Commercial Molecular Assay Validated for Dengue Virus Outbreak
By LabMedica International staff writers Posted on 28 Oct 2016 |

Image: The LabTurbo 48 compact system can fully automate DNA/RNA extraction of up to 48 samples in 90 minutes (Photo courtesy of Taigen Bioscience).
Dengue virus (DENV) is a member of the viral genus Flavivirus (family Flaviviridae) that is transmitted by mosquitos, causing endemic and epidemic outbreaks in tropical and subtropical areas.
Accurate, rapid, and early diagnosis of DENV infections is important for public health and optimal clinical care; however, the gold standard method of cell culture-dependent isolation of DENV during the acute phase of infection is time-consuming and cumbersome.
Medical scientists at the National Cheng Kung University (Tainan, Taiwan) collected serum samples from patients with suspected DENV infection between July and November 2015. Sera from patients with suspected DENV infection were screened using the one-step immunochromatographic SD BIOLINE Dengue DuoDengue NS1 Ag + Ab Combo assay. This rapid assay contains two test devices, which can simultaneously detect the levels of nonstructural protein 1(NS1) antigen, and immunoglobulin M (IgM) and IgG in a sample, respectively, within 15 minutes.
Viral ribonucleic acid (RNA) was extracted from serum samples and an extraction control sample using a QAIamp viral RNA mini kit or the automated extraction system LabTurbo Virus mini Kit in LabTurbo 48 Compact System. Quantitative real-time polymerase chain reaction (qRT-PCR) analysis of viral loads was performed using LightMix dengue virus EC kit, which is capable of identifying all four dengue serotypes.
A total of 8,989, 8,954, and 1,581 samples were subjected to NS1 antigen detection, IgM and IgG detection, and LightMix assays, respectively. The LightMix assay yielded a linear curve for viral loads (VL) between 102 and 106 copies/reaction, and the minimum detection limits for DENV serotype 1 (DENV1) and DENV2, DENV3, and DENV4 were 1, 10, and 100 focus forming units (FFU)/mL, respectively. There was 88.9% concordance between the results obtained using the NS1 antigen combo kit and by LightMix analysis, and the diagnostic sensitivity and specificity of the two methods were 89.4% and 100%, and 84.7% and 100%, respectively.
The authors concluded that the LightMix assay was effective for early diagnosis of DENV infection. The data indicated that high viral loads during primary infection in elderly patients may be a positive predictor for severe illness, and may contribute to high mortality rates. The study was published on October 12, 2016, in the journal Public Library of Science Neglected Tropical Diseases.
Related Links:
National Cheng Kung University
Accurate, rapid, and early diagnosis of DENV infections is important for public health and optimal clinical care; however, the gold standard method of cell culture-dependent isolation of DENV during the acute phase of infection is time-consuming and cumbersome.
Medical scientists at the National Cheng Kung University (Tainan, Taiwan) collected serum samples from patients with suspected DENV infection between July and November 2015. Sera from patients with suspected DENV infection were screened using the one-step immunochromatographic SD BIOLINE Dengue DuoDengue NS1 Ag + Ab Combo assay. This rapid assay contains two test devices, which can simultaneously detect the levels of nonstructural protein 1(NS1) antigen, and immunoglobulin M (IgM) and IgG in a sample, respectively, within 15 minutes.
Viral ribonucleic acid (RNA) was extracted from serum samples and an extraction control sample using a QAIamp viral RNA mini kit or the automated extraction system LabTurbo Virus mini Kit in LabTurbo 48 Compact System. Quantitative real-time polymerase chain reaction (qRT-PCR) analysis of viral loads was performed using LightMix dengue virus EC kit, which is capable of identifying all four dengue serotypes.
A total of 8,989, 8,954, and 1,581 samples were subjected to NS1 antigen detection, IgM and IgG detection, and LightMix assays, respectively. The LightMix assay yielded a linear curve for viral loads (VL) between 102 and 106 copies/reaction, and the minimum detection limits for DENV serotype 1 (DENV1) and DENV2, DENV3, and DENV4 were 1, 10, and 100 focus forming units (FFU)/mL, respectively. There was 88.9% concordance between the results obtained using the NS1 antigen combo kit and by LightMix analysis, and the diagnostic sensitivity and specificity of the two methods were 89.4% and 100%, and 84.7% and 100%, respectively.
The authors concluded that the LightMix assay was effective for early diagnosis of DENV infection. The data indicated that high viral loads during primary infection in elderly patients may be a positive predictor for severe illness, and may contribute to high mortality rates. The study was published on October 12, 2016, in the journal Public Library of Science Neglected Tropical Diseases.
Related Links:
National Cheng Kung University
Latest Microbiology News
- Handheld Device Deliver Low-Cost TB Results in Less Than One Hour
- New AI-Based Method Improves Diagnosis of Drug-Resistant Infections
- Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours
- Innovative ID/AST System to Help Diagnose Infectious Diseases and Combat AMR
- Gastrointestinal Panel Delivers Rapid Detection of Five Common Bacterial Pathogens for Outpatient Use
- Rapid PCR Testing in ICU Improves Antibiotic Stewardship
- Unique Genetic Signature Predicts Drug Resistance in Bacteria
- Unique Barcoding System Tracks Pneumonia-Causing Bacteria as They Infect Blood Stream
- Rapid Sepsis Diagnostic Test Demonstrates Improved Patient Care and Cost Savings in Hospital Application
- Rapid Diagnostic System to Detect Neonatal Sepsis Within Hours
- Novel Test to Diagnose Bacterial Pneumonia Directly from Whole Blood
- Interferon-γ Release Assay Effective in Patients with COPD Complicated with Pulmonary Tuberculosis
- New Point of Care Tests to Help Reduce Overuse of Antibiotics
- 30-Minute Sepsis Test Differentiates Bacterial Infections, Viral Infections, and Noninfectious Disease
- CRISPR-TB Blood Test to Enable Early Disease Diagnosis and Public Screening
- Syndromic Panel Provides Fast Answers for Outpatient Diagnosis of Gastrointestinal Conditions
Channels
Clinical Chemistry
view channel
Carbon Nanotubes Help Build Highly Accurate Sensors for Continuous Health Monitoring
Current sensors can measure various health indicators, such as blood glucose levels, in the body. However, there is a need to develop more accurate and sensitive sensor materials that can detect lower... Read more
Paper-Based Device Boosts HIV Test Accuracy from Dried Blood Samples
In regions where access to clinics for routine blood tests presents financial and logistical obstacles, HIV patients are increasingly able to collect and send a drop of blood using paper-based devices... Read moreMolecular Diagnostics
view channel
RNA-Based Blood Test Detects Preeclampsia Risk Months Before Symptoms
Preeclampsia remains a major cause of maternal morbidity and mortality, as well as preterm births. Despite current guidelines that aim to identify pregnant women at increased risk of preeclampsia using... Read more
First Of Its Kind Test Uses microRNAs to Predict Toxicity from Cancer Therapy
Many men with early-stage prostate cancer receive stereotactic body radiotherapy (SBRT), a highly precise form of radiation treatment that is completed in just five sessions. Compared to traditional radiation,... Read more
Novel Cell-Based Assay Provides Sensitive and Specific Autoantibody Detection in Demyelination
Anti-myelin-associated glycoprotein (MAG) antibodies serve as markers for an autoimmune demyelinating disorder that affects the peripheral nervous system, leading to sensory impairment. Anti-MAG-IgM antibodies... Read moreHematology
view channel
New Scoring System Predicts Risk of Developing Cancer from Common Blood Disorder
Clonal cytopenia of undetermined significance (CCUS) is a blood disorder commonly found in older adults, characterized by mutations in blood cells and a low blood count, but without any obvious cause or... Read more
Non-Invasive Prenatal Test for Fetal RhD Status Demonstrates 100% Accuracy
In the United States, approximately 15% of pregnant individuals are RhD-negative. However, in about 40% of these cases, the fetus is also RhD-negative, making the administration of RhoGAM unnecessary.... Read moreImmunology
view channel
Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer
Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more
Machine Learning-Enabled Blood Test Predicts Immunotherapy Response in Lymphoma Patients
Chimeric antigen receptor (CAR) T-cell therapy has emerged as one of the most promising recent developments in the treatment of blood cancers. However, over half of non-Hodgkin lymphoma (NHL) patients... Read morePathology
view channel
Advanced Imaging Reveals Mechanisms Causing Autoimmune Disease
Myasthenia gravis, an autoimmune disease, leads to muscle weakness that can affect a range of muscles, including those needed for basic actions like blinking, smiling, or moving. Researchers have long... Read more
AI Model Effectively Predicts Patient Outcomes in Common Lung Cancer Type
Lung adenocarcinoma, the most common form of non-small cell lung cancer (NSCLC), typically adopts one of six distinct growth patterns, often combining multiple patterns within a single tumor.... Read moreTechnology
view channel
Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples
Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more
Innovative, Label-Free Ratiometric Fluorosensor Enables More Sensitive Viral RNA Detection
Viruses present a major global health risk, as demonstrated by recent pandemics, making early detection and identification essential for preventing new outbreaks. While traditional detection methods are... Read moreIndustry
view channel
Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions
Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Grifols and Tecan’s IBL Collaborate on Advanced Biomarker Panels
Grifols (Barcelona, Spain), one of the world’s leading producers of plasma-derived medicines and innovative diagnostic solutions, is expanding its offer in clinical diagnostics through a strategic partnership... Read more