We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Novel SARS CoV-2 Saliva Collection Devices Improve Lab Efficiency and PCR Test Performance

By LabMedica International staff writers
Posted on 28 Jan 2021
Print article
Image: GenTegra GTR-STM and direct-into-PCR GenTegra GTR-STMdk saliva sample collection tubes (Photo courtesy of GenTegra, LLC)
Image: GenTegra GTR-STM and direct-into-PCR GenTegra GTR-STMdk saliva sample collection tubes (Photo courtesy of GenTegra, LLC)
Two new saliva SARS-CoV-2 sample collection products are expected to facilitate the expansion of COVID-19 testing, address testing challenges, and improve lab efficiency and PCR test performance.

The GenTegra GTR-STM and direct-into-PCR GenTegra GTR-STMdk saliva sample collection tubes from GenTegra, LLC (Pleasanton, CA, USA) are the only devices that eliminate dilution of virus levels in saliva samples, while providing a safe and convenient means to transport saliva samples at ambient conditions. Direct-into-PCR, GTR-STMdk eliminates the need for expensive and time consuming RNA extraction, improving the turnaround time for reporting test results. The two novel products are available to CLIA certified laboratories and IVD assay kit manufacturers pursuant to regulatory approvals in their respective US FDA Emergency User Authorization (EUA) protocols.

The dried transport media formulation in both of these devices incorporates the company’s Active Chemical Protection (ACP) technology to provide substantial improvements in SARS-CoV-2 viral RNA stability, and RT-PCR process efficiency for COVID-19 saliva testing. The company’s ACP technology incorporates a proprietary combination of small molecule inhibitors, antioxidants, metal chelators, and anti-microbials to provide total protection for SARS-CoV-2 virus and viral RNA at ambient temperatures. Proprietary ACP chemistry reduces saliva viscosity, inactivates contaminating RNases, and bacteria, and facilitates sterilization of samples at 95C making the sample safe for lab personnel and testing. ACP chemistry is guanidinium free making it compatible with lab automation and self-sterilizing PCR instrumentation.

“By creating a dry transport media formulation of our proven ACP technology, we have eliminated many of the risks and error prone steps involved with current COVID-19 saliva collection products,” said GenTegra President Bob Barrett. “Most importantly, eliminating the addition of a liquid sample stabilizer may improve low copy number detection, and may address some of the concerns of potential false negatives due to sample dilution. This may be especially true when testing asymptomatic populations where viral load in saliva may be low and when multiple samples are pooled for greater testing efficiency.”

Related Links:
GenTegra, LLC

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
SARS-CoV-2 Reactive & Non-Reactive Controls
Qnostics SARS-CoV-2 Typing

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more