Temperature Affects Leukocyte Surface Antigen Expression
|
By LabMedica International staff writers Posted on 14 Apr 2011 |
Flow cytometry analysis of leukocyte surface antigens has been used to characterize infectious and septic processes in patients.
Factors that affect leukocyte immunophenotyping include sampling and processing temperature, the anticoagulant used, and the storage temperature of the blood sample.
Scientists at the University of Oulu, (Oulu, Finland), investigated the possible effects of anticoagulant, sample collection, storage and processing temperature, and sample storage time, on the expression of several leukocyte surface antigens. They collected blood from five male patients, aged 44-68, with severe sepsis requiring intensive care and five healthy staff members (two males and three females, aged 22-62). In this study, the patients and the healthy volunteers were combined into one study population.
Blood was collected into siliconized vacuum tubes containing acid citrate dextrose (ACD) or sodium heparin as an anticoagulant and stored either at 4 °C or at room temperature (RT). Aliquots of the blood samples were incubated with various antibodies at different temperatures and times and analyzed on a FACSCalibur flow cytometer (BD Bioscience; San Jose, CA, USA). The surface antigens of interest were neutrophilic cluster of differentiation (CD)11b and CD64, monocytic CD11b, CD14, CD40, CD64, CD80 and human leukocyte antigen, HLA-DR, and lymphocytic CD69 (separately in CD4+ and CD8+ T cells, B cells, and natural killer cells).
The fluorescence intensities were higher at RT than at 4 °C. During storage the intensities increased at RT, but at 4 °C there were only minor changes. The effects were similar with both anticoagulants studied. The authors concluded that the study shows in a quantitative way that storing the blood samples at RT may have pronounced effects on the intensities of several leukocyte surface antigens, something which is of interest in leukocyte activation studies, such as patients with sepsis. They recommended that flow cytometric analysis of leukocyte surface antigen expressions should be performed using 4 °C temperature throughout the process and within six hours. The study was published online March 15, 2011, in the Journal of Clinical Laboratory Analysis.
Related Links:
University of Oulu
BD Bioscience
Factors that affect leukocyte immunophenotyping include sampling and processing temperature, the anticoagulant used, and the storage temperature of the blood sample.
Scientists at the University of Oulu, (Oulu, Finland), investigated the possible effects of anticoagulant, sample collection, storage and processing temperature, and sample storage time, on the expression of several leukocyte surface antigens. They collected blood from five male patients, aged 44-68, with severe sepsis requiring intensive care and five healthy staff members (two males and three females, aged 22-62). In this study, the patients and the healthy volunteers were combined into one study population.
Blood was collected into siliconized vacuum tubes containing acid citrate dextrose (ACD) or sodium heparin as an anticoagulant and stored either at 4 °C or at room temperature (RT). Aliquots of the blood samples were incubated with various antibodies at different temperatures and times and analyzed on a FACSCalibur flow cytometer (BD Bioscience; San Jose, CA, USA). The surface antigens of interest were neutrophilic cluster of differentiation (CD)11b and CD64, monocytic CD11b, CD14, CD40, CD64, CD80 and human leukocyte antigen, HLA-DR, and lymphocytic CD69 (separately in CD4+ and CD8+ T cells, B cells, and natural killer cells).
The fluorescence intensities were higher at RT than at 4 °C. During storage the intensities increased at RT, but at 4 °C there were only minor changes. The effects were similar with both anticoagulants studied. The authors concluded that the study shows in a quantitative way that storing the blood samples at RT may have pronounced effects on the intensities of several leukocyte surface antigens, something which is of interest in leukocyte activation studies, such as patients with sepsis. They recommended that flow cytometric analysis of leukocyte surface antigen expressions should be performed using 4 °C temperature throughout the process and within six hours. The study was published online March 15, 2011, in the Journal of Clinical Laboratory Analysis.
Related Links:
University of Oulu
BD Bioscience
Latest Immunology News
- Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug
- Whole-Genome Sequencing Approach Identifies Cancer Patients Benefitting From PARP-Inhibitor Treatment
- Ultrasensitive Liquid Biopsy Demonstrates Efficacy in Predicting Immunotherapy Response
- Blood Test Could Identify Colon Cancer Patients to Benefit from NSAIDs
- Blood Test Could Detect Adverse Immunotherapy Effects
- Routine Blood Test Can Predict Who Benefits Most from CAR T-Cell Therapy
- New Test Distinguishes Vaccine-Induced False Positives from Active HIV Infection
- Gene Signature Test Predicts Response to Key Breast Cancer Treatment
- Chip Captures Cancer Cells from Blood to Help Select Right Breast Cancer Treatment
- Blood-Based Liquid Biopsy Model Analyzes Immunotherapy Effectiveness
- Signature Genes Predict T-Cell Expansion in Cancer Immunotherapy
- Molecular Microscope Diagnostic System Assesses Lung Transplant Rejection
- Blood Test Tracks Treatment Resistance in High-Grade Serous Ovarian Cancer
- Luminescent Probe Measures Immune Cell Activity in Real Time
- Blood-Based Immune Cell Signatures Could Guide Treatment Decisions for Critically Ill Patients
- Novel Tool Predicts Most Effective Multiple Sclerosis Medication for Patients
Channels
Clinical Chemistry
view channel
New PSA-Based Prognostic Model Improves Prostate Cancer Risk Assessment
Prostate cancer is the second-leading cause of cancer death among American men, and about one in eight will be diagnosed in their lifetime. Screening relies on blood levels of prostate-specific antigen... Read more
Extracellular Vesicles Linked to Heart Failure Risk in CKD Patients
Chronic kidney disease (CKD) affects more than 1 in 7 Americans and is strongly associated with cardiovascular complications, which account for more than half of deaths among people with CKD.... Read moreMolecular Diagnostics
view channel
Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test
Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more
Blood Test Detects Early-Stage Cancers by Measuring Epigenetic Instability
Early-stage cancers are notoriously difficult to detect because molecular changes are subtle and often missed by existing screening tools. Many liquid biopsies rely on measuring absolute DNA methylation... Read more
“Lab-On-A-Disc” Device Paves Way for More Automated Liquid Biopsies
Extracellular vesicles (EVs) are tiny particles released by cells into the bloodstream that carry molecular information about a cell’s condition, including whether it is cancerous. However, EVs are highly... Read more
Blood Test Identifies Inflammatory Breast Cancer Patients at Increased Risk of Brain Metastasis
Brain metastasis is a frequent and devastating complication in patients with inflammatory breast cancer, an aggressive subtype with limited treatment options. Despite its high incidence, the biological... Read moreHematology
view channel
New Guidelines Aim to Improve AL Amyloidosis Diagnosis
Light chain (AL) amyloidosis is a rare, life-threatening bone marrow disorder in which abnormal amyloid proteins accumulate in organs. Approximately 3,260 people in the United States are diagnosed... Read more
Fast and Easy Test Could Revolutionize Blood Transfusions
Blood transfusions are a cornerstone of modern medicine, yet red blood cells can deteriorate quietly while sitting in cold storage for weeks. Although blood units have a fixed expiration date, cells from... Read more
Automated Hemostasis System Helps Labs of All Sizes Optimize Workflow
High-volume hemostasis sections must sustain rapid turnaround while managing reruns and reflex testing. Manual tube handling and preanalytical checks can strain staff time and increase opportunities for error.... Read more
High-Sensitivity Blood Test Improves Assessment of Clotting Risk in Heart Disease Patients
Blood clotting is essential for preventing bleeding, but even small imbalances can lead to serious conditions such as thrombosis or dangerous hemorrhage. In cardiovascular disease, clinicians often struggle... Read moreMicrobiology
view channel
Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease
Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read moreAI-Powered Platform Enables Rapid Detection of Drug-Resistant C. Auris Pathogens
Infections caused by the pathogenic yeast Candida auris pose a significant threat to hospitalized patients, particularly those with weakened immune systems or those who have invasive medical devices.... Read morePathology
view channel
Engineered Yeast Cells Enable Rapid Testing of Cancer Immunotherapy
Developing new cancer immunotherapies is a slow, costly, and high-risk process, particularly for CAR T cell treatments that must precisely recognize cancer-specific antigens. Small differences in tumor... Read more
First-Of-Its-Kind Test Identifies Autism Risk at Birth
Autism spectrum disorder is treatable, and extensive research shows that early intervention can significantly improve cognitive, social, and behavioral outcomes. Yet in the United States, the average age... Read moreTechnology
view channel
Robotic Technology Unveiled for Automated Diagnostic Blood Draws
Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more
ADLM Launches First-of-Its-Kind Data Science Program for Laboratory Medicine Professionals
Clinical laboratories generate billions of test results each year, creating a treasure trove of data with the potential to support more personalized testing, improve operational efficiency, and enhance patient care.... Read moreAptamer Biosensor Technology to Transform Virus Detection
Rapid and reliable virus detection is essential for controlling outbreaks, from seasonal influenza to global pandemics such as COVID-19. Conventional diagnostic methods, including cell culture, antigen... Read more
AI Models Could Predict Pre-Eclampsia and Anemia Earlier Using Routine Blood Tests
Pre-eclampsia and anemia are major contributors to maternal and child mortality worldwide, together accounting for more than half a million deaths each year and leaving millions with long-term health complications.... Read moreIndustry
view channelNew Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing
Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more
AI-Powered Cervical Cancer Test Set for Major Rollout in Latin America
Noul Co., a Korean company specializing in AI-based blood and cancer diagnostics, announced it will supply its intelligence (AI)-based miLab CER cervical cancer diagnostic solution to Mexico under a multi‑year... Read more
Diasorin and Fisher Scientific Enter into US Distribution Agreement for Molecular POC Platform
Diasorin (Saluggia, Italy) has entered into an exclusive distribution agreement with Fisher Scientific, part of Thermo Fisher Scientific (Waltham, MA, USA), for the LIAISON NES molecular point-of-care... Read more