Arterial Gas Analyzer and Autoanalyzer Compared for Electrolytes

By LabMedica International staff writers
Posted on 28 Mar 2013
Print article
Electrolyte values are measured in most critically ill intensive care unit (ICU) patients using both an arterial blood gas analyzer (ABG) and a central laboratory autoanalyzer (AA).

Data on sodium and potassium ion concentrations in ICU patients have been examined to see whether the electrolyte levels assessed by the ABG and the AA are equivalent and reliable.

Scientists at the Sevket Yilmaz Education and Research Hospital (Bursa, Turkey) retrospectively studied patients hospitalized in the ICU between July and August 2011. They identified 84 instances, of 1,105 patient blood gas samples analyzed, in which arterial and venous samples were collected simultaneously and sodium (Na+) and (K+) were measured using two methods.

In the ICU, arterial blood samples were collected in heparinized blood-gas syringes and analyzed using the benchtop pHOx Stat Profile Plus L blood–gas analyzer (Nova Biomedical; Waltham MA, USA) which employs direct ion-specific electrode (ISE) technology. Another sample was drawn, at the same time, from the same arterial sampling point, using a vacuum technique featuring clot-activating tubes. These samples were sent, pneumatically sealed, to the central laboratory, where serum Na+ and K+ concentrations were analyzed via indirect ISE on a Modular ISE900 auto-analyzer (Roche Diagnostics; Mannheim, Germany).

The mean sodium concentration was 138.mmol/L (standard deviation, SD ±10.2 mmol/L) using the ABG and 143.0 mmol/L (SD ±10.5 mmol/L) using the AA, which was statistically different. The mean potassium level was 3.5mmol/L (SD ± 0.9 mmol/L) using the ABG and 3.7 mmol/L (SD ± 1.0 mmol/L) using the AA which was also significantly different. The extent of interanalyzer agreement was unacceptable for both K+ and Na+. The between-day imprecision of both instruments (AA and ABG) was small and lacked clinical significance when compared with analytical performance indicators based on biological variation.

The authors concluded that their study illustrates the importance of determining the concordance, for each individual hospital, of electrolyte values obtained by ABG and those obtained in the central laboratory. As instrument type and calibration methods may differ among hospitals, it is important that each center conducts an in-house study as in their study the ABG and AA do not yield equivalent Na+ and K+ data. The study was published on August 3, 2012, in the BioMed Central journal BMC Anesthesiology.

Related Links:

Sevket Yilmaz Education and Research Hospital
Nova Biomedical
Roche



Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Vaginitis Test
Allplex Vaginitis Screening Assay
New
Piezoelectric Micropump
Disc Pump

Print article

Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The AI-based method can more accurately detect antibiotic resistance in deadly bacteria such as tuberculosis and staph (Photo courtesy of Adobe Stock)

New AI-Based Method Improves Diagnosis of Drug-Resistant Infections

Drug-resistant infections, particularly those caused by deadly bacteria like tuberculosis and staphylococcus, are rapidly emerging as a global health emergency. These infections are more difficult to treat,... Read more

Technology

view channel
Image: Pictorial representation of the working principle of a functionalized Carbon Dots CDs and EB based Func sensor (Photo courtesy of Toppari/University of Jyväskylä)

Innovative, Label-Free Ratiometric Fluorosensor Enables More Sensitive Viral RNA Detection

Viruses present a major global health risk, as demonstrated by recent pandemics, making early detection and identification essential for preventing new outbreaks. While traditional detection methods are... Read more
Sekisui Diagnostics UK Ltd.