Lower HbA1c Levels Seen in Diabetic Liver Disease Patients
By LabMedica International staff writers Posted on 23 May 2019 |

Image: The TOSOH G8 ion exchange high performance liquid chromatography analyzer (Photo courtesy of Tosoh Bioscience).
Diabetes is a leading cause of liver disease, with cirrhosis responsible for a considerable number of deaths in people with diabetes in the USA. The association is mediated by multiple mechanisms including dyslipidemia and altered hepatic fatty acid processing.
Glycated hemoglobin or HbA1c is now widely used for this purpose in primary care, resulting in a doubling of the number of HbA1c assessments requested, and a corresponding decrease in glucose measurement. Since 2014, the use of HbA1c testing has been included in the American Diabetes Association guidelines for the diagnosis of diabetes in hospital.
Scientists at the Queen Elizabeth Hospital (Birmingham, UK) and their colleagues collected HbA1c and random plasma glucose data for 125 people with diabetes without liver disease and for 29 people awaiting liver transplant with diabetes and cirrhosis. Cirrhosis was caused by non‐alcoholic fatty liver disease, hepatitis C, alcoholic liver disease, hereditary hemochromatosis, polycystic liver/kidneys, cryptogenic/non‐cirrhotic portal hypertension and α‐1‐antitrypsin‐related disease.
The team measured biochemical variables on the Roche c8000 analyzers and full blood count on Beckman DxH800 analyzers. HbA1c was measured in EDTA blood using an International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) aligned TOSOH G8 ion exchange high performance liquid chromatography analyzers.
The scientists reported that the median (interquartile range) HbA1c was 41 (32–56) mmol/mol [5.9%] (5.1–7.3) versus 61 (52–70) mmol/mol [7.7 (6.9–8.6) %] respectively, in the diabetes with cirrhosis group versus the diabetes without cirrhosis group. The glucose concentrations were 8.4 (7.0–11.2) mmol/L versus 7.3 (5.2–11.5) mmol/L. HbA1c was depressed by 20 mmol/mol (1.8%) in 28 participants with cirrhosis but elevated by 28 mmol/mol (2.6%) in the participant with α‐1‐antitrypsin disorder. Those with cirrhosis and depressed HbA1c had fewer larger erythrocytes, and higher red cell distribution width and reticulocyte count. This was reflected in the positive association of glucose with mean cell volume and hemoglobin level and the negative association for HbA1c in the diabetes group with cirrhosis.
The authors concluded that cirrhosis of the liver affects the accuracy of HbA1c results, leading to unreliable estimates of blood glucose over the previous 2 to 3 months. Anemia in people with cirrhosis awaiting liver transplant is associated with altered red blood cell morphology. The study was originally published in the May 2019 issue of the journal Diabetic Medicine.
Related Links:
Queen Elizabeth Hospital
Glycated hemoglobin or HbA1c is now widely used for this purpose in primary care, resulting in a doubling of the number of HbA1c assessments requested, and a corresponding decrease in glucose measurement. Since 2014, the use of HbA1c testing has been included in the American Diabetes Association guidelines for the diagnosis of diabetes in hospital.
Scientists at the Queen Elizabeth Hospital (Birmingham, UK) and their colleagues collected HbA1c and random plasma glucose data for 125 people with diabetes without liver disease and for 29 people awaiting liver transplant with diabetes and cirrhosis. Cirrhosis was caused by non‐alcoholic fatty liver disease, hepatitis C, alcoholic liver disease, hereditary hemochromatosis, polycystic liver/kidneys, cryptogenic/non‐cirrhotic portal hypertension and α‐1‐antitrypsin‐related disease.
The team measured biochemical variables on the Roche c8000 analyzers and full blood count on Beckman DxH800 analyzers. HbA1c was measured in EDTA blood using an International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) aligned TOSOH G8 ion exchange high performance liquid chromatography analyzers.
The scientists reported that the median (interquartile range) HbA1c was 41 (32–56) mmol/mol [5.9%] (5.1–7.3) versus 61 (52–70) mmol/mol [7.7 (6.9–8.6) %] respectively, in the diabetes with cirrhosis group versus the diabetes without cirrhosis group. The glucose concentrations were 8.4 (7.0–11.2) mmol/L versus 7.3 (5.2–11.5) mmol/L. HbA1c was depressed by 20 mmol/mol (1.8%) in 28 participants with cirrhosis but elevated by 28 mmol/mol (2.6%) in the participant with α‐1‐antitrypsin disorder. Those with cirrhosis and depressed HbA1c had fewer larger erythrocytes, and higher red cell distribution width and reticulocyte count. This was reflected in the positive association of glucose with mean cell volume and hemoglobin level and the negative association for HbA1c in the diabetes group with cirrhosis.
The authors concluded that cirrhosis of the liver affects the accuracy of HbA1c results, leading to unreliable estimates of blood glucose over the previous 2 to 3 months. Anemia in people with cirrhosis awaiting liver transplant is associated with altered red blood cell morphology. The study was originally published in the May 2019 issue of the journal Diabetic Medicine.
Related Links:
Queen Elizabeth Hospital
Latest Hematology News
- First Point-of-Care Heparin Monitoring Test Provides Results in Under 15 Minutes
- New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
- Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
- WBC Count Could Predict Severity of COVID-19 Symptoms
- New Platelet Counting Technology to Help Labs Prevent Diagnosis Errors
- Streamlined Approach to Testing for Heparin-Induced Thrombocytopenia Improves Diagnostic Accuracy
- POC Hemostasis System Could Help Prevent Maternal Deaths
- New Test Assesses Oxygen Delivering Ability of Red Blood Cells by Measuring Their Shape
- Personalized CBC Testing Could Help Diagnose Early-Stage Diseases in Healthy Individuals
- Non-Invasive Test Solution Determines Fetal RhD Status from Maternal Plasma
- First-Of-Its-Kind Smartphone Technology Noninvasively Measures Blood Hemoglobin Levels at POC
- Next Gen CBC and Sepsis Diagnostic System Targets Faster, Earlier, Easier Results
- Newly Discovered Blood Group System to Help Identify and Treat Rare Patients
- Blood Platelet Score Detects Previously Unmeasured Risk of Heart Attack and Stroke
- Automated Benchtop System to Bring Blood Testing To Anyone, Anywhere
- New Hematology Analyzers Deliver Combined ESR and CBC/DIFF Results in 60 Seconds
Channels
Molecular Diagnostics
view channel
POC Oral Swab Test to Increase Chances of Pregnancy in IVF
Approximately 15% of couples of reproductive age experience involuntary childlessness. A significant reason for this is the growing trend of delaying family planning, a global shift that is expected to... Read more
Microbial Cell-Free DNA Test Accurately Identifies Pathogens Causing Pneumonia and Other Lung Infections
Bronchoalveolar lavage (BAL) is a commonly used procedure for diagnosing lung infections, especially in immunocompromised patients. However, standard tests often fail to pinpoint the exact pathogen, leading... Read moreHematology
view channel
First Point-of-Care Heparin Monitoring Test Provides Results in Under 15 Minutes
Heparin dosing requires careful management to avoid both bleeding and clotting complications. In high-risk situations like extracorporeal membrane oxygenation (ECMO), mortality rates can reach about 50%,... Read more
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read moreImmunology
view channel
Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more
Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
Chimeric antigen receptor (CAR) T-cell therapy has emerged as one of the most promising recent developments in the treatment of blood cancers. However, over half of non-Hodgkin lymphoma (NHL) patients... Read moreMicrobiology
view channel
New Blood Test Detects Up to Five Infectious Diseases at POC
Researchers have developed a prototype flow-through assay capable of detecting up to five different infections, with results that can be quickly analyzed and transmitted via a specialized smartphone app.... Read more
Molecular Stool Test Shows Potential for Diagnosing TB in Adults with HIV
Tuberculosis (TB), caused by the bacterium Mycobacterium tuberculosis, led to 1.25 million deaths in 2023, with 13% of those occurring in people living with HIV. The current primary diagnostic method for... Read morePathology
view channel
Groundbreaking Chest Pain Triage Algorithm to Transform Cardiac Care
Cardiovascular disease is responsible for a third of all deaths worldwide, and chest pain is the second most common reason for emergency department (ED) visits. With EDs often being some of the busiest... Read more
AI-Based Liquid Biopsy Approach to Revolutionize Brain Cancer Detection
Detecting brain cancers remains extremely challenging, with many patients only receiving a diagnosis at later stages after symptoms like headaches, seizures, or cognitive issues appear. Late-stage diagnoses... Read moreTechnology
view channel
Advanced Predictive Algorithms Identify Patients Having Undiagnosed Cancer
Two newly developed advanced predictive algorithms leverage a person’s health conditions and basic blood test results to accurately predict the likelihood of having an undiagnosed cancer, including ch... Read more
Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses
Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more
Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples
As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more
Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read moreIndustry
view channel
Qiagen Acquires NGS Analysis Software Company Genoox
QIAGEN (Venlo, the Netherlands) has signed a definitive agreement to acquire Genoox (Tel Aviv, Israel), a provider of artificial intelligence (AI)-powered software that enables clinical labs to scale and... Read more
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more