Membrane-Based Microplate Inserts Allow Real-Time Studies of Cell-to-Cell Interactions and Communication

By LabMedica International staff writers
Posted on 26 Jun 2012
Print article
Image: The E-Plate VIEW Insert 96 (Photo courtesy of Roche).
Image: The E-Plate VIEW Insert 96 (Photo courtesy of Roche).
A novel membrane-based insert for 16-well and 96-well microplates enables life science researchers to study indirect cell-cell interactions and communication in real-time and without fluorescent labeling.

The Roche (Basel, Switzerland) E-Plate Insert 16 and E-Plate Insert 96 were designed specifically for use with Roche’s line of xCELLigence Instruments.

The xCELLigence System allows for real-time, label-free dynamic monitoring of cellular phenotypic changes by measuring electrical impedance. The system measures impedance using interdigitated microelectrodes integrated into the bottom of each well of special tissue culture E-Plates. Impedance measurements are displayed as Cell Index (CI) values, providing quantitative information about the biological status of the cells, including cell number, cell viability and cell morphology.

Electronic impedance of the microelectrodes is mainly determined by the ionic environment in the regions around the electrodes and can be monitored as baseline impedance by applying an electrical field to the electrodes. The presence of the cells will affect the local ionic environment at the electrode/solution interface, leading to an increase in the electrode impedance. The more cells there are on the electrodes, the larger the increases in electrode impedance. In addition, the impedance change depends on the quality of the cell interaction with the electrodes. For example, increased cell adhesion or spreading will lead to a larger change in electrode impedance. Thus, electrode impedance, which is displayed as cell index (CI) values, can be used to monitor cell viability, number, morphology, and adhesion degree in a number of cell-based assays.

CI was derived as a relative change in measured electrical impedance to represent cell status. This means that when cells are not present or are not well adhered on the electrodes, the CI is zero.

Under the same physiological conditions, when more cells are attached on the electrodes, then the CI values are larger. Thus, CI is a quantitative measure of cell number present in a well of the microplate. Additionally, change in a cell status, such as cell morphology, cell adhesion, or cell viability will lead to a change in CI.

In addition to monitoring cell viability, the xCELLigence System is able to identify culture wells with inappropriate cell numbers at the beginning of the assay, thus minimizing the role of cell seeding and culture plate-edge artifacts during data analysis.

The new E-Plate inserts allow co-cultivation of two different cell types, which is an important technique for investigating cell-cell interactions and communication. Investigators at INRS-Institut Armand-Frappier (Laval, Canada) used E-Plate Inserts to test the behavior of BeWo human placental choriocarcinoma cells in co-culture with H295R human adrenocortical carcinoma cells.

“Using the E-Plate Insert in our co-culture experiments requires fewer manipulations and allows us to perform several experiments simultaneously - hormone measurements, signaling pathway analysis, real-time monitoring of biochemical and morphological differentiation of the cells,” said Dr. Thomas Sanderson, associate professor of toxicology at INRS-Institut Armand-Frappier .

Related Links:

INRS-Institut Armand-Frappier
Roche


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more