LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Electrostatic Dissipative Feature Augments New Line of Ductless Fume Hoods

By LabMedica International staff writers
Posted on 13 Aug 2013
Print article
Image: Aura ESD ductless fume hoods are self-contained, filtered enclosures that remove hazardous fumes, vapors and particles from virtually any laboratory application. Unlike traditional fume hoods, there are no installation costs and no ductwork is needed (Photo courtesy of Mystaire Misonix).
Image: Aura ESD ductless fume hoods are self-contained, filtered enclosures that remove hazardous fumes, vapors and particles from virtually any laboratory application. Unlike traditional fume hoods, there are no installation costs and no ductwork is needed (Photo courtesy of Mystaire Misonix).
Image: Aura - how it works: Laboratory air enters Aura at ″A″ and is combined with contaminated air at ″B″ before entering into filtration at ″C.″ Filtration at ″C″ can be gas phase, mechanical, or both depending on the application. At ″D,″ air is pulled into the plenum area. The gas detector and test port sampling tubing are located in this area. At ″E,″ optional safety filtration can be installed before contaminant-free air is returned to the laboratory space at ″F″ (Photo courtesy of Mystaire Misonix).
Image: Aura - how it works: Laboratory air enters Aura at ″A″ and is combined with contaminated air at ″B″ before entering into filtration at ″C.″ Filtration at ″C″ can be gas phase, mechanical, or both depending on the application. At ″D,″ air is pulled into the plenum area. The gas detector and test port sampling tubing are located in this area. At ″E,″ optional safety filtration can be installed before contaminant-free air is returned to the laboratory space at ″F″ (Photo courtesy of Mystaire Misonix).
A new line of fume hoods that promises laboratory workers superior protection against buildup of toxic fumes has been combined with electrostatic dissipative features to prevent static buildup and discharge.

Aura ductless fume hoods manufactured by Mystaire Misonix (Creedmoor, NC, USA) are self-contained, filtered enclosures that remove hazardous fumes, vapors, and particles from virtually any laboratory application. Unlike traditional fume hoods, there are no installation costs and no ductwork is needed. The new Aura ESD line of hoods adds an electrostatic dissipation feature to the state-of-the art Aura line.

Each Aura ductless fume hood has advanced safety monitoring and controls including the EverSafe II microprocessor safety controller, which monitors and adjusts fume hood face velocity to a user-preset value. EverSafe II maintains face velocity at the proper rate for containment of potentially toxic gases and vapors.

The US made Aura fume hoods, which are available in 72.6 centimeter, 106.68 centimeter, and 137.16-centimeter widths have been ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) 110 tested and provide excellent containment from toxic fumes and vapors. The Filtrak positive filter sealing system installed in each Aura ductless hood is a cam-driven filter sealing system with a built-in filter position indicator and an alert that informs the user if the filtration bed is not properly sealed. The Filtrak system enables safe and easy filter maintenance and replacement.

Related Links:
Mystaire Misonix


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more