Long-Term Storage Stability of Corticotropin Investigated
|
By LabMedica International staff writers Posted on 20 Dec 2021 |

Image: The ARCHITECT i2000SR automated immunoassay instrument system (Photo courtesy of Abbott Laboratories)
Corticotropin (adrenocorticotropic hormone, ACTH) is a 39-residue polypeptide tropic hormone secreted by the anterior pituitary gland following hypothalamic corticotropin-releasing hormone release. Corticotropin is notorious for its instability.
Cortisol regulates ACTH release via a negative feedback loop. Measurements of plasma ACTH are crucial for differential diagnosis of endocrine disorders including Cushing’s syndrome and adrenal insufficiency but can be complicated by both preanalytical and analytical factors.
Clinical Biochemists at Amsterdam University (Amsterdam, The Netherlands) and their colleagues investigated the long-term storage stability of corticotropin in ethylenediaminetetraacetic acid containing plasma. Plasma specimens were obtained from 20 healthy American subjects that were either neat or spiked with ACTH (22–1,866 pg/ml). Plasma specimens were also obtained from Dutch patients visiting the Amsterdam University Medical Centers (UMC, Amsterdam, The Netherlands), between 2012 and 2013 for various indications.
Individual specimens were assayed on the day of processing (month 0) and five times (at 1, 3, 9, 12, and 18 months) following storage at both −20 °C and −70 °C in five replicates each. Specimens were thawed once on the laboratory countertop at room temperature, mixed by gentle inversion and centrifuged at 3,000×g for 5 minutes Afterwards they were kept at room temperature and quickly analyzed. ACTH results were generated on the ARCHITECT i2000SR automated immunoassay instrument system (Abbott Laboratories, Abbott Park, IL, USA). The team also used a chemiluminescence immunoassay (CLIA) that uses two monoclonal antibodies of which the Liaison capture antibody that is coated to magnetic particles and the detection antibody is linked to an isoluminol derivative (Diasorin, Salugia, Italy).
The team reported that storing human plasma specimens for up to one and a half years at −20 °C or −70 °C had limited influence on the ACTH levels in these specimens measured by the ARCHITECT ACTH assay. In both neat and spiked specimens at the two storage conditions, ACTH levels remained relatively stable over time with only minimal changes in ACTH levels (<11%). Storing specimens for up to four or six years did significantly reduce detectable ACTH levels in native patient plasma specimens. After four years of storage at −20 °C, ACTH levels were 74.8%, whereas after six years of storage ACTH levels were only 46.2% of the original ACTH levels measured using the Liaison immunoassay.
The authors concluded that corticotropin levels are stable in plasma when stored at −20 °C for one and a half years using the Abbott assay, but with longer storage time a significant reduction in corticotropin levels can be expected. Once specimens are stored for future corticotropin measurements, one should consider storage time, storage temperature and assay differences. The study was originally published on October 13, 2021 in the journal Clinical Chemistry and Laboratory Medicine.
Related Links:
Amsterdam University
Amsterdam University Medical Centers
Abbott Laboratories
Diasorin
Cortisol regulates ACTH release via a negative feedback loop. Measurements of plasma ACTH are crucial for differential diagnosis of endocrine disorders including Cushing’s syndrome and adrenal insufficiency but can be complicated by both preanalytical and analytical factors.
Clinical Biochemists at Amsterdam University (Amsterdam, The Netherlands) and their colleagues investigated the long-term storage stability of corticotropin in ethylenediaminetetraacetic acid containing plasma. Plasma specimens were obtained from 20 healthy American subjects that were either neat or spiked with ACTH (22–1,866 pg/ml). Plasma specimens were also obtained from Dutch patients visiting the Amsterdam University Medical Centers (UMC, Amsterdam, The Netherlands), between 2012 and 2013 for various indications.
Individual specimens were assayed on the day of processing (month 0) and five times (at 1, 3, 9, 12, and 18 months) following storage at both −20 °C and −70 °C in five replicates each. Specimens were thawed once on the laboratory countertop at room temperature, mixed by gentle inversion and centrifuged at 3,000×g for 5 minutes Afterwards they were kept at room temperature and quickly analyzed. ACTH results were generated on the ARCHITECT i2000SR automated immunoassay instrument system (Abbott Laboratories, Abbott Park, IL, USA). The team also used a chemiluminescence immunoassay (CLIA) that uses two monoclonal antibodies of which the Liaison capture antibody that is coated to magnetic particles and the detection antibody is linked to an isoluminol derivative (Diasorin, Salugia, Italy).
The team reported that storing human plasma specimens for up to one and a half years at −20 °C or −70 °C had limited influence on the ACTH levels in these specimens measured by the ARCHITECT ACTH assay. In both neat and spiked specimens at the two storage conditions, ACTH levels remained relatively stable over time with only minimal changes in ACTH levels (<11%). Storing specimens for up to four or six years did significantly reduce detectable ACTH levels in native patient plasma specimens. After four years of storage at −20 °C, ACTH levels were 74.8%, whereas after six years of storage ACTH levels were only 46.2% of the original ACTH levels measured using the Liaison immunoassay.
The authors concluded that corticotropin levels are stable in plasma when stored at −20 °C for one and a half years using the Abbott assay, but with longer storage time a significant reduction in corticotropin levels can be expected. Once specimens are stored for future corticotropin measurements, one should consider storage time, storage temperature and assay differences. The study was originally published on October 13, 2021 in the journal Clinical Chemistry and Laboratory Medicine.
Related Links:
Amsterdam University
Amsterdam University Medical Centers
Abbott Laboratories
Diasorin
Latest Immunology News
- Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug
- Whole-Genome Sequencing Approach Identifies Cancer Patients Benefitting From PARP-Inhibitor Treatment
- Ultrasensitive Liquid Biopsy Demonstrates Efficacy in Predicting Immunotherapy Response
- Blood Test Could Identify Colon Cancer Patients to Benefit from NSAIDs
- Blood Test Could Detect Adverse Immunotherapy Effects
- Routine Blood Test Can Predict Who Benefits Most from CAR T-Cell Therapy
- New Test Distinguishes Vaccine-Induced False Positives from Active HIV Infection
- Gene Signature Test Predicts Response to Key Breast Cancer Treatment
- Chip Captures Cancer Cells from Blood to Help Select Right Breast Cancer Treatment
- Blood-Based Liquid Biopsy Model Analyzes Immunotherapy Effectiveness
- Signature Genes Predict T-Cell Expansion in Cancer Immunotherapy
- Molecular Microscope Diagnostic System Assesses Lung Transplant Rejection
- Blood Test Tracks Treatment Resistance in High-Grade Serous Ovarian Cancer
- Luminescent Probe Measures Immune Cell Activity in Real Time
- Blood-Based Immune Cell Signatures Could Guide Treatment Decisions for Critically Ill Patients
- Novel Tool Predicts Most Effective Multiple Sclerosis Medication for Patients
Channels
Molecular Diagnostics
view channel
Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test
Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more
Blood Test Detects Early-Stage Cancers by Measuring Epigenetic Instability
Early-stage cancers are notoriously difficult to detect because molecular changes are subtle and often missed by existing screening tools. Many liquid biopsies rely on measuring absolute DNA methylation... Read more
“Lab-On-A-Disc” Device Paves Way for More Automated Liquid Biopsies
Extracellular vesicles (EVs) are tiny particles released by cells into the bloodstream that carry molecular information about a cell’s condition, including whether it is cancerous. However, EVs are highly... Read more
Blood Test Identifies Inflammatory Breast Cancer Patients at Increased Risk of Brain Metastasis
Brain metastasis is a frequent and devastating complication in patients with inflammatory breast cancer, an aggressive subtype with limited treatment options. Despite its high incidence, the biological... Read moreHematology
view channel
New Guidelines Aim to Improve AL Amyloidosis Diagnosis
Light chain (AL) amyloidosis is a rare, life-threatening bone marrow disorder in which abnormal amyloid proteins accumulate in organs. Approximately 3,260 people in the United States are diagnosed... Read more
Fast and Easy Test Could Revolutionize Blood Transfusions
Blood transfusions are a cornerstone of modern medicine, yet red blood cells can deteriorate quietly while sitting in cold storage for weeks. Although blood units have a fixed expiration date, cells from... Read more
Automated Hemostasis System Helps Labs of All Sizes Optimize Workflow
High-volume hemostasis sections must sustain rapid turnaround while managing reruns and reflex testing. Manual tube handling and preanalytical checks can strain staff time and increase opportunities for error.... Read more
High-Sensitivity Blood Test Improves Assessment of Clotting Risk in Heart Disease Patients
Blood clotting is essential for preventing bleeding, but even small imbalances can lead to serious conditions such as thrombosis or dangerous hemorrhage. In cardiovascular disease, clinicians often struggle... Read moreImmunology
view channelBlood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug
Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more
Whole-Genome Sequencing Approach Identifies Cancer Patients Benefitting From PARP-Inhibitor Treatment
Targeted cancer therapies such as PARP inhibitors can be highly effective, but only for patients whose tumors carry specific DNA repair defects. Identifying these patients accurately remains challenging,... Read more
Ultrasensitive Liquid Biopsy Demonstrates Efficacy in Predicting Immunotherapy Response
Immunotherapy has transformed cancer treatment, but only a small proportion of patients experience lasting benefit, with response rates often remaining between 10% and 20%. Clinicians currently lack reliable... Read moreMicrobiology
view channel
Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease
Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read moreAI-Powered Platform Enables Rapid Detection of Drug-Resistant C. Auris Pathogens
Infections caused by the pathogenic yeast Candida auris pose a significant threat to hospitalized patients, particularly those with weakened immune systems or those who have invasive medical devices.... Read morePathology
view channel
Engineered Yeast Cells Enable Rapid Testing of Cancer Immunotherapy
Developing new cancer immunotherapies is a slow, costly, and high-risk process, particularly for CAR T cell treatments that must precisely recognize cancer-specific antigens. Small differences in tumor... Read more
First-Of-Its-Kind Test Identifies Autism Risk at Birth
Autism spectrum disorder is treatable, and extensive research shows that early intervention can significantly improve cognitive, social, and behavioral outcomes. Yet in the United States, the average age... Read moreTechnology
view channel
Robotic Technology Unveiled for Automated Diagnostic Blood Draws
Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more
ADLM Launches First-of-Its-Kind Data Science Program for Laboratory Medicine Professionals
Clinical laboratories generate billions of test results each year, creating a treasure trove of data with the potential to support more personalized testing, improve operational efficiency, and enhance patient care.... Read moreAptamer Biosensor Technology to Transform Virus Detection
Rapid and reliable virus detection is essential for controlling outbreaks, from seasonal influenza to global pandemics such as COVID-19. Conventional diagnostic methods, including cell culture, antigen... Read more
AI Models Could Predict Pre-Eclampsia and Anemia Earlier Using Routine Blood Tests
Pre-eclampsia and anemia are major contributors to maternal and child mortality worldwide, together accounting for more than half a million deaths each year and leaving millions with long-term health complications.... Read moreIndustry
view channelNew Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing
Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more
AI-Powered Cervical Cancer Test Set for Major Rollout in Latin America
Noul Co., a Korean company specializing in AI-based blood and cancer diagnostics, announced it will supply its intelligence (AI)-based miLab CER cervical cancer diagnostic solution to Mexico under a multi‑year... Read more
Diasorin and Fisher Scientific Enter into US Distribution Agreement for Molecular POC Platform
Diasorin (Saluggia, Italy) has entered into an exclusive distribution agreement with Fisher Scientific, part of Thermo Fisher Scientific (Waltham, MA, USA), for the LIAISON NES molecular point-of-care... Read more







