We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Newest Combination HIV Antigen-Antibody Assay Evaluated

By LabMedica International staff writers
Posted on 27 Feb 2013
Print article
Diagnostic tests capable of early detection represent the most effective means of preventing transmission of human immunodeficiency virus (HIV).

A fourth-generation antigen-antibody combination assay has been developed to allow earlier detection of seroconversion, and has increased sensitivity and improved specificity.

Scientists at the Innsbruck University Hospital (Austria) determined how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors.

The study was carried out at 12 centers in Europe, Thailand, and Australia. The Elecsys HIV combi PT assay (Roche Diagnostics; Penzberg, Germany) is performed according to the sandwich principle. The results are automatically determined by the Elecsys software that compares the signal produced from the sample with the cutoff value obtained during system calibration. The total assay time is 27 minutes.

A total of 14 seroconversion panels, comprising 135 samples were analyzed to determine how soon after a positive polymerase chain reaction (PCR) result the immunoassays could detect HIV infection. Samples were identified as positive by the Elecsys assay 4.9 days after a positive PCR result that had been predetermined, which was earlier than the 5.3 to 7.1days observed with other comparable assays. The analytical sensitivity of the Elecsys HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the other assays.

In addition, the assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. The assay demonstrated 100% specificity in patients with infections other than HIV, such as Cytomegalovirus or herpes simplex virus. Overall, the specificity of the Elecsys assay was 99.88% using samples from blood donors and 99.81% when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys HIV combi PT assay has been granted the European Conformity (CE) marking and is now available for use in laboratory-based testing. The study was published in the February 2013 issue of the journal Medical Microbiology and Immunology.

Related Links:
Innsbruck University Hospital
Roche Diagnostics

Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
Total Hemoglobin Monitoring System
GREENCARE Hb
New
Biological Indicator Vials
BI-O.K.

Print article

Channels

Clinical Chemistry

view channel
Image: The study demonstrated that electric-field molecular fingerprinting can probe cancer (Photo courtesy of ACS Central Science, 2025, 10.1021/acscentsci.4c02164)

New Method Uses Pulsed Infrared Light to Find Cancer's 'Fingerprints' In Blood Plasma

Cancer diagnoses have traditionally relied on invasive or time-consuming procedures like tissue biopsies. Now, new research published in ACS Central Science introduces a method that utilizes pulsed infrared... Read more

Molecular Diagnostics

view channel
Image: The test monitors blood levels of DNA fragments released by dying tumor cells (Photo courtesy of 123RF)

Gene-Based Blood Test Accurately Predicts Tumor Recurrence of Advanced Skin Cancer

Melanoma, an aggressive form of skin cancer, becomes extremely difficult to treat once it spreads to other parts of the body. For patients with metastatic melanoma tumors that cannot be surgically removed... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Schematic illustration of the chip (Photo courtesy of Biosensors and Bioelectronics, DOI: https://doi.org/10.1016/j.bios.2025.117401)

Pain-On-A-Chip Microfluidic Device Determines Types of Chronic Pain from Blood Samples

Chronic pain is a widespread condition that remains difficult to manage, and existing clinical methods for its treatment rely largely on self-reporting, which can be subjective and especially problematic... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.