D-Serine Clearance Evaluates Precise Measurement of Kidney Function

By LabMedica International staff writers
Posted on 21 Dec 2021
Print article
Image: D-Serine is useful for the measurement of glomerular filtration rate (GFR). The clearance of D-serine has an advantage of lower bias against GFR compared to that with the creatinine clearance. Combinational clearance measurement of D-serine and creatinine can serve as a measure of GFR with precision and low bias (Photo courtesy of Tomonori Kimura, MD, PhD)
Image: D-Serine is useful for the measurement of glomerular filtration rate (GFR). The clearance of D-serine has an advantage of lower bias against GFR compared to that with the creatinine clearance. Combinational clearance measurement of D-serine and creatinine can serve as a measure of GFR with precision and low bias (Photo courtesy of Tomonori Kimura, MD, PhD)
Evaluation of kidney function is essential in daily clinical practice. The measured glomerular filtration rate (mGFR) using exogenous inulin has been considered as the gold standard of kidney function, though this procedure is labor intensive, time consuming, and expensive.

D-Serine is a candidate biomarker of kidney function. D-Serine circulates the bloodstream in the body and is delivered to the kidney. D-Serine is then filtrated through the glomerulus and excreted in the urine. When kidney function is impaired, the urinary excretion of D-serine decreases, and its blood level increases.

Medical Scientists at the Osaka University (Osaka, Japan) and their colleagues carried out a cross-sectional observational study of 200 living kidney transplant donors and recipients enrolled between July 2019 and December 2020, for whom GFR was measured by clearance of inulin (C-in).

The clearance of D-serine (C-DSer) was calculated based on blood and urine levels of D-serine, as measured by two-dimensional high-performance liquid chromatography. Analytical performance was assessed by calculating biases. Utilizing data from 129 participants, the team developed equations for C-in based on C-DSer and C-cre using a linear regression model, and the performance was validated in 68 participants. Creatinine in serum and urine was measured enzymatically (Determiner L CRE, Hitachi Chemical, Tokyo, Japan), and serum cystatin C (sCys) was measured using an immunological turbid metric assay (Nescoat GC Cystatin C, Alfresa Pharma, Osaka, Japan).

The investigators reported that in the overall cohort, the mean values of serum creatinine, cystatin C, and plasma D-serine were 0.86 mg/dL, 1.1 mg/L, and 2.3 μM, respectively. The mean clearances of inulin, creatinine, and D-serine were 66.7, 98.2, and 55.7mL per minutes per 1.73m2 of body surface area, respectively. The levels and clearances of D-serine in plasma and serum were almost identical and so they used plasma level of D-serine in the analysis. In the total cohort population, C-DSer was significantly and strongly correlated with C-in (R = 0.91), like C-cre (R = 0.93). Remarkably, the clearance of D-serine agreed well with GFR. The low bias as a measure of GFR was an advantage for the D-serine clearance. The degree of bias against GFR was smaller than that of the creatinine clearance. Additionally, the combinational analysis of clearances of D-serine and creatinine could measure GFR with high performance.

Tomonori Kimura, MD, PhD, the senior author of the study, said, “D-Serine turned out to be of great clinical importance. D-Serine may solve the problem of kidney disease with more than 800 million patients in the world. Measuring D-serine is applicable in a wide range of clinical fields and for drug development.”

The authors concluded that the combination of C-DSer and C-cre can measure the GFR with precision and minor biases. The current method using endogenous molecules may reduce clinical burdens for measuring GFR. The new method is precise across the tested range of GFR and has the potential to facilitate key clinical decisions in various clinical situations. The study was published on December 4, 2021 in the journal EClinicalMedicine.

Related Links:
Osaka University
Hitachi Chemical
Alfresa Pharma


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more