C-Reactive Protein Point-Of-Care Test Evaluated
By LabMedica International staff writers Posted on 27 Aug 2019 |

Image: The cobas b 101 POC system; an in vitro diagnostic (IVD) test system offering C-reactive protein, HbA1c and a complete lipid profile (CHOL, HDL, LDL, TG) on one device at the point of care (Photo courtesy of Roche Diagnostics).
C-reactive protein (CRP) is a key mediator of the acute-phase response, with blood levels of CRP increasing rapidly after an inflammatory stimulus. Therefore, changes in serum levels of CRP are a clinically useful marker of infection, inflammation, and tissue injury.
CRP testing in the primary setting as in point-of-care (POC) can help reduce diagnostic uncertainty by differentiating between bacterial and viral infections and has been shown to be cost-effective for reducing inappropriate antibiotic prescriptions. However, despite the availability of POC devices, POC CRP testing has not yet been widely adopted in primary care clinics.
Clinical laboratory scientists at the Catharina Hospital and Technical University Eindhoven (Eindhoven, The Netherland) and their colleagues evaluated a POC CPR test at three sites and one reference laboratory. Within-run (repeatability), within-laboratory (intermediate precision), and between-laboratory precision (reproducibility) were assessed. Method comparison and matrix/lot-to-lot comparison studies were conducted using prospectively collected blood samples from 217 adults (apparently healthy or with clinically relevant conditions).
The investigators compared the analytical performance of the cobas b 101 POC system, which provides glycated hemoglobin (HbA1c) and lipid panel tests (measurement of cholesterol, triglyceride, and high-density lipoprotein; calculation of low-density lipoprotein) for managing diabetes and dyslipidemia at point-of-need. This method was compared with a reference test: CRPNX reagent on a Roche cobas c 501 module.
The scientists reported that clinically relevant CRP concentrations measured with the CRP Test showed good agreement with those measured by CRPNX reagent. Coefficients of variation (CV) for repeatability and intermediate precision ranged from 1.7%–4.0% and 1.9%–4.5%, respectively, for human serum pools containing CRP 4.7–350.7 mg/L; repeatability in clinical samples ranged from 1.6%–5.9% (3.3–360.3 mg/L). CVs for reproducibility ranged from 2.5%–4.0% (4.7–344.3 mg/L). CRP concentrations were comparable for capillary whole blood, serum, Li-heparin whole blood/plasma, K2 and K3 EDTA whole blood/plasma. The overall mean usability score was 4.18/5 and the error rate across 9,378 tests was 1.00%.
The authors concluded that their findings indicate that healthcare professionals can obtain precise and reproducible CRP values with the cobas POC CRP Test that show very good correlation with laboratory measurements. Importantly, operators considered the system convenient for use in the POC environment. The study was published in the September 2019 issue of the journal Clinical Biochemistry.
Related Links:
Catharina Hospital and Technical University Eindhoven
CRP testing in the primary setting as in point-of-care (POC) can help reduce diagnostic uncertainty by differentiating between bacterial and viral infections and has been shown to be cost-effective for reducing inappropriate antibiotic prescriptions. However, despite the availability of POC devices, POC CRP testing has not yet been widely adopted in primary care clinics.
Clinical laboratory scientists at the Catharina Hospital and Technical University Eindhoven (Eindhoven, The Netherland) and their colleagues evaluated a POC CPR test at three sites and one reference laboratory. Within-run (repeatability), within-laboratory (intermediate precision), and between-laboratory precision (reproducibility) were assessed. Method comparison and matrix/lot-to-lot comparison studies were conducted using prospectively collected blood samples from 217 adults (apparently healthy or with clinically relevant conditions).
The investigators compared the analytical performance of the cobas b 101 POC system, which provides glycated hemoglobin (HbA1c) and lipid panel tests (measurement of cholesterol, triglyceride, and high-density lipoprotein; calculation of low-density lipoprotein) for managing diabetes and dyslipidemia at point-of-need. This method was compared with a reference test: CRPNX reagent on a Roche cobas c 501 module.
The scientists reported that clinically relevant CRP concentrations measured with the CRP Test showed good agreement with those measured by CRPNX reagent. Coefficients of variation (CV) for repeatability and intermediate precision ranged from 1.7%–4.0% and 1.9%–4.5%, respectively, for human serum pools containing CRP 4.7–350.7 mg/L; repeatability in clinical samples ranged from 1.6%–5.9% (3.3–360.3 mg/L). CVs for reproducibility ranged from 2.5%–4.0% (4.7–344.3 mg/L). CRP concentrations were comparable for capillary whole blood, serum, Li-heparin whole blood/plasma, K2 and K3 EDTA whole blood/plasma. The overall mean usability score was 4.18/5 and the error rate across 9,378 tests was 1.00%.
The authors concluded that their findings indicate that healthcare professionals can obtain precise and reproducible CRP values with the cobas POC CRP Test that show very good correlation with laboratory measurements. Importantly, operators considered the system convenient for use in the POC environment. The study was published in the September 2019 issue of the journal Clinical Biochemistry.
Related Links:
Catharina Hospital and Technical University Eindhoven
Latest Clinical Chem. News
- Carbon Nanotubes Help Build Highly Accurate Sensors for Continuous Health Monitoring
- Paper-Based Device Boosts HIV Test Accuracy from Dried Blood Samples
- AI-Powered Raman Spectroscopy Method Enables Rapid Drug Detection in Blood
- Novel LC-MS/MS Assay Detects Low Creatinine in Sweat and Saliva
- Biosensing Technology Breakthrough Paves Way for New Methods of Early Disease Detection
- New Saliva Test Rapidly Identifies Paracetamol Overdose
- POC Saliva Testing Device Predicts Heart Failure in 15 Minutes
- Screening Tool Detects Multiple Health Conditions from Single Blood Drop
- Integrated Chemistry and Immunoassay Analyzer with Extensive Assay Menu Offers Flexibility, Scalability and Data Commutability
- Rapid Drug Test to Improve Treatment for Patients Presenting to Hospital
- AI Model Detects Cancer at Lightning Speed through Sugar Analyses
- First-Ever Blood-Powered Chip Offers Real-Time Health Monitoring
- New ADLM Guidance Provides Expert Recommendations on Clinical Testing For Respiratory Viral Infections
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
Channels
Molecular Diagnostics
view channel
RNA-Based Blood Test Detects Preeclampsia Risk Months Before Symptoms
Preeclampsia remains a major cause of maternal morbidity and mortality, as well as preterm births. Despite current guidelines that aim to identify pregnant women at increased risk of preeclampsia using... Read more
First Of Its Kind Test Uses microRNAs to Predict Toxicity from Cancer Therapy
Many men with early-stage prostate cancer receive stereotactic body radiotherapy (SBRT), a highly precise form of radiation treatment that is completed in just five sessions. Compared to traditional radiation,... Read more
Novel Cell-Based Assay Provides Sensitive and Specific Autoantibody Detection in Demyelination
Anti-myelin-associated glycoprotein (MAG) antibodies serve as markers for an autoimmune demyelinating disorder that affects the peripheral nervous system, leading to sensory impairment. Anti-MAG-IgM antibodies... Read moreHematology
view channel
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read more
Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
In the United States, approximately 15% of pregnant individuals are RhD-negative. However, in about 40% of these cases, the fetus is also RhD-negative, making the administration of RhoGAM unnecessary.... Read moreImmunology
view channel
Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more
Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
Chimeric antigen receptor (CAR) T-cell therapy has emerged as one of the most promising recent developments in the treatment of blood cancers. However, over half of non-Hodgkin lymphoma (NHL) patients... Read moreMicrobiology
view channel
Handheld Device Deliver Low-Cost TB Results in Less Than One Hour
Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more
New AI-Based Method Improves Diagnosis of Drug-Resistant Infections
Drug-resistant infections, particularly those caused by deadly bacteria like tuberculosis and staphylococcus, are rapidly emerging as a global health emergency. These infections are more difficult to treat,... Read more
Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours
Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read morePathology
view channel
Advanced Imaging Reveals Mechanisms Causing Autoimmune Disease
Myasthenia gravis, an autoimmune disease, leads to muscle weakness that can affect a range of muscles, including those needed for basic actions like blinking, smiling, or moving. Researchers have long... Read more
AI Model Effectively Predicts Patient Outcomes in Common Lung Cancer Type
Lung adenocarcinoma, the most common form of non-small cell lung cancer (NSCLC), typically adopts one of six distinct growth patterns, often combining multiple patterns within a single tumor.... Read moreTechnology
view channel
Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more
Innovative, Label-Free Ratiometric Fluorosensor Enables More Sensitive Viral RNA Detection
Viruses present a major global health risk, as demonstrated by recent pandemics, making early detection and identification essential for preventing new outbreaks. While traditional detection methods are... Read moreIndustry
view channel
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more