LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Rapid Influenza Detection Tests Evaluated for Viral Antigens

By LabMedica International staff writers
Posted on 01 Dec 2016
Print article
Image: The rapid influenza detection test Quick Navi-Flu (Photo courtesy of Otsuka Pharmaceutical).
Image: The rapid influenza detection test Quick Navi-Flu (Photo courtesy of Otsuka Pharmaceutical).
Reverse transcriptase polymerase chain reaction (RT-PCR) has a high sensitivity and a high specificity for the rapid diagnosis of influenza infection; however, the high cost and necessity of specialized equipment have limited the use of RT-PCR in the clinical setting.

Immunochromatography-based rapid influenza virus antigen tests, in which the result appears within 15 minutes, have been used for the early diagnosis of influenza in the clinical setting in Japan. Rapid influenza detection tests (RIDTs) equipped with an instrument-based fluorescence reader system has recently been developed, and their performances have been validated.

Scientists at the Tokyo Medical University (Japan) enrolled a total of 123 participants consisting of 53 men (43.1%) and 70 women (56.9%). The mean age of the patients was 35.1 years (range 20–74 years). The median time to visiting the hospital after illness onset was 26.2 hours (ranging from a few hours to five days). The study was performed from December 2013 to March 2014. Nasopharyngeal swab specimens were collected by performing original swab samplings, which were composed of three swabs.

After collecting the specimens from the participants, the swabs were separated for the tests. One swab was transferred in viral transport medium for virus isolation; the other two swabs were used for the rapid influenza virus antigen detection tests. In this study, the new RIDT GOLD SIGN FLU (Morinaga Milk Industry Co., Ltd, Tokyo, Japan) and Institute of Immunology Co., Ltd, Tokyo, Japan) and the existing immunochromatography-based RIDT Quick Navi-Flu (Otsuka Pharmaceutical Co., Ltd, Tokyo, Japan) were evaluated as compared to viral isolation as the gold standard method.

Among the 123 patients from whom nasopharyngeal swab specimens were collected, 59 tested positive by viral isolation as the gold standard method, 38 with influenza A; 21 with influenza B. For GOLD SIGN FLU, the sensitivities were 73.7% and 81.0%, and the specificities were 97.6% and 98.0% for influenza A and B, respectively. For Quick Navi-Flu, the sensitivities were 86.8% and 85.7%, and the specificities were 98.8% and 100% for influenza A and B, respectively. The time to the appearance of the line on the test strip was less than three minutes for influenza A and less than two minutes for influenza B with both RIDTs in more than 90% of cases.

The authors concluded that GOLD SIGN FLU was useful for diagnosing influenza A, and the result was readily available for influenza B particularly among adult patients. Quick Navi-Flu showed better sensitivities and specificities than GOLD SIGN FLU. The study was published in the November 2016 issue of the International Journal of Infectious Diseases.

Related Links:
Tokyo Medical University
Morinaga Milk Industry
Institute of Immunology
Otsuka Pharmaceutical
New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Auto Clinical Chemistry Analyzer
cobas c 703
New
Multi-Function Pipetting Platform
apricot PP5

Print article

Channels

Molecular Diagnostics

view channel
Image: The Mirvie RNA platform predicts pregnancy complications months before they occur using a simple blood test (Photo courtesy of Mirvie)

RNA-Based Blood Test Detects Preeclampsia Risk Months Before Symptoms

Preeclampsia remains a major cause of maternal morbidity and mortality, as well as preterm births. Despite current guidelines that aim to identify pregnant women at increased risk of preeclampsia using... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Schematic illustration of the chip (Photo courtesy of Biosensors and Bioelectronics, DOI: https://doi.org/10.1016/j.bios.2025.117401)

Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples

Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.