LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Automated Immunoassay Systems Evaluated for KL‐6 Antigen Quantification

By LabMedica International staff writers
Posted on 20 Nov 2019
Image: The HISCL-5000 is a fully automated immunoassay analyzer with a throughput of 200 tests per hour. The incubation time for each parameter is 17 minute and allows each laboratory to achieve maximum efficiency and productivity (Photo courtesy of Sysmex Corporation).
Image: The HISCL-5000 is a fully automated immunoassay analyzer with a throughput of 200 tests per hour. The incubation time for each parameter is 17 minute and allows each laboratory to achieve maximum efficiency and productivity (Photo courtesy of Sysmex Corporation).
Interstitial lung disease (ILD) is a group of diseases characterized by various forms of pulmonary interstitial inflammation and fibrosis, which are usually chronic, progressive, and fatal, causing death 2‐5 years after diagnosis in most patients.

The sputum saccharide chain antigen, Krebs von den Lungen‐6 (KL‐6), is a serum biomarker of lung injury. Since the most important feature of ILD is repeated damage or repair of type II alveolar epithelial cells, KL‐6 is secreted by these cells, and therefore KL‐6 is considered the most accurate biomarker in the diagnosis of ILD.

Immunologists at The First Affiliated Hospital of Guangzhou Medical University (Guangzhou, China) and their associates collected serum samples from 145 individuals between May 2018 and October 2018. Of 145 subjects, 25 had lung cancer, 56 had ILD, 35 had other respiratory diseases, and 29 were healthy individuals (control group) who underwent regular health checkup. There were 83 (57.24%) men and 62 women with a median age distribution of 56 years (interquartile range: 46-67).

The scientists evaluated the basic performance of KL‐6 assays using the HISCL‐5000 analyzer (Sysmex Corporation, Kobe, Japan), a fully automated immunochemistry analyzer that employs a chemiluminescence enzyme immunoassay (CLEIA) methodology with a two‐step sandwich immunoassay. The results were compared with those from the LUMIPULSE G1200 analyzer (Fujirebio Europe N.V., Zwijnaarde, Belgium). The analytical measurement ranges of HISCL‐5000 and LUMIPULSE G1200 were 10‐6,000 U/mL and 50‐10,000 U/mL, respectively.

The scientists reported that with a cutoff level of 500 U/mL, comparing the two systems, the agreement, sensitivity, specificity, and kappa value were 99.2%, 100%, 98.63%, and 0.984, respectively. Spearman's correlation and intraclass correlation coefficient (ICC) showed that there was a strong correlation between serum KL‐6 levels measured by the two systems. The clinical diagnosis agreement rate in both systems was >80%. The KL‐6 level in the ILD group was significantly higher than that in the non‐ILD groups, and the KL‐6 level (1,558, 726‐2,772.5) in the ILD group detected by HISCL‐5000 was significantly higher than that in the lung cancer group (339, 207‐424), other respiratory disease group (249, 194‐366), and control group (198, 131.5‐297).

The authors concluded that the HISCL‐5000 CLEIA system has a high diagnostic efficiency. The method can be applied to the quantitative detection of serum KL‐6 in patients with respiratory diseases. Compared with those in other respiratory diseases, the serum KL‐6 level in patients with ILD is significantly increased, suggesting that clinicians can use KL‐6 in the auxiliary diagnosis of ILD. The study was published on November 6, 2019 in the Journal of Clinical Laboratory Analysis.

Related Links:
The First Affiliated Hospital of Guangzhou Medical University
Sysmex Corporation
Fujirebio Europe N.V.


Gold Member
Respiratory Syncytial Virus Test
OSOM® RSV Test
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Rapid Molecular Testing Device
FlashDetect Flash10
Gram-Negative Blood Culture Assay
LIAISON PLEX Gram-Negative Blood Culture Assay

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more