sugar’ Signatures to Identify and Classify Pancreatic Cancer Cell Subtypes
Pancreatic cancer is often asymptomatic in its early stages, making it difficult to detect until it has progressed. Consequently, only 15% of pancreatic cancers are diagnosed early enough to allow for... Read moreTechnology
view channel
Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples
As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more
Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more
Innovative, Label-Free Ratiometric Fluorosensor Enables More Sensitive Viral RNA Detection
Viruses present a major global health risk, as demonstrated by recent pandemics, making early detection and identification essential for preventing new outbreaks. While traditional detection methods are... Read moreIndustry
view channel
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more