LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Novel Digital Morphology Analyzer Performance Evaluated

By LabMedica International staff writers
Posted on 01 Dec 2022
Image: The CellaVision DC-1 is a stand-alone hematology analyzer that performs blood cell differentials. It offers a suitable solution for laboratories with small workloads (Photo courtesy of Sysmex)
Image: The CellaVision DC-1 is a stand-alone hematology analyzer that performs blood cell differentials. It offers a suitable solution for laboratories with small workloads (Photo courtesy of Sysmex)

Microscopic examination of peripheral blood smear (PBS) is essential in clinical hematology laboratories. Manual counting is, however, inefficient because the process is technically demanding and labor-intensive resulting in long turnaround time (TAT), and the results may be subjective with inter-observer variation.

Digital morphology (DM) analyzers can provide analysis of cell morphology (pre-classification) with reduced TAT and inter-observer variation. In a recent study, DM analyzers showed advantages over manual counting in laboratory efficiency including shortened TAT. DM analyzers can be used mainly in large-volume laboratories, and they are too large and expensive to be used in small to medium-volume laboratories.

Medical Laboratory Scientists at the Konkuk University School of Medicine (Seoul, Korea) obtained PBS slides from healthy individuals, spanning normal white blood cell (WBC) range including mild leukopenia (2.0–4.0 × 109/L) and mild leukocytosis (10.0–15.0 × 109/L). WBC counts in these samples were 3.90 × 109/L, 5.19 × 109/L, 6.72 × 109/L, 8.72 × 109/L, and 10.78 × 109/L, respectively. Venous whole blood samples were collected and were used for complete blood counts in XN-9000 (Sysmex, Kobe, Japan), and PBS slides were made and reviewed for WBC differentials.

The Sysmex CellaVision DC-1 (DC1) is a newly launched digital morphology analyzer that was developed mainly for small to medium-volume laboratories. The scientists evaluated the precision, qualitative performance, comparison of cell counts between DC-1 and manual counting, and turnaround time (TAT) of DC-1. Pre-classification on DC-1 included total 18 cell classes (12 WBC classes and six non-WBC classes). The 12 WBC classes include blasts, promyelocytes, myelocytes, metamyelocytes, band neutrophils, segmented neutrophils, lymphocytes, monocytes, eosinophils, basophils, variant lymphocytes, and plasma cells. The six non-WBC classes include nucleated RBCs (nRBCs), smudge cells, artifact, giant platelet, platelet aggregation, and unidentified cells.

The investigators reported that DC-1 showed excellent precision (%CV, 0.0%–3.5%), high specificity (98.9%–100.0%), and high negative predictive value (98.4%–100.0%) in 18 cell classes (12 WBC classes and six non-WBC classes). However, DC-1 showed 0% of positive predictive value in seven cell classes (metamyelocytes, myelocytes, promyelocytes, blasts, plasma cells, nucleated red blood cells, and unidentified). The largest absolute mean differences (%) of DC-1 versus manual counting was 2.74. Total TAT (min:s) was comparable between DC-1 (8:55) and manual counting (8:55).

The authors concluded that their study showed that DC-1 has a reliable analytical performance in all cell classes, and it can be used in small-to medium-volume laboratories for providing assist of manpower in daily practice of PBS review. However, DC-1 may make unnecessary workload for cell verification in some cell classes. The study was published on October 31, 2022 in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Konkuk University School of Medicine
Sysmex

Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Homocysteine Quality Control
Liquichek Homocysteine Control
Pipette
Accumax Smart Series

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more