We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Improved ALS Blood Test Requires Less Stringent Storage and Work Conditions

By LabMedica International staff writers
Posted on 05 Sep 2022
Image: Artist’s conception of amyotrophic lateral sclerosis (ALS) (Photo courtesy of www.123rf.com)
Image: Artist’s conception of amyotrophic lateral sclerosis (ALS) (Photo courtesy of www.123rf.com)

Improvements to the method for isolating extracellular vesicles from the blood of amyotrophic lateral sclerosis (ALS) patients have yielded a more robust test for detection of the disorder that may be used under routine laboratory conditions.

ALS is a neurodegenerative disease characterized by the selective and progressive death of upper and lower motor neurons. This leads to progressive muscle weakness, and death of the patient usually occurs within two to five years after the onset of symptoms. An EV-based blood test for ALS was described by investigators at Brain Chemistry Labs (Jackson, WY, USA) in 2020. However, the precise protocols for shipping and storage of blood samples, which were maintained at -80 degrees Celsius, meant that most doctors’ offices and routine clinical laboratories were unable to utilize the test.

Extracellular vesicles (EVs) are small, non-replicating particles released from cells that contain material from the source cell and are surrounded by lipid bilayer membranes. Molecules within EVs are considered to be promising material for prospective biomarkers because of the lipid bilayer membrane that protects them from degradation. Among these molecules are short non-coding RNA strands or micro RNA (miRNA), which function to regulate post-transcriptional gene expression. In an earlier study the investigators identified eight miRNAs extracted from EVs that were diagnostic of early-stage ALS.

In the current study, the investigators tested the hypotheses that miRNA extracted from extracellular vesicles using immunoaffinity purification techniques would be robust and repeatable across investigators, laboratories and in a broad ALS population. The immunoaffinity purification protocol was based on the L1 cell adhesion molecule (L1CAM), which is a cell surface glycoprotein having a 1253 amino acid protein sequence. The extracellular portion is formed of six immunoglobulin domains followed by five fibronectin type III domains which are connected to a small intracellular domain by a transmembrane helix.

In this study, patient blood plasma samples obtained from the U.S. National ALS Biorepository were compared with plasma from non-ALS controls. Extracellular vesicles were extracted and isolated using L1CAM immunoaffinity purification. Total RNA was extracted, and miRNA quantified using qPCR following careful quality control measures.

One hundred blinded, blood plasma samples were analyzed. A group of 35 men and 15 women with ALS were compared with controls consisting of 30 men and 20 women. None of the ALS patient cohort reported family members with ALS, suggesting sporadic ALS. Five of the eight biomarkers previously published were found to discriminate ALS patient samples from control samples. The consistency of the results across different ALS patient populations under less stringent plasma collection/storage parameters provided evidence of the value of miRNA derived from L1CAM-enriched EVs for ALS diagnosis.

“We were surprised that the microRNA test worked for samples collected from a variety of investigators under differing conditions,” said first author Dr. Sandra Banack, senior scientist at Brain Chemistry Labs. Her colleagues, Dr. Rachael Dunlop and Dr. Paul Cox added, “We expected samples would need to be stringently collected and stored. Apparently, the extracellular vesicles shed into the blood protect their genetic cargo against differing environmental conditions.”

The report was published in the August 29, 2022, online edition of the Journal of the Neurological Sciences.

Related Links:
Brain Chemistry Labs 

Gold Member
Hematology Analyzer
Medonic M32B
POC Helicobacter Pylori Test Kit
Hepy Urease Test
8-Channel Pipette
SAPPHIRE 20–300 µL
Homocysteine Quality Control
Liquichek Homocysteine Control

Channels

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more