LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Sickle Cell Trait Confounds Blood Sugar Readings

By LabMedica International staff writers
Posted on 23 Feb 2017
Print article
Image: The G8 HPLC analyzer for HbA1c measurement (Photo courtesy of Tosoh Bioscience).
Image: The G8 HPLC analyzer for HbA1c measurement (Photo courtesy of Tosoh Bioscience).
Sickle cell trait (SCT) is a genetic hemoglobin variant found in 8% to 10% of African-Americans and it occurs in people with one copy of the mutation because if they had two copies, that would result in sickle cell disease.

Hemoglobin A1c (HbA1c) is a common blood biomarker used to measure blood sugar over time, but it may not perform as accurately among African-Americans with sickle cell trait and could be leading to a systemic underestimation of blood sugar control among that population.

A team of scientists led by those at the Brown University School of Public Health performed a retrospective cohort study on data from two studies and the analytic sample included 4,620 participants (mean age, 52.3 ±11.8 years; 2,835 women (61.3%); 367 (7.9%) with SCT) with 9,062 concurrent measures of fasting glucose and HbA1c. Analysis of the primary outcome was conducted using generalized estimating equations (GEE) to examine the association of SCT with HbA1c levels, controlling for fasting or 2-hour glucose measures.

Among all the patients included in the analysis, HbA1c readings came from either of two widely used, clinically accepted assays made by Tosoh Bioscience Inc. that rely on a process called high-performance liquid chromatography. In addition to those measures, the scientists also compared fasting and two-hour blood glucose and statistically controlled for demographic and medical factors, such as gender, age, body-mass index and whether diabetes had already been diagnosed and whether it was being treated.

The team found that using standard clinical HbA1c cutoffs resulted in identifying 40% fewer potential cases of prediabetes and 48% fewer potential cases of diabetes in people with SCT than in people without SCT. Meanwhile, when the scientists used other blood glucose measures as the diagnostic criteria, they found no significant difference in the likelihood of diabetes and prediabetes among patients with or without SCT. Current diagnostic thresholds for HbA1C are greater than 5.7% for prediabetes and greater than 6.5% for diabetes.

The authors of the study therefore recommend that practitioners following African-American patients whose HbA1c levels are within 0.3 percentage points of a diagnostic cutoff also consider using additional blood glucose measures. Gregory A.Wellenius, ScD, an associate professor of epidemiology and co-author of the study said, “The strengths of the study are that it's the largest sample size ever used, it's across two different studies with somewhat different populations, and it's a more thorough evaluation than prior studies.” The study was published on February 7, 2017, in the Journal of the American Medical Association (JAMA).

Gold Member
Chagas Disease Test
CHAGAS Cassette
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
ACTH Assay
ACTH ELISA
New
Dermatophytosis Rapid Diagnostic Kit
StrongStep Dermatophytosis Diagnostic Kit

Print article

Channels

Molecular Diagnostics

view channel
Image: The Mirvie RNA platform predicts pregnancy complications months before they occur using a simple blood test (Photo courtesy of Mirvie)

RNA-Based Blood Test Detects Preeclampsia Risk Months Before Symptoms

Preeclampsia remains a major cause of maternal morbidity and mortality, as well as preterm births. Despite current guidelines that aim to identify pregnant women at increased risk of preeclampsia using... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Deliver Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: Schematic illustration of the chip (Photo courtesy of Biosensors and Bioelectronics, DOI: https://doi.org/10.1016/j.bios.2025.117401)

Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples

Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.